IDC Data Center With Modular UPS System And Skylight Flat Roof

IDC Data Center With Modular UPS System And Skylight Flat Roof

Brand Name COOLNET
Model Number IDC
Certification CE,ISO
Place of Origin CHINA
Minimum Order Quantity 1set
Price 1800-30000USD
Payment Terms T/T, L/C
Supply Ability 300 PCS PER MONTG
Delivery Time 10-25 working days
Packaging Details Packed in plywooden case, standard export package
Condition Brand New
Mounting Floor Standing Units
Type Modular data centers with 19" Standard Server Cabinet
After-sales service provided Engineers available to service machinery overseas
Operating voltage 380/400 VAC,230 VAC,220V
Warranty 1 Year(12 month with no artificial damage)
Product name Modular data center
Refrigerant R22(R407C/R410A)
Application IDC/Large Data Companies/Government/Large Internet Enterprises
Color Black/Grey
Fan type Axial Fan,Direct driven or belt driven,direct driven/belt driven/AC/EC plug fan,AC direct drive fan
Airflow 2000~50000 m3/h
Detailed Product Description

High Configuration IDC Data Center With Modular UPS System And Skylight Flat Roof

 

Product Introduction                                   

The modular data center is mainly composed of cabinets, closed passages, power supply and distribution systems, refrigeration systems, intelligent monitoring systems, integrated wiring and fire protection systems. A single modular data center is configured with N cabinets (including server cabinets, network cabinets, and integrated wiring cabinets). The number of cabinets can be reduced or increased in pairs according to customer needs. Modular data centers are designed to cope with server changes such as cloud computing, virtualization, centralization, and high density, improve data center operation efficiency, reduce energy consumption, and achieve rapid capacity expansion without affecting each other.

 

Feature & Benefits                                        

Characteristics                                                

Modular design

Modular and self-contained closed design. The two cabinet in both sides of hot or cold aisle are one unit,can be installed seperatedly,provide scalable solutions as demand change or grow.

 

Intelligent

Intelligent fire control can be implemented for every top plate. Once fire signal alarm in room, the top plate will open automatically,and fire extinguishing gases can enter the aisle.

 

Convinence

No threshold design,convinent for wheelbarrow.

 

Aesthetic

The window is made of prespective tempering glass with high mechanical strenth,good permeability.The Black coating of cold rolled steel plate borders and cabinet style is consistent and also coorinated with the computer room.

Main Basic Unit Introduction                                                 

 

Monitoring System

The monitoring system system has the characteristics of simple configuration, strong access, and high reliability. It can manage all power, environment, and cooling in data center, integrate mainstream brand access control, video and other security systems, through distributed collection, high concurrent processing capabilities Meet the needs of networked monitoring and management of multiple computer rooms, allowing data center operation and maintenance personnel to control the operation safety of the computer room in real time.

 

Power Supply- Modular UPS
According to the power supply requirements of large and medium-sized data centers, a modular UPS solution has been introduced, which can be flexibly configured with 80-300kVA modular UPS according to the customer's system power supply requirements. The module adopts advanced high-frequency switching technology, fully digital DSP control technology and the world’s leading active PFC and LLC topologies to achieve high input power factor, accurate output current sharing performance, and reliable monitoring and management system. The equipment provides safe, reliable and pure AC power.

Air Supply Method                                                  

Technical Specification                                                     

Equipment SystemItemParameter
SystemDimension1200mm enclosed cold/hot aisle dual-row cabinets
  1200mm enclosed cold/hot aisle Single-row cabinets
 Rack QuantityDual Row Racks:≤48,Single Row Racks:≤24
RackDimensions600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U
 Protection ClassIP20
Enclosed AisleSkylight300mm / 600mm wide turning skylight,Flat roof skylight,Fixed skylight
Power Supply and DistributionDimension600mm(W)*1200mm(D)*2000mm(H)
 UPS Power Supply380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99
 Battery40AH~240AH/12V Valve Regulated Lead Acid Battery
CoolingIndoor Unit Size300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H)
 Cooling CapacityCooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW
 Power Supply3Phase 380VAC,50Hz
 Air SupplyFront Supply
 TypeEnclosed Hot/Cold Aisle
 ProtectionIP20
Monitoring SystemMonitoringTemperature and humidity, smoke detection, smart access control, camera, water leakage alarm
 Equipment monitoringPower supply, battery, power distribution, air conditioning