All-In-One Solution For Data Center Cooling System Container
Integrated Solution With Precision Air Conditioning Unit Product Introduction
Coolnet modular data center can flexibly adopt the layout of
double-row cabinets + cold/hot aisle or single-row cabinets +
cold/hot aisle according to user site conditions. Under the two
structural layouts, all subsystems such as cabinets, channels,
power supply and distribution, refrigeration, security,
environmental monitoring and management, and wiring can be
integrated according to user needs, providing customers with new
data of rapid deployment, high efficiency and energy saving,
compact space, and flexible expansion Central solution. Benefits
| |
Features
| Flexible Reliable Standardized Solution (Modular Design &Fast
Deployment) Two cabinets and roof ceiling form a unit of self-contained closed
space/aisle.it is called hot or cold aisle containment, can be
installed seneratedly.provide scalable solutions as demand change
or erow. Modular desion nrovides scalable solutions to add cooling
as demand increases. Intelligent Fire Safe System Alerts personnel and drops ceiling panels based on temperature to
enable fire suppressions system in the room to extinguish the
fire.Once fire signal alarm in roomthe top plate will open
automatically and fire extinguishing gases can enter the aisle.
Efficiency &Flexibility Increases the capacity of the air conditioner by supplying a warmer
return air temperature. It supports for varying aisle widths, rack
heights, rack depths, and single rows. Supports hot and cold aisle
containment.
Automatical Door Structure One-way locking door or safe slide doors secures the hot aisle
while allowing for quick exit in case of emergency, the sliding
door can be closed automaticallvcan be installed door access svstem
and can be onened from inside to outside if an emergency occurs.
Customization Providing customized solutions for your special requirements can be
rapid deployment in your projects.
|
Advantage
High reliability standard module Modular data center adopts modularization, standardization and high
reliability design, which makes the whole system highly stable.
According to customer needs and actual conditions, N+1, N+X, 2N,
etc. can be provided in the configuration of power supply and
cooling core equipment. The design scheme is safe and reliable, and
meets the standards of various levels from Tier3 to Tier4. Rapid deployment, greatly shortening the construction period The micro-module data center improves the efficiency of planning
and design, and can reasonably configure the system architecture
according to IT business needs, such as the arrangement of the
cabinets of the module units, the selected power supply and
distribution equipment, cooling solutions, monitoring systems,
etc.; Fast delivery, standardized components, reduce on-site
assembly workload, and speed up installation; micro-modules can be
assembled and pre-tested in the factory, which ensures the
debugging speed and reliability of the system; modular design,
combined with infrastructure + IT equipment All-in-one delivery
reduces data center deployment cycles to weeks. Green energy saving Data center power usage costs currently account for the largest
portion of lifetime TCO. Modular data centers realize on-demand
power supply and cooling of IT equipment, so that the capacity of
the power supply and cooling system is more matched with the load
demand, thereby improving work efficiency and reducing
over-provisioning. The micro-module power conversion rate is as
high as 95%. Due to the use of standardized interfaces and
micro-module architecture, it can greatly save power and achieve
system energy saving. The modular data center adopts closed and isolated cold aisles, so
that the hot and cold air flows do not interfere with each other,
which avoids the heat island effect caused by the crosstalk of the
air flow, and avoids the loss of air volume and cooling capacity.
At the same time, the use of inter-column air conditioners and the
design of the near heat source of the refrigeration equipment
improve the cooling efficiency, solve the problem of local hot
spots, and reduce the operating cost of the data center. | |
Technical Specification
Equipment System | Item | Parameter | System | Dimension | 1200mm enclosed cold/hot aisle dual-row cabinets | | | 1200mm enclosed cold/hot aisle Single-row cabinets | | Rack Quantity | Dual Row Racks:≤48,Single Row Racks:≤24 | Rack | Dimensions | 600mm(W)*1200mm(D)*2000mm(H), can be customerized,42U | | Protection Class | IP20 | Enclosed Aisle | Skylight | 300mm / 600mm wide turning skylight,Flat roof skylight,Fixed
skylight | Power Supply and Distribution | Dimension | 600mm(W)*1200mm(D)*2000mm(H) | | UPS Power Supply | 380VAC/400VAC/415VAC(3Phase 5Wire),50/60Hz,PF=0.99 | | Battery | 40AH~240AH/12V Valve Regulated Lead Acid Battery | Cooling | Indoor Unit Size | 300mm(W)*1200mm(D)*2000mm(H),600mm(W)*1200mm(D)*2000mm(H) | | Cooling Capacity | Cooling:20~40KW,Chilled water :20~70KW,Chilled water :20~70KW | | Power Supply | 3Phase 380VAC,50Hz | | Air Supply | Front Supply | | Type | Enclosed Hot/Cold Aisle | | Protection | IP20 | Monitoring System | Monitoring | Temperature and humidity, smoke detection, smart access control,
camera, water leakage alarm | | Equipment monitoring | Power supply, battery, power distribution, air conditioning |