Stationary Wall Mounted Zetron Mic300 C2h4 Ethylene Gas Leak Detector
|
MIC300 Bromomethane CH3Br Gas Monitoring Equipments PID Detection Principles OVERVIEW
MIC300 Series gas detector can be used in 24 hours continuous
online monitoring of concentrations of multiple types of gases in
the filed.The types for detection are more than 500 types. FEATURES ●Fast and efficient gas detection function ① It can be used in 24 hours continuous online monitoring of single field gas concentration and the types for detection are more than 500 types.
●Diversified communication methods ① It is possible for the real-time monitoring via the wired or remote wireless transmission, and network transmission. ② Three-wire system 4 ~ 20mA standard signal and standard bus RS485 (modbus-RTU) simultaneous output. ③ It is compatible with secondary instrument, data acquisition module, PLC, DCS system, and it is possible to drive the related equipment.
●Powerful and convenient humanized function ① Data recovery function; in case of mis-operation, it is possible to select partial or full recovery. ② Multiple alarm modes, and multi-directional and threedimensional indication alarm states, includes: 2 sets of relay switch output, sound & light alarm (optional configuration).Alarm types include: concentration alarm, and failure alarm. ③ Mis-operation recognition function: automatic recognition and prevention of the concentration calibration mis-operation, which is possible to avoid the poor performance that may becaused by human factors. ④ Zero-point automatic tracking; long-term use will not be affected by the zero drift. ⑤ Multi-level calibration for target points, can ensure the linearity and accuracy of the measurements. ⑥ Broad operating temperatures: -40~+70℃, and temperature compensation is supported. ⑦ Intrinsically safe circuit design, explosion-proof, with Level II lightning protection, and anti-static capabilities. Meet the national standard, and it is resistant to the high-intensity pulse surge current. With the function of preventing the reverse connection. It is compliant with EMI, and EMC standards. Application
Fixed gas detector is mainly used in underground tunnels, sewage treatment plants, chemical plants, steel plants, coal mines, boiler rooms, oil pipelines, gas stations, indoor air quality testing, sterilization, frozen warehouses, underground corridors and other mixed gas scenarios. SPECIFICATION
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: stationary mic300 wall mounted mic300 mic 300 gas leak detector |
Zetron VOXI Fixed Photo Ionization Detectors To Monitor Volatile Organic Compounds VOCs |
Oled Display Rs485 Pid Photoionization Detector Zetron Voxi Series |
Voc Zetron VOXI PID Fixed Photo Ion Detector And Alarm Systems In Petrochemical Plants |
CE Zetron MIC500S Outdoor Gas Leak Detector Electrochemical / IR Sensor |
MIC500S Zetron Pump Suction Nitrogen Dioxide Detector For Explosive |
Fixed Zetron MIC500S Combustible Gas Leak Detector Pipeline Type And Wall Mounting Type |