IDC Modular Data Center, Module Data Center High Configuration With
Cooling System And Modular UPS Product Introduction
Coolnet utilizes the existing mature solutions and intelligent
maintenance, and achieves the goal of improving resource
utilization, saving investment costs, and saving energy and
reducing consumption through a number of energy-saving technologies
such as precise power distribution and cold and hot aisle
containment. As an integrated solution, Coolnet has the characteristics of rapid
deployment, energy saving, intelligent management, safety and
reliability. Applications
- Branches and networks of large enterprises
- Government
- Education
| |
Features
| Smart monitoring system Centralized monitoring platform makes us know the data center
environment, power and temperature & humidity status in
real-time. Powerful reporting capabilities. 365 days 7x24-hour unattended, remote monitoring. Minimize IT
operation and maintenance costs. The dynamic environment monitoring system monitors the
infrastructure in an all-round way, alerts abnormal conditions in
time, and is safe and secure.
Modular design Modular and self-contained closed design. The two cabinet in both
sides of hot or cold aisle are one unit, can be installed
separately, provide scalable solutions as demand change or grow. |
Cooling Solution
Air-cooled module solution Applicable to various medium and small data centers, such as:
operator data centers, data centers of various industries (finance,
government, energy, medical, etc.) and other enterprise-level data
centers. Chilled water module It is suitable for all kinds of large and medium data centers with
chilled water hosts, such as: Internet data centers, operator data
centers, data centers in various industries (finance, government,
energy, medical, etc.) and other enterprise-level data centers. | |
Main Basic Unit Introduction
| Aisle Containment -Modular design Adopting modular unit design concept, each unit can be installed
and disassembled independently, and can be closely connected with
adjacent units, which is convenient for disassembly and assembly;
at the same time, it is also suitable for maintenance and
management of other equipment on the channel. Good sealing All unit modules in the hot and cold aisle system are connected
precisely, and the parts are sealed with good sealing tops or
sponge strips, which not only maintains the aesthetics, but also
prevents the leakage of cold air in the cold aisle.
Good light transmission The system is composed of toughened glass with strong light
transmittance.
Power Supply- Modular UPS According to the power supply requirements of large and
medium-sized data centers, a modular UPS solution has been
introduced, which can be flexibly configured with 80-300kVA modular
UPS according to the customer's system power supply requirements.
The module adopts advanced high-frequency switching technology,
fully digital DSP control technology and the world’s leading active
PFC and LLC topologies to achieve high input power factor, accurate
output current sharing performance, and reliable monitoring and
management system. The equipment provides safe, reliable and pure
AC power.
Monitoring System The monitoring system system has the characteristics of simple
configuration, strong access, and high reliability. It can manage
all power, environment, and cooling in data center, integrate
mainstream brand access control, video and other security systems,
through distributed collection, high concurrent processing
capabilities Meet the needs of networked monitoring and management
of multiple computer rooms, allowing data center operation and
maintenance personnel to control the operation safety of the
computer room in real time.
End gate (1) The end doors of the aisle are divided into sliding doors and
double doors, which can be selected according to customer needs. (2) Sliding door size: height × width × depth = 2050mm × 1200mm ×
42mm. The sliding door adopts a sliding structure, the cabinet is used as
the carrier, and the upper and lower rails are installed to ensure
the independence of the closed channel system. The door panel is
bent from 1.5mm cold-rolled steel plate, and tempered glass is
installed in the middle to ensure the visibility of the area in the
passage.
|
Technical Specification
Equipment System | Item | Parameter | System | Dimension | 1200mm enclosed cold/hot aisle dual-row cabinets | | | 1200mm enclosed cold/hot aisle Single-row cabinets | | Rack Quantity | Dual Row Racks:≤48,Single Row Racks:≤24 | Rack | Dimensions | 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U | | Protection Class | IP20 | Enclosed Aisle | Skylight | 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed
skylight | Power Supply and Distribution | Dimension | 600mm(W)*1200mm(D)*2000mm(H) | | UPS Power Supply | 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99 | | Battery | 40AH~240AH/12V Valve Regulated Lead Acid Battery | Cooling | Indoor Unit Size | 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H) | | Cooling Capacity | Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW | | Power Supply | 3Phase 380VAC,50Hz | | Air Supply | Front Supply | | Type | Enclosed Hot/Cold Aisle | | Protection | IP20 | Monitoring System | Monitoring | Temperature and humidity, smoke detection, smart access control,
camera, water leakage alarm | | Equipment monitoring | Power supply, battery, power distribution, air conditioning |