200KVA 3 Phases Low Frequency Online UPS Uninterruptible Power
Supply
200KVA Modular UPS Low Frequency UPS On-Line 3 Phases
Uninterruptible Power Supply Ups
Maximum reliability and availability
Connect up to 6 units in parallel or N+1 redundancy, even of
different power ratings.The UPS continue to work in parallel even
if one of the interconnecting communication cables is disconnected
(CLOOSED LOOP).
Low consumption level:
ZGD330 can achieve efficiencies >98% thanks to selectable
Economy Mode which can be used in stable electrical environments to
provide power supply continuity when the mains fail.
Advance communication
Compatible with TeleNetGuard for remote maintenance; Advanced,
multi-platform communication for all operation systems and network
environments: Watch & Save 3000 monitoring and shut-down
software included, with SNMP agent, for Windows 2008, Vista,2003,
XP; Mac OS X, Linux, Novell and most popular Unix operating
systems;
The UPS is supplied with a cable for direct connection to the
PC(Plug and Play); RS232 double Serial port; Installation slot for
an Emergency Power Off (EPO) interface to allow the UPS to be
switched off remotely in an emergency; Generator interface: enables
resynchronization of the UPS output from a generator supply which
may be subject to phase and frequency variations. The interface
also enables more economic use of the battery charge.
Expandability:
The units can be connected in parallel up to 8 units to increase
power availability or redundancy. The single module or the system
can be expanded any time to suit power requirements without
influencing the initial investment.
Model power | ZGD330 10-200KVA |
10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 160KVA | 200KVA |
Capacity | 8KW | 12 KW | 16 KW | 24 KW | 32 KW | 48 KW | 64 KW | 80 KW | 96KW | 128 KW | 160 KW |
Input |
Rated voltage | 380/400/415 Vac three-phase |
Voltage range | ±20% |
Frequency range | 45-65Hz |
Power factor | >0.92with harmonic filter |
Current harmonic distortion | <5%with harmonic filter |
Soft Start | 0-100% in10" |
Bypass Input |
Rated voltage | 380/400/415 Vac three-phase |
Permitted voltage range | ±15%(selectable from ±10% to ±25% from front panel) |
Rated frequency | 50/60Hz |
Permitted frequency range | ±2%(selectable from ±1% to ±5% from front panel) |
Standard features | Back Feed protection; split bypass line |
Batteries |
Type | Maintenance-free lead-acid VRLA AGM / GEL;NICd |
Battery voltage | 384VDC | 480VDC |
Maximum recharge current(A) | 0.2×C10 |
AC ripple voltage | <1% |
Inverter Output |
Number of phases | 3+N |
Rated voltage(V) | 380Vac |
Regulation of the output voltage | 380~424Vac phase/neutral(from control panel) |
Crest factor (Ipeak / Irms) | 3:1 |
Static stability | ±1% |
Dynamic stability | ±5% |
Frequency | 50/60Hz configurable |
Overload | 110% 125% 150% of the rated current for 5h/10'/1' |
Frequency stability | ±0.05% on mains failure;±2%(selectable from ±1% to ±5%)with mains
supply present |
Remote signaling | Volt free contacts |
Remote controls | EPO and Bypass |
Communication | RS232 + romote contacts |
Operation temperature | 0ºC/ + 40ºC |
Relative humidity | <95% non condensing |
Noise | 54dBA at 1m | 50-65dBA at 1m |
Protection degree | IP20 |
Efficiency smart mode | up to 98% |
Compliance | Safety:EN 62040-1-1(Directive 2006/95/EC); EMC:6200-2(Directive
2004/108/EC) |