Contamination Resistant Low Conductivity Three Electrode Total Chlorine Probe For Service Water Or Process Water
|
|
Contamination Resistant Low Conductivity Three Electrode Total Chlorine Probe For Service Water Or Process Water
The three-electrode membrane total chlorine sensor is mainly used to measure the total chlorine content in water samples. Total chlorine refers to the sum of free chlorine and combined chlorine in water, and is usually used to disinfect water sources and water treatment processes. Therefore, the main measurement content of this sensor is the concentration of total chlorine in the water sample.
The DCP4.0MA total chlorine electrode indirectly measures the total chlorine content by measuring the concentration of chloride ions in the water sample. It uses a working electrode covered with a chloride ion selective sensing membrane to react with chloride ions in the water sample to produce a charge change, and then determines the concentration of chloride ions through current measurement between the electrodes to obtain the total chlorine content.
DCP4.0MA Total Chlorine Probe can provide real-time and accurate total chlorine concentration data to help water treatment plants, swimming pools, drinking water supply systems and other places monitor water quality, promptly detect problems in the pollution or disinfection process, and take necessary measures to Protect public health and water resources.
DCP4.0MA Total chlorine sensor Three-electrode system, used for drinking water, swimming pool water, service water, process water, sea water and salt water, direct drinking water (conductivity not less than 10μs/cm), medical sewage, pH 4~12, greatly reducing dependence on pH value. Resistant to pollution, low conductivity, almost no maintenance required, optional range 0~2/5/10/20/50ppm
Areas of application: Swimming pool water, drinking water, sea water, brine (15% NaCl) Surfactants (tensides) are partially tolerated. Scope of supply: CP4 sensor, membrane cap, electrolyte Specifications
Spare parts
CP4.0 (digital output, digital internal signal processing) - The power supply is galvanically isolated inside of the sensor. - The output signal is galvanically isolated too, that means potential-free.
(Subject to technical changes!)
CP4.0 4-20 mA (analog output, analog internal signal processing) A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation. Electrical connection: 2 pole terminal clamp
(Subject to technical changes!)
Electrical connection: 5 pole M12 plug-on flange
(Subject to technical changes!) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: Process Water Total Chlorine Probe Contamination Resistant Total Chlorine Probe Service Water Total Chlorine Probe | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Film Coating Three Electrode Total Chlorine Sensor For Seawater And Ballast Water |
|
Contamination Resistant Three Electrode Total Chlorine Sensor For Direct Drinking Water Conductivity 10μS/Cm |
|
Contamination Resistant Low Conductivity Three Probe For Sea Water Brine And Medical Wastewater |
|
Contamination Resistant Low Conductivity Three Electrode Total Chlorine Probe For Service Water Or Process Water |
|
Contamination Resistant Low Conductivity Three Electrode Total Chlorine Sensor For Drinking Water Or Swimming Pool |
|
4 - 20MA Residual Chlorine Sensor CS4 |