Front Flow CRAC Units Small Enthalpy Difference Cooling System

Front Flow CRAC Units Small Enthalpy Difference Cooling System

Brand Name Coolnet
Model Number M13 M20
Certification CE/ISO9001
Place of Origin China
Minimum Order Quantity 1
Price $1000.00-5000.00/set
Payment Terms T/T
Supply Ability 1000-5000/set/month
Delivery Time 4W
Packaging Details WOODED
Cooling Capacity 5-15KW
Color Black/Grey/White/Other custom colors
Mounting Floor Standing Units
Voltage 380/400 VAC,230 VAC,220V
Application Computer Room,Printing factory/cinema/supper marekt/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity
Power 3N-380V-50Hz,220v/50hz/60hz
Air Flow Front Flow/Down Ward Flow
Product Precision air conditioning unit/ Data center cooling unit /Computer room unit /Close control unit
Detailed Product Description

CRAC Units Standard Electric Expansion Value Small Enthalpy Difference Cooling System

 

Product Introduction                                  

Coolnetpower is one of the professional manufacturers in the refrigeration field. In recent years, the electronic system design of Internet data centers and industrial automation computer rooms is highly complex and compact, and the control requirements for special temperature, humidity, high temperature and other operating environments are very high. However, some companies and enterprises have small computer rooms and large amounts of heat. Using large precision air conditioners to dissipate heat will waste operating costs, and using household air conditioners to dissipate heat will waste energy. In response to this situation, the Cool-smart precision air conditioner newly developed by the Coolnet R&D team has the characteristics of small footprint, small enthalpy difference, large air volume, high reliability and strong energy saving, and has been widely welcomed.

 

 

Technical Features                                                

Air supply system
Up air supply system, indoor hot air is sucked in through the return air outlet of the Cool-smart units, and then sent to the air by the fan after passing through the coil cap or duct. The upper air system G4 filter is installed in the return air outlet of the unit.
Downward air supply system, indoor hot air is sucked in through the G4 filter on the upper end of the unit, and then passed to the bottom platethrough the coil by the fan of the unit.

 

Evapotator
Evaporator coils are constructed of copper tubes and aluminum fins and are designed for the high sensible heat requirements of electronic equipment. The indoor air circulation is completed by a centrifugal fan with a high-efficiency, low-noise, backward-inclined outer rotor, which has been adjusted for dynamic balance before leaving the factory. The fan is built with self-adjusting bearings and permanent grease, so there is no need for separate bearing maintenance during its lifetime.

 

Compressor

The compressor is installed in the indoor unit, which is suitable for the all-weather operation of the air conditioner in the communication room, which is more beneficial to the life of the compressor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Scope of Application                                              

 

  • IT Equipment Room
  • Small Data Center
  • Industrial Clean Room
  • Constant Temperature and Humidity Process Workshop
  • Laboratory
  • Electric Power Equipment Room
  • Railway Subway Machine Room
  • Base Station and Small Telecom Switch Room
  • Medium&Small Telecom Switch Room

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical Parameter                                                     
ModelM04M06M08M13M16M20
Power Supply220V1Ph-50Hz380V3Ph-50Hz
Air dischargeUp Front/Down
Technical Data Sheet
AC FanTotal cooling capacity-KW4.26.47.512.516.820.2
Sensible cooling capacity-KW3.95.86.911.315.318.3
Unit FLA-A(heating, humidifying type)20.025.016.822.023.528.6
Compressor Quantity1
Fan Quantity1
Air Volume-m3/h160019002300360051006500
Heater Capacity-KW3.03.06.06.06.06.0
Humidification-kg/h333366
Power of humidifier-KW2.32.32.32.34.54.5
Outdoor Condenser
ModelSCA020SCA020SCA030SCA030SCA050SCA050
Standard unit operating temperature range-℃-15-45℃
Low Temperature Components Operating Temperature Range-℃-40-45℃

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Certificates                                                  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

     

 

 

 

Factory Details                                                 

 

Packing & Delivery

 

Cases                                                             

 

 

 

 

 

 

Product Tags: 15KW CRAC Units   Electric Expansion Value CRAC Units   Front Flow CRAC Units  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Hefei Coolnet power Co., ltd
Subject:
Message:
Characters Remaining: (80/3000)