Brand Name AMPFORT
Model Number TMST20A 350V
Certification UL,TUV
Place of Origin Dongguan,Guangdong,CN
Minimum Order Quantity 10000PCS
Price 0.06 USD/PC
Payment Terms T/T, Western Union
Supply Ability 10,000,000PCS per week
Delivery Time 10 workdays
Packaging Details Tape,1000pcs per box,10 boxes per carton,6kg/carton,44*35*22cm
Name Subminiature Fuse
Current Rating, Amp 20A
Voltage, AC 350V
Characteristic Slow Blow
Voltage, DC 100V
RoHS Compliant Yes
Packaging Tape
Fuse Type Board Mount (Cartridge Style Excluded)
Type Radial, Box
Breaking Capacity 35A
Operating Temperature -55°C ~ 125°C
Approval Agency UL,CUL,TUV
Max Voltage Drop 85mV
I2TMelting Integral 960 A2S
P/N TMS2200A
Response Time Slow blow
Detailed Product Description

 

Micro Box Type Radial Leaded Time Lag Subminiature Fuse TMS T20A 350V With UL TUV Certifications

 

Description Of The Time Lag Subminiature Fuse

 

Subminiature, radial lead, High I2 t, time-lag design, rated 350VAC, 72 DC, up to 20A, Approved by UL,CUL,TUV and complied with UL 248-Standards:In accordance with IEC60127-1, IEC60127-3 Standard sheet4, GB9364.1-1997, GB9364.3-1997.

 

 

Certification Of The Time Lag Subminiature Fuse

 

Agency

Ampere Range

Agency File Number

c UL us50mA ~ 20AE340427 (JDYX )(JDYX7)
TUV50mA ~ 20AJ50466477
c UR us50mA ~ 6.3AE340427(JDYX8) (JDYX2)

 

 

Features Of The Time Lag Subminiature Fuse

 

- High I2 t, High amp ratings to 20A

- Time lag (350 VAC)

- Meet UL 248-14

- Wide operating temperature range

- Bulk and Tape & Ammo packing available

- Full compliance with EU Directive 2011/65/EU and amending directive 2015/863

- Halogen Free and Lead Free

- UL,CUL,TUV

 

 

Application Of The Time Lag Subminiature Fuse

 

Provide individual protection for components or internal circuits.

- Power supplies

- Battery chargers

- Consumer Electronics

- Adapter

- Industrial Controllers

 

 

Part Numbering Of The Time Lag Subminiature Fuse

 

Breaking Capacity: 35A or 10In whichever is greater.
After the test, the insulation resistance value is greater than 0.1ΜΩ

 

Part No.

Ampere

Rating

Voltage

Rating

Max Voltage

Drop (mv)

I2TMelting

Integral(A2.S)

TMS0050A50mA350V16000.015
TMS0063A63mA350V16000.016
TMS0080A80mA350V15000.017
TMS0100A100mA350V15000.02
TMS0125A125mA350V7600.10
TMS0160A160mA350V5000.15
TMS0200A200mA350V2600.21
TMS0250A250mA350V2400.48
TMS0315A315mA350V2200.78
TMS0400A400mA350V2001.22
TMS0500A500mA350V1902.11
TMS0630A630mA350V1802.88
TMS0800A800mA350V1603.92
TMS1100A1A350V1405.77
TMS1125A1.25A350V1308.34
TMS1160A1.6A350V12013.60
TMS1200A2A350V10026
TMS1250A2.5A350V10042
TMS1300A3A350V10045
TMS1315A3.15A350V10090
TMS1350A3.5A350V100100
TMS1400A4A350V100120
TMS1500A5A350V100170
TMS1630A6.3A350V100290
TMS1800A8A350V100320
TMS2100A10A350V95450
TMS2120A12A350V95460
TMS2150A15A350V85480
TMS2160A16A350V85515
TMS2200A20A350V85960

 

 

Operating Characteristics Of The Time Lag Subminiature Fuse

 

% of Ampere Rating(In)

Blowing Time

150%* In60 min Minimum
210%* In2 min Max
275%* In400 ms~10 s
400%* In150 ms~3 s
1000%* In20 ms~150 ms

 

 

Selection Table Of The Time Lag Subminiature Fuse

 

 

 

 

 

Can fast-acting fuse replaced by slow blow fuse ?

 

The two can replace each other in some circuits with less stringent requirements, but cannot replace each other in circuits with strict requirements.
T2A is a slow blow fuse and F2A is a fast blow fuse. The main difference between a slow-blow fuse and a fast-blow fuse is its ability to withstand instantaneous pulse current, which means that it can resist the impact of surge current when switching on and off without moving, thus ensuring the normal operation of the equipment, so slow-blow fuses Often referred to as a surge fuse.
From a technical point of view, slow-blow fuses have a larger melting heat value and require a larger amount of energy to fuse. Therefore, for fuses with the same rated current, slow-blow fuses are much more resistant to pulses than fast-blow fuses.
Since the thermal energy value of the slow-blow fuse is larger than that of the fast-blow fuse of the same specification, the fusing time will be slower than that of the fast-blow fuse when an overcurrent occurs in the circuit.
Once the circuit fails, the overcurrent will not disappear by itself. The energy of the continuous overcurrent will greatly exceed the thermal energy value of the fuse. No matter what kind of fuse will be blown, the time difference between slow blowing and fast blowing is important for its protection requirements. It is not very important, only when there are sensitive devices in the protected circuit that need to be protected, slow fuse will have an impact on the protection performance.

Because of these differences, slow-blow fuses and fast-blow fuses are used in different circuits: pure resistive circuits (no or little surge) or circuits that need to protect sensitive and valuable components such as ICs must use fast-blow fuses; For capacitive or inductive circuits (there is a surge when switching on and off), it is best to use slow-blow fuses in the input/output parts of the power supply; in addition to protecting IC circuits, slow-blow fuses can be used in most situations where fast-blow fuses are used. It improves the anti-interference ability; on the contrary, if the fast-blow fuse is used in the place where the slow-blow fuse is used, it will often cause the phenomenon that the instant-blow fuse cannot work normally.