Contamination Resistant Low Conductivity Three Electrode Total Chlorine Sensor For Drinking Water Or Swimming Pool
|
|
Contamination Resistant Low Conductivity Three Electrode Total Chlorine Sensor For Drinking Water Or Swimming Pool
The three-electrode membrane total chlorine sensor is a type of sensor commonly used for water quality monitoring. It adopts a three-electrode design and the membrane method measurement principle. It consists of a working electrode, a reference electrode and a comparison electrode. The working electrode is responsible for detecting chloride ions in water samples, the reference electrode provides a stable potential as a reference, and the contrast electrode is used to calibrate and compensate for the effects of changes in temperature, pressure, etc. in the environment on the measurement results.
The working principle of the sensor is based on the reaction of chloride ions in water. The working electrode is covered with a selective chloride ion sensing membrane. When chloride ions come into contact with this membrane, it will cause a charge change. The concentration of chloride ions is determined by measuring the current between the electrodes, thereby indirectly determining the concentration of chloride ions in the water sample. Total chlorine content.
The three-electrode membrane total chlorine sensor sensor has the advantages of fast response, high sensitivity, and good reliability, ensuring that water quality meets safety standards.
DCP4.0MA Total chlorine sensor Three-electrode system, used for drinking water, swimming pool water, service water, process water, sea water and salt water, direct drinking water (conductivity not less than 10μs/cm), medical sewage, pH 4~12, greatly reducing dependence on pH value. Resistant to pollution, low conductivity, almost no maintenance required, optional range 0~2/5/10/20/50ppm
Areas of application: Swimming pool water, drinking water, sea water, brine (15% NaCl) Surfactants (tensides) are partially tolerated. Scope of supply: CP4 sensor, membrane cap, electrolyte Specifications
Spare parts
CP4.0 (digital output, digital internal signal processing) - The power supply is galvanically isolated inside of the sensor. - The output signal is galvanically isolated too, that means potential-free.
(Subject to technical changes!)
CP4.0 4-20 mA (analog output, analog internal signal processing) A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical isolation. Electrical connection: 2 pole terminal clamp
(Subject to technical changes!)
Electrical connection: 5 pole M12 plug-on flange
(Subject to technical changes!) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Product Tags: Swimming Pool Total Chlorine Sensor Contamination Resistant Total Chlorine Sensor Low Conductivity Total Chlorine Sensor | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Film Coating Three Electrode Total Chlorine Sensor For Seawater And Ballast Water |
|
Contamination Resistant Three Electrode Total Chlorine Sensor For Direct Drinking Water Conductivity 10μS/Cm |
|
Contamination Resistant Low Conductivity Three Probe For Sea Water Brine And Medical Wastewater |
|
Contamination Resistant Low Conductivity Three Electrode Total Chlorine Probe For Service Water Or Process Water |
|
Contamination Resistant Low Conductivity Three Electrode Total Chlorine Sensor For Drinking Water Or Swimming Pool |
|
4 - 20MA Residual Chlorine Sensor CS4 |