China Precision Air Conditioning Units manufacturer
Hefei Coolnet power Co., ltd
Hefei Coolnet power Co., ltd
6
Home > Products > In Row Air Conditioning Unit >

In Row Cooling Data Room Air Conditioning Unit 40kW

In Row Cooling Data Room Air Conditioning Unit 40kW

Brand Name COOLNET
Model Number CYA,M08,CR012
Certification CE,ISO
Place of Origin CHINA
Minimum Order Quantity 1set
Price 1800-30000USD
Payment Terms T/T, L/C
Supply Ability 300 PCS PER MONTG
Delivery Time 10-25 working days
Packaging Details Packed in plywooden case, standard export package
Cooling capacity 20-50KW
Condition New
Mounting Floor Standing
Type In Row Cooling
Product name Inrow Precision air conditioning
Refrigerant R410A
Application Computer Room,Printing factory/cinema/supper marekt/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity
Color Grey
Fan type Axial Fan,Direct driven or belt driven,direct driven/belt driven/AC/EC plug fan,AC direct drive fan
Power 3N-380V-50Hz,220v/50hz/60hz
Airflow 2000~50000 m3/h
Voltage 380v/220v,220V/380V,380V/415V
Detailed Product Description

Data Room Precision Air Conditioning Unit In Row Cooling Solution 40kw

 

Product Introduction                                   

Inrow cooling precisely cools and conditions air in close proximity and is targeted cooling at the banks of server cabinets that fill the data center. They can be installed on the floor or suspended from overhead making them closer to the actual rack. This setup offers both capacity and efficiency gains. Neither cool air nor warm exhaust air has far to travel, allowing the units to dissipate high heat loads quicker and allows a more scalable approach to cooling your data center.

 

Feature & Benefits                                     

Cooling on demand

  • DC frequency conversion, 10%-100% refrigeration capacity stepless adjustment, high efficiency at part load;
  • High-efficiency EC fan, close to the rack to supply air, the fan can save 20%-30%;
  • The outdoor fan frequency conversion speed regulation, control the air volume according to the demand;
  • Stable dehumidification under a load as low as 10%, excellent performance

 

Safe and reliable

  • The start-up current is small, which can reduce the impact on the power grid;
  • Expert self-diagnosis and fault warning function to ensure operation;
  • Fan N+1 redundant configuration, to avoid equipment operation obstacles caused by unexpected situations;
  • Dual power input, safer and more reliable

Scope of Applications                         

  • Mobile base station
  • Outdoor rooms
  • Satellite ground station
  • Paging machine room
  • Network management center
  • Small computer room
  • Small laboratory
  • Wine cellar

 

Air Supply Method                               

 

 

Technical Parameter                                     

ModelCRA013ACRA020ACRA040ACRA050ACRA060A
Air supplyFront/SideFront/SideFrontFrontFront
Power supply380VAC/3Ph/50Hz
Cooling capacity-KW13.226.742.653.363.9
Sensible cooling-KW13.226.742.653.363.9
Compressor
RefrigerantR410A
Quantity1
Fan
Fan typeEC Centrifugal fan
Quantity45233
Air volume-m3/h3200500088001100012500
Heater
Heat typePTC    
Capacity-KW23666
Humidification
Capacity-KW11.5333

 

Certificates                                          

 

Factory Details                                                

 

Packing and Delivery                                         

 

Cases                                                               

 

 

 

 

 

 

Product Tags: 40kW data room air conditioning   data room air conditioning Unit   40000W in row air conditioning  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Hefei Coolnet power Co., ltd
Subject:
Message:
Characters Remaining: (80/3000)