IP66 RS485 Laser Turbidity Transmitter For Wastewater Automatic Control

Brand Name Daruifuno
Model Number DUC2-LTU-H-D
Certification CE, ISO
Place of Origin China
Minimum Order Quantity 1
Payment Terms T/T, Western Union, MoneyGram
Supply Ability 10000 Sets per Month
Delivery Time 5-25 days
Packaging Details Carton
Product Name Turbidity Controller
Display Range 0.001NTU~4000NTU
Relay Control 2 settable SPST relays
Analog Current Output 2 settable 0/4~20mA
Communication Method Two-wire RS485 interface
OTA Without
Configuration Information Power off protection
Time/Data Record Record 14000 historical data
Protection Level IP66
Shell Material Enhanced ABS
Detailed Product Description

 

IP66 RS485 Laser Turbidity Transmitter For Wastewater Automatic Control

 
Turbidity varies widely and is typically measured from 0 to 5,000 ntu. Typical bottled drinking water is measured in single digits in ntu. Turbid water usually contains more than 1,000 ntu.

 

While turbidity itself is usually not regulated, it is indicative of the overall cleanliness of the water and may indicate the presence of suspended contaminants. This field-friendly measurement indicates the presence of multiple contaminants that stain the sample. Turbidity measurements from different locations in the treatment stream can help track improved water quality as the water moves throughout the treatment process.
 
Specification:

ModelDUC2-LTU-H-D
Software VersionDRFN TU Analysis software V1.0
Sensor InputCompatible with all DRFN's TU Digital Sensors
Display Range0.001NTU~4000NTU
Resolution0.001 NTU
Relay Control2 settable SPST relays with a maximum load of 3A/250VAC
Analog Current Output2 settable 0/4~20mA current outputs with a maximum load 1000Ω
Communication MethodTwo-wire RS485 interface; MODBUS RTU; support JSON text data format
OTA——
Display Screen

128*64 black-and-white graphic lattice LCD
adjustable backlight mode
adjustable display rate

Configuration InformationPower off protection, parameters are retained indefinitely
Time/Data Record

Year/month/day/hour/min/second, record 14000 historical data
record interval can be set between 1~999 minutes

Maintenance RecordsLast 100 times
Protection LevelIP66
Operating Environment0~60℃,RH<95% ( no condensation)
Storage Environment-20~70℃,RH<55% ( no condensation, precision instruments)
Shell MaterialEnhanced ABS
Dimension144*144*120 mm
Mounting MethodWall mounting, pipe clamping, panel installation (hole size 138*138 mm)
Electrical InterfaceThe back end reserved 3 M12*1.5 Gram head, line diameter 3~6.5 mm
Power supply

18~36VDC

Power ConsumptionAbout 12W
Cleaning SystemMax.24W
WeightAbout 800g

 

Please click the user manual of RS485 turbidity controller here:

DUC2 -LTU turbidity controller user manual.pdf

 

Brief introduction:

● Compatible with all DRFN digital laser turbidity sensors;
● Separately have a list of controller and sensor settings for quick and detailed parameter setting;
● The working status of the sensor can be queried, including reading the serial number;
● Support a variety of installation methods;
● Time and historical data recording function;
● 3.2-inch large LCD screen;
● User-friendly Chinese and English language interface;
● Password can be set to prevent misoperation;
● 2 SPST multi-function and settable relays;
● Two 0/4~20mA active current loop outputs;
● RS485 interface, Modbus RTU communication protocol;
● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;


Aplication:

◇ Pure water
◇ Ultra-pure water
◇ Waterworks
◇ Secondary water supply project
◇ Swimming pool water testing


FAQ

 

Q1. Does the conductivity controller operation interface support customization?
Yes, our conductivity controller operation interface can be tailored to customers' needs.

 

Q2. Can customer's logo be added to the controller system and cover?
Of course, we aid OEM offerings for customers. Both the boot interface and the controller shell may be delivered to the customer's logo, however there may be a minimal order amount requirement.

 

Q3. How long is the warranty period?

The company guarantees the instrument for one year (12 months) from the date of shippment, and the consumables and wearing parts in the equipment are not covered by the warranty.

 

Q4. Does the lazer turbidity controller have an ambient temperature alarm function?
Our turbidity controller has ambient temperature alarm function.

Product Tags: IP66 Protection Turbidity Controller   Laser Turbidity Transmitter   Automatic Control Turbidity Transmitter  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Suzhou Delfino Environmental Technology Co., Ltd.
Subject:
Message:
Characters Remaining: (80/3000)