Description Module Ultrasonic Flowmeter flow meter Module Ultrasonic Flowmeter flow meter utilizes two transducers
that function as both ultrasonic transmitters and receivers. The
Ultrasonic liquid flow meter are clamped on the outside of a closed
pipe at a specific distance from each other. This flowmeter can be
virtually applied to a wide range of measurement. A variety of
liquid applications can be accommodated: ultra-pure liquids,
potable water, chemicals, raw sewage, reclaimed water, cooling
water, river water, plant effluent. etc Detailed Images Module Ultrasonic Flowmeter flow meter
Specification Module Ultrasonic Flowmeter flow meter Items Performance & Parameter | Convertor | Principle | Transit- time ultrasonic flowmeter | Accuracy | ±1% | Operation | 4 keyboards operation | Signal Output | 1 way 4~ 20mA output, electric resistance 0~ 1K,accuracy0. 1% | 1 way OCT pulse output( Pulse width 6~ 1000ms,default is 200ms) | 1 way Relay output | Signal Input | 3 way 4~ 20mA input, accuracy 0. 1%,acquisition signal such as
temperature, press and liquid level | Connect the temperature transducer Pt100, can finish the
heat/energy measurement | Data Interface | Insulate Rs485 serial interface, upgrade the flowmeter software by
computer, support the MODBUS | Special Cable | Twisted-pair cable, generally, the length under 50 meters; Select
the RS485, transmission distance can over 1000m | Pipe Installation Condition | Pipe Material | Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC,
Aluminum, Glass steel product, liner is allowed | Pipe Diameter | 15~ 6000mm | Straight Pipe | Transducer installation should be satisfied: upstream10D,
downstream 5D, 30D from the pump | Measuring Medium | Type of Liquid | Single liquid can transmit sound wave, such as Water (hot water, chilled water, city water, sea water,
waste water, etc.); Sewage with small particle content; Oil ( crude oil, lubricating
oil, diesel oil, fuel oil, etc.); Chemicals ( alcohol, etc.); Plant
effluent; Beverage; Ultra- pure liquids, etc. | Temperature | - 30~ 160℃ | Turbidity | No more than 10000ppm and less bubble | Flowrate | 0~±7m/ s | Working Environment | Temperature | Convertor:- 20~ 60℃;Flow Transducer:- 30~ 160℃ | Humidity | Convertor: 85% RH;Flow Transducer:can measure under water, water
depth≤2m(tansducer sealed glue) | Power Supply | DC8~36V or AC10~30V | Power consumrtion | 1. 5W | Dimension | 95*95*35MM(Convertor) |
Features Module Ultrasonic Flowmeter flow meter * Large-screen LCD * Built-in data-logger * High accuracy measuring * Small and light * Non-contacting measuring * Built-in rechargeable battery * Wide measuring range * RS-232/RS485 serial interface
|