24V Two SPST Disinfectant Chlorine Meter For The Measurement Of
Chlorine Brief Introduction Residual chlorine means that after chlorine is put into the water,
in addition to the bacteria, microorganisms, organics, inorganics,
etc. in the water, a part of the chlorine is consumed, and a part
of the chlorine is left. This part of the chlorine is called
residual chlorine. Residual chlorine can be divided into chemical
residual chlorine and free residual chlorine. Total residual
chlorine is the sum of chemical residual chlorine and free residual
chlorine. DUC series disinfectant chlorine meter is a digital universal
controller for measuring the concentration
of chlorine. Each controller will be pre-installed with a
set of embedded software to adapt to different disinfectant
sensors. Users can use the operation panel in front of the DUC controller to
calibrate the sensor, set the output parameters, and routine
maintenance, which is convenient and quick. The enclosure protection grade of this meter is IP66. This
material can effectively isolate the pollution and corrosive gas
from the external environment. - The instrument has 2 SPST multifunctional relays that can be set
and 2 high-precision 0/4~20mA current outputs.
Advantages Of The Chlorine Meter - The DUC disinfectant chlorine analyzer has the functions of clock and historical data recording, which
can meet the higher management requirements of users for data.
The CL meter has a 3.2-inch display screen and uses a 128*64
black and white graphic dot matrix LCD liquid crystal display, with
reasonable interface settings and simple operation. The shell material of the instrument is reinforced ABS, the shell
is strong, corrosion-resistant and wear-resistant. The overall size
of the DUC free chlorine meter is 144*144*120mm, and the user can choose a variety of installation
methods such as wall-mounted installation, pipe clamping
installation, and panel installation. - The controller has a power-off protection configuration, and
the parameters can be kept indefinitely.
Applications Of The Chlorine Meter It is applied to online monitoring of chlorine concentration in
drinking water and industrial process water disinfection and
sterilization process, sewage treatment and circulating cooling
water treatment, and can also be used in swimming pools and other
places where chlorine concentration needs to be measured. Technical Parameters Product Name | Disinfectant Chlorine Meter | Product Model | DUC2-CL-H-D | Software Version | DRFN chlorine Analysis software V1.0 | Display Range | 0.01mg/L~100g/L | Resolution | 0.01mg/L | Relay Control | 2 settable SPST relays max. load 3A/250VAC | Analog Current Output | 2 settable 0/4~20mA active current loop output max. load 1000Ω | Communication Method | Two-wire RS485 interface; MODBUS RTU; support JSON text data format | Display Screen | 128*64 LCD, adjustable backlight mode | Time History/Data Record | Year/month/day/hour/min/second, record 14000 historical data | Protection Level | IP66 | Operating Environment | 0~60℃, relative humidity less than 95% (no condensation) | Storage Environment | -20~70℃, relative humidity less than 55% (no condensation) | Shell Material | Enhanced ABS | Size | 144*144*120mm (hole size 138*138 mm) | Mounting Method | Wall mounting, pipe clamping, panel mounting | Power Supply | 18-36V DC | Weight | 800g | Power Consumption | 7W |
The Matching DRFN Chlorine Sensors Recommendation Type: | Measuring range: ppm | Resolution: ppm | Output signal: | Power supply: | Item number: | CL4.2H-M0c | 0.005~2.000 | 0.001 | Modbus RTU | 9~30 V DC 20~56 mA | 3326225 | CL4.2N-M0c | 0.05~20.00 | 0.01 | 3326226 | CL4.2L-M0c | 0.5~200.0 | 0.1 | 3326227 |
Type: | Measuring range: ppm | Resolution: ppm | Output signal: | Power supply: | Item number: | CC1H-M0c | 0.005~2.000 | 0.001 | Modbus RTU | 9~30 V DC 20~56 mA | 3426610 | CC1N-M0c | 0.05~ 20.00 | 0.01 | 3426611 |
- Model: CS4
pH range: 4~9 - Pressure range: 0~3 bar, no pressure surges or fluctuations
- Temperature range: 0~ 45℃ (no ice crystals in measurement water)
- Integrated automatic temperature compensation
- Response time: T90 about 2min
- Flow rate: about 30 l/h, low flow-dependence
Shaft length: standard 175 mm - Connection: Modbus RTU with M12 male
- Material: PVC-U, PEEK, stainless steel 1.4571, microporous
hydrophilic membrane
Applications: Fresh water and sea water at 10 µS/cm~50 mS/cm,
surfactants are partially tolerated
Type: | Measuring range: ppm | Resolution: ppm | Output signal: | Power supply: | Item number: | CS4H-M0c | 0.005~2.000 | 0.001 | ModBus RTU | 9~30 V DC 20~56 mA | 3426360 | CS4N-M0c | 0.05~20.00 | 0.01 | 3426361 | CS4L-M0c | 0.5~200.0 | 0.1 | 3426362 |
- Model: CP3
pH range: 4~12 - Pressure range: 0~0.5 bar, no pressure surges or fluctuations
- Temperature range: 0~ 45℃ (no ice crystals in measurement water)
- Integrated automatic temperature compensation
- Response time: T90 about 2min
- Flow rate: about 30 l/h, low flow-dependence
Shaft length: standard 175 mm - Connection: Modbus RTU with M12 male
- Material: PVC-U, PEEK, stainless steel 1.4571, microporous
hydrophilic membrane
Applications: Swimming pool, drinking and seawater, surfactants are
partially tolerated; special electrolyte for the use in sea water
Type: | Measuring range: ppm | Resolution: ppm | Output signal: | Power supply: | Item number: | CP3H-M0c | 0.005~2.000 | 0.001 | Modbus RTU | 9~30 V DC 20~56 mA | 3326960 | CP3N-M0c | 0.05~20.00 | 0.01 | 3326961 |
Type: | Measuring range: ppm | Resolution: ppm | Output signal: | Power supply: | Item number: | CN1.1H-M0c | 0.005~2.000 | 0.001 | Modbus RTU | 9~30 VDC 20~56 mA | 3326610 | CN1.1H-M0c | 3326612 |
- Model: AS2 AS3
pH range: 5~9 - Pressure range: 0~8 bar, no pressure surges or fluctuations
- Temperature range: 0~50℃(AS2), 0~70℃ (AS3)
- Integrated automatic temperature compensation
- Response time: T90 about 30s
- Flow rate: about 30 l/h
Shaft length: standard 175 mm - Connection: Modbus RTU with M12 male
- Material: PVC-U (AS2), PEEK (AS3)
Applications: Fresh water, especially drinking water, up to max.
70℃
Type: (up to 50℃) | Measuring range: ppm | Resolution: ppm | Output signal: | Power supply: | Item number: | AS2H-CL-M0c | 0.005~2.00 | 0.001 | Modbus RTU | 9~30 V DC 20~56 mA | 3426770 | AS2N-CL-M0c | 0.03~10.00 | 0.01 | 3426771 |
Type: (up to 70℃) | Measuring range: ppm | Resolution: ppm | Output signal: | Power supply: | Item number: | AS3H-CL-M0c | 0.005~2.00 | 0.001 | Modbus RTU | 9~30 V DC 20~56 mA | 3426720 | AS3N-CL-M0c | 0.03~10.00 | 0.01 | 3426721 |
|