42U Integrated Rack Data Center Solutions For Edging Computing

42U Integrated Rack Data Center Solutions For Edging Computing

Brand Name Coolnet
Model Number Mirco data center
Certification CE ISO
Place of Origin China
Minimum Order Quantity 1pcs
Price USD3000-10000/pcs
Payment Terms L/C, T/T
Supply Ability 200 SETS PER MONTH
Delivery Time 20-35 days
Packaging Details Standard export package
Voltage 380v/220v,110-220v/50-60Hz,220V/50Hz
Cabinet Multiple Cabinets
Cooling DC Inverter Rack Mounted PAC Units
Power Rack PDU and UPS
Detailed Product Description

Integrated Rack Data Center Solutions For Computer Rooms In Edging Computing

 

Product Introduction                                                           

Coolnet rack data center integrates power supply, environment, weak current, lightning protection, and monitoring systems, and has a new product concept of cabinet-type computer room. It has the characteristics of rapid deployment, precise cooling, intelligence, visualization, and modularization. It has low requirements on the external environment, strong availability, high reliability and good adaptability, which can provide stable and safe guarantee for the operation of IT equipment, and will continue to update with future needs.

 

 

 

Benefits                                                                                  

   

Feature                                                                                    

 

 

Power Distribution System
 

It consists of UPS, battery, power distribution unit and PDU. The UPS is installed in a standard 19-inch rack, with high frequency double conversion, high efficiency, suitable for a wide range of voltage and frequency, and compatible with generator access. Safe and reliable lead-acid batteries are used, with long life and low risk. Power distribution unit rack-mounted design, safe and reliable quality, easy maintenance.

 

Monitoring System

 

The intelligent monitoring system has the function of centralized management, and supports the remote management and maintenance of the monitoring system. The remote operation interface is consistent with the local operation interface. The monitoring system is mainly composed of various layers of the modular data center infrastructure, such as power distribution, cooling, security and environmental systems and other components in real-time monitoring.

 

 

Advantage                                                                                

 

Wisdom

 

  • When there are multiple outlets, unified monitoring, remote access, and centralized operation and maintenance management are optional;
  • Precise energy efficiency management, clear electricity consumption;
  • All-round alarm interface, support SMS sending, timely understanding of equipment abnormalities

 

Efficient

 

  • Close the hot and cold air flow to avoid the mixed flow of air flow, thereby improving the cooling efficiency and reducing the PUE;
  • Optional high-frequency rack UPS, or modular UPS, efficient operation;
  • Near-end cooling to reduce air loss;
  • Adopt DC inverter compressor and stepless speed regulating EC fan, which can run efficiently under load

 

 

Technical Parameter                                                                  

 

ModelEC08EC12EC20ERx
Power3KVA3-6KVA6-30KVA
Number of cabinets0.8m high cabinet, available space 8U1.2m high cabinet, available space 16UStandard 42U cabinet, free space 30U2-10 standard 42U glass door cabinets
Enclosed cabinetGlass door, IP5X, full cold and hot channel sealing
Power supply220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
RefrigerationUnique air duct design, without air conditioner and outdoor unitRefrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring

 