Modular Data Centers With High Integrated Monitoring System For
Finance And Government Product Introduction
Standardization is becoming a popular trend in the modern data
center space, and the first place for data center standardization
is racking systems and containment solutions. Cooling
infrastructure, rack density, cooling efficiency, etc., will vary
from site to site. As a result, flexible, easy-to-install,
adaptable, and pre-configured custom server racks and network
enclosures save you cost, space, and improve the performance,
efficiency, and reliability of your critical infrastructure. Benefits
| |
Characteristics
| 1. Realize phased construction and easy scalability The modular data center integrates modular components such as
terminal refrigeration, terminal power distribution, and terminal
wiring. On the basis of reducing the initial investment, it
realizes the on-demand deployment of the data center, avoids the
idle waste of fixed assets, and ensures the large-scale data
center. The infrastructure configuration of any IT space reaches
the best condition. The micro-module data center significantly
reduces the cost during the life of the data center. For the needs
of large-scale IDC construction, at any time node in the later
period, customers require rapid increase in business needs, and the
use of micro-module data centers is easy to quickly expand.
2.Green energy saving At present, the cost of electricity usage in data centers accounts
for the largest proportion of life-time TCO. The modular data
center realizes the on-demand power supply and cooling of IT
equipment, so that the capacity of the power supply and cooling
system is more matched with the load demand, thereby improving work
efficiency and reducing over-configuration. The micro-module power
conversion rate is as high as 95%. Due to the standardized
interface and micro-module architecture, it can greatly save power
and achieve system energy saving.
|
Main Basic Unit Introduction
Cooling System - In Row Air Conditioning Unit Inverter In Row air conditioners are tailor-made high-density
cabinets, adopts advanced frequency conversion technology and uses
the environmentally friendly refrigerant R410A. The output cooling
capacity is adjusted in real time according to the change of the
detected load, to avoid frequent start and stop, and to ensure the
temperature of the computer room environment. Compared with fixed frequency air conditioners, the annual energy
saving rate of variable frequency inter-train air conditioners can
reach 29%. Monitoring System The monitoring system system has the characteristics of simple
configuration, strong access, and high reliability. It can manage
all power, environment, and cooling in data center, integrate
mainstream brand access control, video and other security systems,
through distributed collection, high concurrent processing
capabilities Meet the needs of networked monitoring and management
of multiple computer rooms, allowing data center operation and
maintenance personnel to control the operation safety of the
computer room in real time. | |
Features
| Energy saving and high efficiency Efficient power supply and distribution, cooling close to the heat
source, effectively reducing the PUE value of the module, isolating
cold and hot air flow, eliminating ineffective air circulation and
eliminating local hot spots Through integrated management of
modules, coordinated operation and improved performance of
functional components. On-demand expansion •Standardized, modular and integrated design, saving 30% of
construction cost. Cabinet expansion is as simple as building
blocks, and computing power grows as needed. •Software-defined infrastructure, excellent resource elastic
scalability. •Meet business elastic scaling requirements and save 40% of initial
investment. Simple operation and maintenance • Centralized monitoring of computer room infrastructure, IT
infrastructure and cloud platform. Multi-cloud management of
physical and virtual resources. • Automatic fault location, automatic isolation, efficient
operation and maintenance. •24-hour active inspection, cloud service support. |
Air Supply Method
Technical Specification
Equipment System | Item | Parameter | System | Dimension | 1200mm enclosed cold/hot aisle dual-row cabinets | | | 1200mm enclosed cold/hot aisle Single-row cabinets | | Rack Quantity | Dual Row Racks:≤48,Single Row Racks:≤24 | Rack | Dimensions | 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U | | Protection Class | IP20 | Enclosed Aisle | Skylight | 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed
skylight | Power Supply and Distribution | Dimension | 600mm(W)*1200mm(D)*2000mm(H) | | UPS Power Supply | 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99 | | Battery | 40AH~240AH/12V Valve Regulated Lead Acid Battery | Cooling | Indoor Unit Size | 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H) | | Cooling Capacity | Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW | | Power Supply | 3Phase 380VAC,50Hz | | Air Supply | Front Supply | | Type | Enclosed Hot/Cold Aisle | | Protection | IP20 | Monitoring System | Monitoring | Temperature and humidity, smoke detection, smart access control,
camera, water leakage alarm | | Equipment monitoring | Power supply, battery, power distribution, air conditioning |