High Configuration High Efficient Modular Data Center With In-Row
Precision AC Units Product Introduction
In response to the development trend of cloud computing,
virtualization, centralization, and high-density servers,
standardization is becoming a popular trend in the field of modern
data centers. coupling. Integrate subsystems such as power supply
and distribution, cooling, cabinets, air enclosures, integrated
wiring, and dynamic environment monitoring to improve the overall
operation efficiency of the data center, achieve rapid deployment,
flexible expansion, save costs, occupy space, and improve the
performance of key infrastructure , efficiency and reliability. Feature & Benefits
| |
Advantages
| Intelligent Fire Safe System Alerts personnel and drops ceiling panels based on temperature to
enable fire suppressions system in the room toextinguish the fire.
Once fire signal alarm in room, the top plate will open
automatically, and fire extinguishing gasesan enter the aisle. Efficiency Flexibility Increases the capacity of the air conditioner by supplying a warmer
return air temperature. It supports for varying aislewidths, rack
heights, rack depths, and single rows. Supports hot and cold aisle
containment. Automatical Door Structure One-way locking door or safe slide doors secures the hot aisle
while allowing for quick exit in case of emergency, thesliding door
can be closed automatically, can be installed door access system
and can be opened from inside to outside if an emergency occurs. |
Main Basic Unit Introduction
Rack Part The modular data center can be configured with N cabinets,
including server cabinets, network cabinets and integrated wiring
cabinets. Appearance of the cabinet The cabinet size of the modular data center configuration is
uniform, the cabinet conforms to the IEC60297-1 standard, and the
front and rear air ducts are adopted. The appearance of the cabinet
is shown in the figure. Cabinet Charaectristic (1) The ventilation rate of the front and rear doors is 70%. (2) Two vertical PDUs can be installed at the rear of the cabinet. (3) The exact position of each "U" is marked on the vertical
installation column of the cabinet. The front door, back door and
side panels of the cabinet can be locked and can only be opened
with the provided special key Aisle Containment -Modular design The Aisle of the modular data center is mainly composed of end
doors and skylights. End gate (1) The end doors of the aisle are divided into sliding doors and
double doors, which can be selected according to customer needs. (2) Sliding door size: height × width × depth = 2050mm × 1200mm ×
42mm. The sliding door adopts a sliding structure, the cabinet is used as
the carrier, and the upper and lower rails are installed to ensure
the independence of the closed channel system. The door panel is
bent from 1.5mm cold-rolled steel plate, and tempered glass is
installed in the middle to ensure the visibility of the area in the
passage. Adopting modular unit design concept, each unit can be installed
and disassembled independently, and can be closely connected with
adjacent units, which is convenient for disassembly and assembly;
at the same time, it is also suitable for maintenance and
management of other equipment on the channel. Good sealing All unit modules in the hot and cold aisle system are connected
precisely, and the parts are sealed with good sealing tops or
sponge strips, which not only maintains the aesthetics, but also
prevents the leakage of cold air in the cold aisle. | |
Technical Specification
Equipment System | Item | Parameter | System | Dimension | 1200mm enclosed cold/hot aisle dual-row cabinets | | | 1200mm enclosed cold/hot aisle Single-row cabinets | | Rack Quantity | Dual Row Racks:≤48,Single Row Racks:≤24 | Rack | Dimensions | 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U | | Protection Class | IP20 | Enclosed Aisle | Skylight | 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed
skylight | Power Supply and Distribution | Dimension | 600mm(W)*1200mm(D)*2000mm(H) | | UPS Power Supply | 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99 | | Battery | 40AH~240AH/12V Valve Regulated Lead Acid Battery | Cooling | Indoor Unit Size | 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H) | | Cooling Capacity | Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW | | Power Supply | 3Phase 380VAC,50Hz | | Air Supply | Front Supply | | Type | Enclosed Hot/Cold Aisle | | Protection | IP20 | Monitoring System | Monitoring | Temperature and humidity, smoke detection, smart access control,
camera, water leakage alarm | | Equipment monitoring | Power supply, battery, power distribution, air conditioning |