20-200kVA Modular Uninterruptible Power Supply For Computer Room
|
Modular Uninterruptible Power Supply For Computer Room 20-200kva
The CNM series modular UPS provides the most compact footprint of
less than 2㎡ with maximum capacity of 900kVA.With best reliability
and high performance, it has been leading the domesticmarket for
years. Modular UPS System Features ♦Extendibility: The greatest difference between a modular UPS and a traditional
single-unit UPS is that it is not necessary to add an identical
unit having the same capacity or replace the mainframe with one
having a higher capacity when the capacity of the entire system
needs to be extended, In stead the capacity be easily extended by
increasing the number of modules.
♦Availability: 1.Its Mean Time between Failures (MTBF) is 1.5 times of the MTBF of
the traditional UPS. Its Mean Time between Component Failures (
MTBCF) is 3 times of the MTBCF of traditional UPS. ♦Hot-plug performance: The power module and monitoring & communication module of the system can be plugged in or plugged out online at will. This will shorten the time that technicians have to spend on maintenance and repairs, greatly simplify the repairing procedures, and provide more conveniences and safety of work.
♦Redundancy: All power modules in the system equally share the load of the system. Upon a failure of any module, other modules will automatically share the load of this failed module. Each module of the system can run independently. No system controller centralized control of system. An N+1~N+X redundancy system can be constructed as required, reducing the risk factors of the system itself and its load and comprehensively prolonging the duration of UPS protection of the external load. ♦Environmental friendliness: The total harmonic distortion (THDI) of the input of the UPS system is only 3%, which is far lower than the 33% input harmonic distortion of the 6-pulse silicon controlled rectifier of the traditional single-unit UPS and the 13% input harmonic distortion of the 12-pulse silicon controlled rectifier. Under a linear load, the output THDI is lower than 2%. The harmonic inference against the power network is minimized and the load and power losses of the power network are effectively reduced. With its excellent input parameters and characteristics of a pure resistance with respect to the commercial power network, this is an ideal pollution-free UPS which can be easily fitted to the commercial power network and generators and is close to the load-bearing capacity of the actual network.
Data Sheet
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: 20-200kVA modular uninterruptible power supply ISO data center uninterruptible power supply 20-200kVA computer room ups |
![]() |
Rack-Mounted Online UPS System for Server Rooms and Data Centers |
![]() |
Rack-Mounted Double Conversion UPS System for Edge Computing Environments |
![]() |
RackMount UPS High Efficiency Power Backup for Server Rooms |
![]() |
Rack-Mounted UPS 5kVA Online Double Conversion for Data Center Equipment |
![]() |
Rack Mounted UPS With Superior Power Stability And Efficiency For Data Centers And Network Systems |
![]() |
Coolnet Rack-Mounted UPS Power Backup System High Efficiency And Reliable Protection For Critical Equipment |