Optional Air Discharge Environmental Friendly PAC Systems For Large
Storage Rooms Products Introduction
With the development of the Internet and information technology,
the amount of data processing and storage has continued to grow,
and this growth has also led to a continuous increase in the heat
density of the data center, and has brought about dynamically
changing load requirements at different time periods. Coolnet
precision air conditioners can be combined with microprocessor
systems to provide full control of computer rooms and precision
equipment workshops, including control of ambient temperature,
humidity and air cleanliness in these locations. The precision air
conditioner can control the temperature and relative humidity of
the equipment room within plus or minus 1 degree Celsius and 5%,
thus greatly improving the life and reliability of the equipment. Applications
- Large, medium and small exchange room, Large data center
- Small and medium computer rooms, equipment rooms, power rooms
- Outdoor electronics, Communication equipment rooms
- Substations, Laboratories, Testing rooms, Storage rooms
| |
Product Inner Details
| DC inverter compressor Using R410A environmentally friendly refrigerant, DC frequency
conversion, high efficiency and energy saving; Dynamic cooling to adapt to the rapidly changing heat load of the
computer room; Save energy at low loads, improve energy efficiency, and reduce
Opex throughout the life cycle; Greatly reduce compressor start and stop times and improve system
reliability; Brushless DC maintenance-free motor, easy to operate and maintain; Soft start function to reduce the impact on the power distribution
system; EC fan The use of electronically commutated synchronous EC electrodes can
save energy by 20% to 30%; Automatically adjust the fan speed according to cooling demand or
wind pressure, and provide air volume on demand; Soft start function, low starting current; The impeller is made of aviation-grade engineering composite
material, which is light in weight, efficient and reliable; Dual electronic expansion valve design Smoothly adjust the throttle opening, and cooperate with the DC
inverter compressor to achieve energy saving; Wide adjustment range, reduce superheat and improve energy
efficiency ratio; Accurate matching of cooling capacity and load; Fast response speed to achieve precise cooling; Frequency conversion speed owl condensing fan Frequency conversion control, high efficiency and energy saving; Owl fan, low noise; Stainless steel connectors and marine grade corrosion-resistant
aluminum; Single/double refrigeration circuit design, centralized
condensation scheme can be selected; |
Advantages
Energy saving and high efficiency Save a lot of energy consumption in a reasonable and feasible way,
and make full use of natural resources; The unit uses a high-efficiency fan and a fully enclosed compressor
system to reduce operating costs and always pay attention to energy
efficiency. Multiple air supply The air supply method of the air-conditioned room depends on the
source and distribution characteristics of the heat in the room.
According to the dense arrangement of equipment in the computer
room, the number of cables and bridges, and the wiring method, the
air supply method of the air conditioner is divided into lower
delivery, upper return, top feed back, top feed side back, side
feed side back. Static pressure box air supply The air conditioner in the computer room usually does not use
pipes, but uses the space at the lower part of the raised floor or
the upper part of the ceiling as the return air of the static
pressure box. static pressure is equal. | |
Technical Parameters
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | Power Supply | 380V 3Ph-50HZ | Air Discharge | Upflow/Downflow | Cooling Capacity :24℃/50%RH | Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 | Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 | AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 | Compressor Hermetic scroll | Refrigerant | R407C | Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | Fan Section Centrifugal fan (Optional EC) | Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 | Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 | Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 | Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 | Material | PTC | Humidifier Section Electrode type | Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | Condenser Model | | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |