Large Air Volume And Cooling Capacity Precise Air Conditioners For
Industrial Test Room Product Introduction Precision air conditioners are designed for data centers, computer
rooms, and network centers. All series of precision air
conditioners for computer rooms use modular energy-saving planning
principles, and different types of special precision air
conditioners are announced according to different users. The
electronic equipment in the communication room releases a lot of
sensible heat. According to the characteristics of the room, the
high sensible heat ratio of 0.9 or more is achieved. When used in
the environment of the computer room, it consumes about 20-30% of
the energy consumption compared with ordinary comfort air
conditioners, and thus avoids excessive Dehumidification and air
supply are foggy. Applications Computer room and data center Switch room and mobile center station in telecommunication High-tech environment and lab Industrial automation control room and precision manufacturing
workshop Standard test room and calibration center UPS and battery room Test room in hospital Biochemical culture chamber | |
Main Parts
| DC inverter compressor Using R410A environmentally friendly refrigerant, DC frequency
conversion, high efficiency and energy saving; Dynamic cooling to adapt to the rapidly changing heat load of the
computer room; Save energy at low loads, improve energy efficiency, and reduce
Opex throughout the life cycle; Greatly reduce compressor start and stop times and improve system
reliability; Brushless DC maintenance-free motor, easy to operate and maintain; Soft start function to reduce the impact on the power distribution
system; EC fan The use of electronically commutated synchronous EC electrodes can
save energy by 20% to 30%; Automatically adjust the fan speed according to cooling demand or
wind pressure, and provide air volume on demand; Soft start function, low starting current; The impeller is made of aviation-grade engineering composite
material, which is light in weight, efficient and reliable; Dual electronic expansion valve design Smoothly adjust the throttle opening, and cooperate with the DC
inverter compressor to achieve energy saving; Wide adjustment range, reduce superheat and improve energy
efficiency ratio; Accurate matching of cooling capacity and load; Fast response speed to achieve precise cooling; Frequency conversion speed owl condensing fan Frequency conversion control, high efficiency and energy saving; Owl fan, low noise; Stainless steel connectors and marine grade corrosion-resistant
aluminum; Single/double refrigeration circuit design, centralized
condensation scheme can be selected; |
Advantages
- High reliability, high energy saving rate, high adaptability, low
cost throughout life
- The air-conditioning unit adopts a modular design, the compressor
and evaporator of a refrigeration system are in the same module,
and the transportation and handling module is disassembled.
- The indoor fans are equipped with EBM/Xerox Bai and other brand EC
fans as standard, and the fan system saves more than 30% energy
than conventional air conditioning units.
- The same external pressure requirement. The inner fan can be
operated with stepless speed regulation, and the temperature
difference between the supply and return air, the temperature of
the return air and the temperature of the outlet air can be
selected for control.
- Standard EEV dual electronic expansion valve, low-load
dehumidification
- Large area V-shaped evaporator, high air volume, high sensible heat
ratio
- Large humidification capacity, suitable for poor water quality, low
maintenance
- Frequency conversion series units are equipped with oil separator
as standard
- The power consumption per 1kg/h of humidification should not exceed
0.8kW to achieve energy-saving operation.
| |
Technical Parameters
Model: CYA | S20D/U | S23D/U | S26D/U | S28D/U | S31D/U | S35D/U | S40D/U | S45D/U | Power Supply | 380V 3Ph-50HZ | Air Discharge | Upflow/Downflow | Cooling Capacity :24℃/50%RH | Total Capacity | KW | 20.5 | 23.5 | 26.8 | 28.3 | 31.5 | 35.5 | 40.2 | 45.6 | Sensible | KW | 18.9 | 21.6 | 24.2 | 26.1 | 28.9 | 33.2 | 37.6 | 42.2 | AEER | w/w | 3.7 | 3.6 | 3.6 | 3.7 | 3.7 | 3.7 | 3.7 | 3.6 | Air Flow | m3/h | 6830 | 7650 | 7580 | 8500 | 9200 | 9800 | 10600 | 12000 | Compressor Hermetic scroll | Refrigerant | R407C | Compressor quantity | PC | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | Fan Section Centrifugal fan (Optional EC) | Fan quantity | PC | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | Rated current | A | 2.5 | 2.5 | 2.8 | 3.2 | 3.5 | 4.1 | 4.4 | 4.9 | Rated power | W | 1050 | 1100 | 1200 | 1300 | 1320 | 2000 | 2150 | 2400 | Reheat Capacity | KW | 6 | 6 | 6 | 6 | 9 | 9 | 9 | 9 | Reheat Material | PTC | Humidifier Section Electrode type | Capacity | Kg/h | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 13 | Rated Current | A | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 15 | Condensor Model | | 58 | 58 | 80 | 80 | 100 | 120 | 150 | 150 |
Certificates
Factory Details
Packing & Delivery
Case
|