Revolutionize Your Power Management Strategy With CNM Series
Rack-Mounted Modular UPS Product Description
Modular UPS adopts standard structural design, each system consists
of a power module, monitoring module, and static switch. The power
modules can be connected in parallel to share the load evenly among
them. In case of failure, it will automatically exit the system and
other power modules will take the load, which can be expanded both
horizontally and vertically. The unique redundant parallel
technology makes the equipment without a single point of failure to
ensure the highest availability of power supply. All modules can be
hot-plugged and replaced online, and maintenance is the safest
power protection solution. | |
Product Feature
| Multiple operating modes The product has a variety of systems to choose from, easy to
operate, and can be realized in a variety of inlet and outlet
modes: 1/1, 1/3, 3/1, or 3/3, input frequency can be set to 50Hz
and output frequency can be set to 60Hz, the output voltage can be
set to 220V, 230V, 240V, if you configure the input and output
transformers to meet the global scope of all countries and regions
of power supply needs. Small size, high power density High working efficiency and high power density are the most
important features. It can provide 5KVA (4000W), 10KVA (8000W),
15KVA (12KW) and 20KVA (16KW) power output. Expandability, easy to install, maintain, replace, and upgrade The model consists of various modules, which can realize the
function of hot plugging and dialing. The rack of each module can
be completely separated, which is convenient for users to expand or
reduce the capacity in the future, and easy to use. Online
replacement and online maintenance can be realized, which reduces
the difficulty of maintenance and the time of maintenance. The size
of each module is designed by the standard 19-inch structure, so
that the appearance of the whole machine is consistent with the
standard rack, beautifying the appearance of the machine, and the
module can be common with the standard rack. Redundancy, decentralized parallel logic control Parallel control between the modules adopts decentralized logic
control, no host and slave, any one module dial out or insert will
not affect the normal work of other modules, on-demand N +1, N + X
redundancy system, reducing the risk factor of the system itself
and the load is the load by the UPS to protect the time of the
overall increase. Not only increases the reliability of the whole
machine but also simplifies the user's maintenance difficulties. |
Product Advantages
First, "modular redundant parallel" technology to avoid waste of
resources. In the industry users of the information network power
supply system construction, often on the high-end UPS capacity to
produce the wrong, or too low or too high expectations, the results
may lead to high procurement costs, can not meet the load needs or
cause resources, space and energy waste and so on. Modular UPS
through the expandable module structure effectively solves this
problem, it can help users in future development is not clear in
the case of phased construction and investment.
Second, high security, easy to maintain the hot-swap technology
breaks through the application bottleneck. Traditional high-end UPS
during routine maintenance, equipment maintenance is required to
take the way to turn bypass, and the load in this case is not
protected by the UPS. Therefore, if power interruption, overload
and other faults occur at this time, will cause serious losses, and
its maintenance process will be relatively cumbersome, and
unfavorable time. Modular UPS systems used in the hot-swap
technology can allow a single module without the need for power
outages under the premise of arbitrary entry or exit from the
parallel unit, thus realizing the parallel system of online
maintenance, while no special instruments or techniques can be
carried out.
Third, the power phase multiple system technology reduces
procurement and management costs. Traditional high-end UPS power
input and output phases are fixed, so users often increase the
number of UPS to take into account the different phases and
capacity in the construction of the power supply system. Under the
modular UPS system, the power supply phase multiple system
technology can be used to change the constraints caused by the past
unity, the user no longer needs to consider how to purchase
different phases or capacities of the UPS products to adapt to the
needs of the system.
| |
Data Sheet
Model CNM | 020/10 | 030/15 | 040/20 | 040/10 | 045/15 | 060/15 | 080/20 | 090/15 | 120/20 | Rate Power | 20KVA/20KW | 30KVA/30KW | 40KVA/40KW | 40KVA/40KW | 45KVA/45KW | 60KVA/60KW | 80KVA/80KW | 90KVA/90KW | 120KVA/120KW | Main input | Input | 3P5W(3P+N+PE) | Rate Voltage | 380/400/415VAC(L-L);220/230/240VAC(L-N) | Rate Freq | 50/60Hz | Input PF | >0.99 | Current Distortion | THDi<3%(100%Linear load) | Voltage Range | 304-478VAC(L-L)full load;304-228VAC(L-L)power derate from 100%to
75% | Freg.Range | 40-70Hz | Battery | Rate voltage | ±240VDC(adjustable for 32-44 sections) | Charging Capacity | 20%*Pout | Charging Accuracy | ±1% | Bypass | Rate Voltage | 380/400/415VAC(L-L);220/230/240VAC(L-N) | Voltage Range | Range:-40%-+25%,Settable,default-20%~+15% | Overload | 110%,long time operation;110%<load<125%,5 mins 125%<load<150%,1min;>150%,1second | Inverter | Rate Voltage | 380/400/415VAC(L-L);220/230/240VAC(L-N) | Rate Freq | 50/60Hz | Output PF | 1 | Voltage Accuracy | ±1.0% | load Response | <5%(20%-80%-20%step load) | Recovery Time | <20ms(0%-100%-0%step load) | Output THDu | <1%(linear load),<5%(non-linear load according to IEC
62040-3) | Overload | 110%,1 hour;125%,10 mins;150%,1min;>150%,200ms | Frequency Accuracy | 0.1% | Synchronize Window | Settable,±0.5Hz-±5Hz,default±3Hz | Slew Rate | Settable,0.5Hz/S-3Hz/S,default 0.5Hz/S | Phase Accuracy | 120°±0.5° | System | Efficiency | Normal Mode≥96%;Battery Mode≥96% | Display | LED+7inch touch LCD | Certification-Safety | IEC62040-1,IEC60950-1 | Certification-EMS | IEC62040-2;IEC61000-4-2(ESD);IEC61000-4-3(RS);IEC61000-4-4(EFT);IEC61000-4-5(Surge) | IP Degree | IP20 | Configuration | USB,RS232,RS485,Dry contact,Cold start | Option | SNMP card,AS400 card,Parallel kit,LBS,Air filter,Bottom entry
kit,Wheels kit | Environment | 0-40℃(operation);-25~70(storage);0-95%(Humidity,non-condensing) | Noise(dB)(1meter) | 65dB @100%load,62dB @45%load | Dimension | Cabinet(W*D*H)mm | 482*700*396(9U, wheels not included) | 482*700*662(15U, wheels not included) | 482*700*840(19U, wheels not included) | Module(W*D*H)mm | 440*555*85(2U) |
Applications
- Data centers
-
- Telecommunications networks
-
- Industrial facilities
-
- Medical facilities
-
- Financial institutions
-
- Government agencies
-
- Educational institutions
| |