RS485 Interface OTA Conductivity / TDS Analyzer For Pure Water

Brand Name Daruifuno
Model Number DUC2-EC-S-A
Certification CE, ISO
Place of Origin China
Minimum Order Quantity 1
Payment Terms T/T, Western Union, MoneyGram
Supply Ability 10000 Sets per Month
Delivery Time 5-25 days
Packaging Details Carton
Product Name Conductivity Controller
Conductivity Display Range 0.000µS /cm ~500mS/cm
Resistivity Display Range 0.01Ω.cm~18MΩ.cm
TDS Display Range 0.000mg/L~500g/L
Salinity Display Range (0.00~10.0)%
Temp Display Range -10~500℃ /14~932℉
Relay Control 2 settable SPST relays
Analog output 2 settable 0/4~20mA
Communication Two-wire RS485 interface;
OTA Default WIFI
Detailed Product Description

 

RS485 Interface OTA Conductivity /TDS analyzer For Pure Water

 

DRFN conductivity controller can complete conductivity value and conductivity value measurement, temperature measurement, temperature compensation, current output, digital communication and other functions.


The built-in clock chip can display the current time.


The built-in memory chip of the instrument can save the past historical data, which is convenient for users to find.


The instrument is equipped with a flushing relay function, and the electrode can be cleaned regularly by installing a solenoid valve.

 

Specification:

ModelDUC2-EC-S-A
Software VersionDRFN EC Analysis software V1.0
Sensor InputCompatible with all DRFN's EC Digital Sensors
Display RangeConductivity0.000µS /cm ~500mS/cm
Resistivity0.01Ω.cm~18MΩ.cm
TDS0.000mg/L~500g/L
Salinity(0.00~10.0)%
Temp-10~500℃ /14~932℉
ResolutionConductivity0.001µS /cm
Resistivity0.01Ω.cm
TDS0.001mg/L
Salinity0.01%
Temp0.1℃/ 0.1℉
Relay Control2 settable SPST relays with a maximum load of 3A/250VAC
Analog Current Output2 settable 0/4~20mA current outputs, max. load 1000Ω
Communication Method

Two-wire RS485 interface

MODBUS RTU

support JSON text data format

OTA

Default WIFI

Display Screen128*64 LCD, adjustable backlight mode, adjustable display rate
Configuration InformationPower off protection, parameters are retained indefinitely
Time /Data Record

Year/month/day/hour/min/second, record 14000 historical data

record interval can be set between 1~999 minutes

Maintenance RecordsLast 100 times
Operating Environment0~60℃,RH<95% ( no condensation)
Storage Environment-20~70℃,RH<55% ( no condensation, precision instruments)
Shell MaterialEnhanced ABS
Protection GradeIP66
Dimension144*144*120 mm
Mounting MethodWall mounting, pipe clamping, panel installation (hole size 138*138 mm)
Electrical InterfaceThe back end reserved 3 M12*1.5 Gram head, line diameter 3~6.5 mm
Power Supply

100~240VAC

Power ConsumptionAbout 7W
WeightAbout 800g

Please click the catalog of RS485 EC controller here:

Daruifuno Catalog.pdf

 

Brief introduction:
● Compatible with all DRFN conductivity sensors;
● Separately have a list of controller and sensor settings for quick and detailed parameter setting;
● The working status of the sensor can be queried, including reading the serial number;
● Support a variety of installation methods;
● Time and historical data recording function;
● 3.2-inch large LCD screen;
● User-friendly Chinese and English language interface;
● Password can be set to prevent misoperation;
● 2 SPST multi-function and settable relays;
● Two 0/4~20mA active current loop outputs;
● RS485 interface, Modbus RTU communication protocol;
● IP66 waterproof level, sealed enclosure can isolate pollution and corrosive gas;

OTA download technology as a smart configuration option for the instrument.

 

 

 Aplication:
◇ Drinking water
◇ Pure water
◇ Cooling water
◇ Sewage
◇ Industrial process water


FAQ

 

Q1. Does the conductivity controller operation interface support customization?
Yes, our conductivity controller
 operation interface can be tailored to customers' needs.

 

Q2.Can customer's logo be added to the controller system and cover?
Of course, we support OEM services for customers. Both the boot interface and the controller shell can be added to the customer's logo, but there is a minimum order quantity requirement.

 

Q3.How long is the warranty period?
The company guarantees the instrument for one year (12 months) from the date of shippment, and the consumables and wearing parts in the equipment are not covered by the warranty.

 

Q4. Does the conductivity controller have an ambient temperature alarm function?
Our EC controller has ambient temperature alarm function. 

 

Q5: What is your shipping method?
A: Small orders are delivered by international express, Bulk orders are recommended to ship by sea.


Q6: The conductivity controller with OTA function?

Yes. Our DUC2-EC-S-D conductivity controller Default with OTA

Product Tags: RS485 Interface TDS Analyzer   Pure Water TDS Analyzer   OTA Conductivity Analyzers  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Suzhou Delfino Environmental Technology Co., Ltd.
Subject:
Message:
Characters Remaining: (80/3000)