China pH ORP Analyzer manufacturer
Suzhou Delfino Environmental Technology Co., Ltd.
Create value for customers!
6
Home > Products > pH ORP Analyzer >

Differential Sign Industry Online PH Transmitter For Water Quality Testing

Browse Categories

Suzhou Delfino Environmental Technology Co., Ltd.

City: suzhou

Province/State:jiangsu

Country/Region:china

Tel:86-15716217387

Contact Person:
Ms.Yuki Fu
View Contact Details

Differential Sign Industry Online PH Transmitter For Water Quality Testing

Brand Name Daruifuno
Model Number APX2-G4 A/D
Certification CE, ISO
Place of Origin China
Minimum Order Quantity 1
Payment Terms T/T, Western Union, MoneyGram
Supply Ability 10000 Sets per Month
Delivery Time 5-15 days
Packaging Details Carton
Product Name PH Meter
Measurement range -2~16pH ±2000mV -10~150℃
Ground Differential signal
Temperature Compensati Automatic or manual(NTC10K or PT1000
Relay output Two SPST relays
Communication RS485 modbus RTU
Analog output Two 0/4~20mA
Sensor Diagnosis Image display with buzzer warning
Time/Data recordin Record 14,000 historical data
Detailed Product Description

 

Differential Sign Industry Online PH Transmitter For water Quality Testing

 

PH/ORP gauges has a temperature detection and temperature compensation function, supporting pH electrodes with temperature to measure temperature changes in aqueous solutions. It is a patented temperature drift compensation technology, which makes the instrument more stable and accurate in all kinds of environments.

 

The PH/ORP gauges use salt-bridged primary battery electrodes (PH electrodes) to detect changes in the concentration of hydrogen ions in the solution, which affect the electrode level. It is usually made of glass and commonly known as PH glass electrode measurement. Mathematic defines pH as a commonly used congenital negative value for the concentration of hydrogen ions, i.e. pH=-lg[H⁺]

 

Specification:

Product NamePH ORP meter
Product ModelAPX2-G4 A/D
Software VersionDRFN PH Analysis software V1.0
pH Range-2~16pH
ORP Range± 2000mV
GroundDifferential signal (Compatible with ground sensor)
Temperature Range-10~150℃ /14~302℉
Resolution0.01pH / 1mV/ 0.1℃
AccuracyPH:±0.02 pH /ORP:±2 mV
Temperature CompensationAutomatic or manual(NTC10K or PT1000)
Relay Control2 settable SPST relays, maximum load 3A / 250VAC
CommunicationRS485 Modbus RTU
Signal OutputTwo 0/4~20mA current outputs maximum load 1000Ω
Sensor DiagnosisImage display
ConfigurationPower failure protection, indefinite retention of parameters
Time/Data recordingRecord 14,000 historical data; Save the last 100 maintenance data
LanguageChinese and English
Protection GradeIP66
Enclosure MaterialEnhanced ABS
Power SupplyAC: 100~240V or DC:18~36V
Dimension144*144*120mm
Hole Size138*138mm
Operating Temperature0~60℃, RH<95%, non-condensing
Storage Temperature-20~70℃, RH<55%, non-condensing
Installation Methodwall mounting, pipe clamp, panel
Weight900g
Power ConsumptionAbout 7W

Please click Catalog here:

Daruifuno Catalog.pdf

 

Brief introduction:

  • PH glass electrode measurement method, applied to various PH/ORP monitoring and dosing control occasions;
  • Configuration, and fault analysis of the instrument.
  • Differential signal PH/ORP online controller, stable measurement and strong anti-interference ability;
  • Support a variety of installation methods, wall mounting, pipe clamp installation, panel installation;
  • Clock and historical data recording function to meet higher data management requirements;
  • 128*64 large LCD screen,multiple languages available;
  • Record 14,000 historical data, and the recording interval can be set between 1 and 999 minutes;
  • The protection grade of the enclosure is IP66;
  • Two settable SPST multifunctional relays;
  • Two high-precision 0/4~20mA current outputs;
  • A two-wire RS485 interface, the communication protocol is MODBUS RTU;
  • 128*64 large LCD screen, multiple languages available;
  • The menu password can be set to facilitate hierarchical management;
  • The meter can not only perform temperature compensation on the test sample, but also self-check the operating temperature of the instrument, compensate for the hardware temperature changes caused by temperature drift, and make the test results more accurate;
  • Provide AC and DC power supply modes, both of which are wide-voltage power supply.


Aplication:
Water treatment monitoring

Drinking water,surface water,water quality analyze,ground water,ect.
 
Industrial process monitoring and dosing control
Chemical,petroleum,paper,food and medicine,PCB manufacturing,etc.

FAQ
Q1. Does the instrument have a self-diagnostic function and how does it prompt?

A: The pH meter has self-diagnosis function.When the instrument is in calibration and maintenance,it can diagnose the PH/ORP sensor,if there is improper operation or poor PH/ORP sensor characteristics, the screen makes an image display and advises the user to re-maintain or replace the sensor.


Q2. What are the special advantages of the pH instruments?
A: The instrument can not only compensate the temperature of the test sample by connecting the temperature sensor, but also self-check the working temperature of the instrument in real time. When the working temperature of the instrument changes, the instrument compensates the hardware change caused by the temperature drift. Make the test results more accurate, this is a patented technology.

Product Tags: Online PH ORP Transmitter   IP66 PH ORP Controller   Online switch control PH ORP transmitter  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Suzhou Delfino Environmental Technology Co., Ltd.
Subject:
Message:
Characters Remaining: (80/3000)