DC Inverter Integrated Data Center For Small And Medium Server Rooms

DC Inverter Integrated Data Center For Small And Medium Server Rooms

Brand Name Coolnet
Model Number Mirco data center
Certification CE ISO
Place of Origin China
Minimum Order Quantity 1pcs
Price USD3000-10000/pcs
Payment Terms L/C, T/T
Supply Ability 200 SETS PER MONTH
Delivery Time 20-35 days
Packaging Details Standard export package
Voltage 380v/220v,110-220v/50-60Hz,220V/50Hz
Cabinet Two Cabinets
Cooling DC Inverter Rack Mounted PAC Units
Operating 380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V
Detailed Product Description

Simple And Deeply Integrated Rack Data Center For Small And Medium Server Rooms

 

Product Introduction                                                                

Coolnet Rack Data Center refers to a product in which devices with more functions are installed in the cabinet. The micro-module integrated cabinet system is for safe city police station outlets, small and medium-sized enterprises, large enterprise branch offices, telecommunications business halls, bank outlets, railway communication computer rooms, and highway toll collection, computer rooms, etc., providing one-stop solutions for air conditioners, UPS, cabinets, PDUs, KVMs, and power environment monitoring systems.

  

Technical Features                                                                  

 

Convenient

  • Integrated construction of refrigeration, power distribution, dynamic ring, and cabinet;
  • Standardized scheme, go to engineering design;
  • The factory is fully prefabricated, and the site only needs to be processed in a simple cabinet, and the business can be launched on the same day as soon as possible;
  • No professional computer room is required, and the site environment requirements are low

 

Efficient

  • Close the hot and cold air flow to avoid the mixed flow of air flow, thereby improving the cooling efficiency and reducing the PUE;
  • Optional high-frequency rack UPS, or modular UPS, efficient operation;
  • Near-end cooling to reduce air loss;
  • Adopt DC inverter compressor and stepless speed regulating EC fan, which can run efficiently under load

 

Advantage                                                                               

  • Remote dynamic ring monitoring: It can be connected to multiple sensors to monitor the current, voltage, and power conditions in real time, and to detect environmental conditions such as temperature and humidity, water immersion, vibration, and smoke in the cabinet.
  • Constant temperature control: The system automatically determines the temperature in the cabinet, starts or stops refrigeration, and ensures the stable operation of the equipment.
  • Smart access control: human-computer interaction on the touch screen interface, setting door opening authority, and real-time query of door opening records.

 

Application                                                                               

  • Business outlets (telecommunications, finance, energy, radio and television, retail...)
  • Small companies
  • Branches and networks of large enterprises, governments, education, and medical care
  • Edge Data Center

 

 

Technical Parameter                                                                 

 

ModelEC08EC12EC20ERx
Power3KVA3-6KVA6-30KVA
Number of cabinets0.8m high cabinet, available space 8U1.2m high cabinet, available space 16UStandard 42U cabinet, free space 30U2-10 standard 42U glass door cabinets
Enclosed cabinetGlass door, IP5X, full cold and hot channel sealing
Power supply220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
RefrigerationUnique air duct design, without air conditioner and outdoor unitRefrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring

 