ISO RS485 communication Smart Motor Protector / Motor Protection Device
|
|
General ARD series intelligent motor protector (hereinafter referred to as protector) can perform various conditions such as start timeout, overload, phase failure, unbalance, underload, ground/leakage, blockage, short circuit and external fault during motor operation. Protection, and SOE fault event recording function, convenient for on-site maintenance personnel to find the cause of the fault. Suitable for coal, petrochemical, smelting, electric power, ships, and civil construction. The protector has RS485 remote communication interface, DC 4 ~ 20mA analog output, and PLC, PC and other control machines form a network system. Remote monitoring of motor operation.
Features ● Measurement functions are divided into basic measurement (current parameter) and co-selection measurement (voltage, power, phase sequence, residual current (leakage current); ● Start timeout, overload, stall, block, underload, phase failure, unbalance, residual current (ground/leakage), temperature, external fault, phase sequence, overvoltage, undervoltage, underpower, overpower, tE time Motor comprehensive protection function; ● 9-channels DI passive dry node input, signal power supply with built-in DC24V power supply; ● 5-channels DO output, which can meet the direct start, star-delta start, autotransformer start, soft start and other starting modes. Real-time remote control "start/stop" operation of the remote master station can be realized through the communication bus; ● It has standard RS485 communication interface and adopts Modbus-RTU and Profibus-DP communication protocol to ensure fast and reliable communication of the host computer; ● It has a DC4-20mA analog output interface and is directly connected to the DCS system to monitor the field devices.
Technical Parameters
Function
Wiring
Typical connection |
| Product Tags: RS485 Smart Motor Protector RS485 Motor Protection Device ISO Smart Motor Protector |
|
Acrel ARD Series Smart Motor Protection Relay |
|
Acrel ARD2-250 Timeout Startup Over Load Unbalance Blocking Short Circuit 55KW 75KW 90KW 110KW 132KW Motor Protector |
|
Acrel ARD2F Series Smart Motor Protection Relay Low-voltage Motor Circuits Microcontroller Technology Protect The Motor |
|
Acrel ARD2F Series Smart Motor Protection Relay Low-voltage Motor Circuits Ensuring The Safe Operation Of The Motor |
|
ISO RS485 communication Smart Motor Protector / Motor Protection Device |
|
Start Timeout Smart Motor Protector Comprehensive Protection Device |