Contamination Resistant Three Electrode Total Chlorine Sensor For Direct Drinking Water Conductivity 10μS/Cm
|
|
Contamination Resistant Three Electrode Total Chlorine Sensor For Direct Drinking Water (Conductivity > 10μS/Cm).
Total chlorine refers to the sum of free chlorine and combined chlorine in the water. Free chlorine is chlorine that is not bound to organic or inorganic substances, usually in the form of free chlorine, such as chlorine gas or hypochlorite ions. Combined chlorine refers to compounds formed by combining chlorine with organic or inorganic substances, such as chloramine compounds.
Disinfection water quality control: Chloride is one of the most commonly used water treatment disinfectants. It is used to kill microorganisms in water and ensure the health and safety of drinking water and swimming pool water. Therefore, understanding the total chlorine content in water is the key to ensuring disinfection effectiveness.
Water quality safety monitoring: Total chlorine content is an indicator of water quality safety. Too high or too low total chlorine content may cause water quality problems. For example, too high a content may produce odor and taste, or even harmful substances, while too low a content may not be enough to kill pathogenic microorganisms in the water.
Environmental protection: Monitoring total chlorine content helps to understand the discharge of chloride in water bodies and prevent excessive chloride discharge from affecting the aquatic ecosystem.
Regular measurement of total chlorine levels is critical to maintaining water safety, protecting public health, and protecting the environment.
DCP4.0MA Total chlorine sensor Three-electrode system, used for drinking water, swimming pool water, service water, process water, sea water and salt water, direct drinking water (conductivity not less than 10μs/cm), medical sewage, pH 4~12, greatly reducing dependence on pH value. Resistant to pollution, low conductivity, almost no maintenance required, optional range 0~2/5/10/20/50ppm
Areas of application: Swimming pool water, drinking water, sea water, brine (15% NaCl) Surfactants (tensides) are partially tolerated. Scope of supply: CP4 sensor, membrane cap, electrolyte Specifications
Spare parts
CP4.0 (digital output, digital internal signal processing) - The power supply is galvanically isolated inside of the sensor. - The output signal is galvanically isolated too, that means potential-free.
(Subject to technical changes!)
CP4.0 4-20 mA (analog output, analog internal signal processing) A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation. Electrical connection: 2 pole terminal clamp
(Subject to technical changes!)
Electrical connection: 5 pole M12 plug-on flange
(Subject to technical changes!) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: Contamination Resistant Total Chlorine Sensor Three Electrode Total Chlorine Sensor Direct Drinking Water Total Chlorine Sensor | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Film Coating Three Electrode Total Chlorine Sensor For Seawater And Ballast Water |
|
Contamination Resistant Three Electrode Total Chlorine Sensor For Direct Drinking Water Conductivity 10μS/Cm |
|
Contamination Resistant Low Conductivity Three Probe For Sea Water Brine And Medical Wastewater |
|
Contamination Resistant Low Conductivity Three Electrode Total Chlorine Probe For Service Water Or Process Water |
|
Contamination Resistant Low Conductivity Three Electrode Total Chlorine Sensor For Drinking Water Or Swimming Pool |
|
4 - 20MA Residual Chlorine Sensor CS4 |