CE Peripheral Vision Test Equipment Glaucoma Examination

Brand Name SYSEYE
Model Number BIO-1000
Certification CE
Place of Origin China
Minimum Order Quantity 1
Price $2,800.00-$3,200.00
Payment Terms T/T
Supply Ability `100
Delivery Time 5 working days
Packaging Details 412mm ( length) * 497mm ( width) * 513mm ( height )
Product name Visual Field Analyzer
Size 412mm ( length) * 497mm ( width) * 513mm ( height )
Weight 17kg
Power 100- -240V,50-60Hz
Feature The Accuracy Of Visual Field Diagnosis Is Improved
Environment light detection Automatic
Inspection range 90°
Inspection distance 30cm
Detailed Product Description

The Accuracy Of Visual Field Diagnosis Is Improved Visual Field Analyzer

 

The purpose of visual field examination for glaucoma is twofold: to detect the presence of optic nerve damage and to monitor the progression of the disease. Visual field defect was detected to determine the presence of optic nerve damage. The diagnosis of glaucoma is not completely determined by intraocular pressure. High intraocular pressure alone without optic disc damage and corresponding visual field defect can only be diagnosed as hyperocular pressure. In contrast, in normal intraocular glaucoma, the intraocular pressure is normal, with only optic disc changes and visual field defects. Therefore, visual field defect is one of the main indicators for the diagnosis of glaucoma, so the Visual Field Analyzer  is the doctor's best help, which is especially important in primary open Angle glaucoma. Clinically, patients with ocular hypertension should not be treated. Regular follow-up of fundus and visual field should be conducted. Once early optic disc damage and visual field changes occur, treatment should be given.

 

Specifications:

 

Basic specification

small size Visual Field Analyzer

Inspection range

90°

Inspection distance

30cm

Background light brightness

White 31.5asb

Visual target brightness

1asb--- -10000asb

Visual target size

GoldmannIII

Visual target interval time

200ms

Visual target interval time

Standard or adjustment according to patient reflection

Threshold test model

Center5-°16, center10° -68, 24 -2, 30-2, 30° -60° nasal step

Upper Threshold test model

30°- 40, 30°-76, P-60, 60°-81, 60°-120,190°-135 nasal side

Special detection strategy

Esterman monocular, Esterman binocular . user- customized test, 150P driver monocular fast detection, 150P driver monocular standard detection , upper 36 detection, blind spot detection,150horizontal straightness detection

Pupil size test

Automatic

Fixation monitoring

Blind spot monitoring , eye position eye position deviation alarm, eye deviation curve

Environment light detection

Automatic

Analysis software

Reliability analysis , single vision report, triple vision report, GPA half vision analysis, GPA glaucoma developing analysis , VFI vision index analysis

Operation system

Win7 above

 

Feature 

Visual Field Analyzer

1. Comprehensive real-time monitoring, heiji-krakau physiological blind spot monitoring. Gaze tracking/head position tracking, automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection.

2. Personalized design, accurate clinical analysis, accurate and rapid examination strategy.

3. Under international Goldman standard, providing a variety of calssic test procedures and report analysis.

 

 

 

Features of Visual Field Analyzer

 

1. Comprehensive real-time monitoring, heiji-krakau physiological blind spot monitoring. Gaze tracking/head position tracking, automatic measurement of pupil diameter, reduce the impact of pupil effect on visual field detection.

2. Personalized design, accurate clinical analysis, accurate and rapid examination strategy.

3. Under international Goldman standard, providing a variety of calssic test procedures and report analysis.

4. Provide a comprehensive software testing program.


 

 

Company Introduction

Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.

Product Tags: CE Peripheral Vision Test Equipment   CE GPA Peripheral Vision Test Equipment   CE White 31.5asb Perimeter Ophthalmic Instrument  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Chongqing Bio Newvision Medical Equipment Ltd.
Subject:
Message:
Characters Remaining: (80/3000)