China Bolt On Fuse Holder manufacturer
Dongguan Reomax Electronics Technology Co., Ltd
Dongguan Reomax Electronics Technology Co., Ltd
5
Home > Products > Ceramic Tube Fuses >

12A 250V 5x20 Ceramic Fuse Quick Blow Time Lag Fuse With Pins

12A 250V 5x20 Ceramic Fuse Quick Blow Time Lag Fuse With Pins

Brand Name REOMAX
Model Number BFC+P, BTC+P
Certification UL
Place of Origin China
Minimum Order Quantity 2000
Price USD $0.05~$0.1 per piece
Payment Terms T/T
Supply Ability 500K pieces per month
Delivery Time 10 work days
Packaging Details 200pcs per bag, 2000pcs per box, 8000pcs per carton
Item Name Ceramic tube fuse
Blow type fast acting, or slow blow
Mounting Type axial leaded
Standard UL or VDE
Tube material ceramic
Part No. BFC+P, BTC+P
contact material nickel plated brass
Fusing material tinned copper
Voltage Rating 250V
Current Rating 0.1A~20A
Applied to 5x20 5.2x20 tube fuses
UL Listed Yes
RoHS Compliant Yes
Halogen free Yes
MPQ 200pcs per bag
Package 200pcs per bag, 2000pcs per box, 8000pcs per carton
Detailed Product Description

5x20 Ceramic Fuse with Pigtails 5.2x20 Ceramic Body Quick Blow Time-Lag Axial Lead Fuse with pins

Description

ItemCeramic Fuse
StandardUL or VDE
Blow Typefast acting, slow blow
Body Materialglass
Leads Materialtinned copper
Cap Materialnickel plated brass
Voltage Rating250V 125V
Current Rating0.1A~20A
Mounting Typeaxial leaded
Breaking Capacity35A 100A 200A 10KA
Size5.2x20 mm
CertificationsCUL UL VDE CCC
Applicationshome appliance, power supply, telecommunication, consuming electronics

 

Product Features

Operation temperature
-55℃ To +125℃
Warranty Period
2 years
MPQ500PCS
MOQ2000PCS
 

Operating Temperature: -55℃ to +125℃ (Consider de-rating)

Stored condition: at temperature of +10℃~60℃, relative humidity ≤ 75%.

Recommended Soldering Parameters: Soldering pot temperature: 260℃ Max; Solder dwell time: 2∼5s

Resistance to Soldering Heat: 260℃, 10s. (Wave); 350℃, 5s. (Soldering iron)

Solderability: 260℃, ≤ 3s. (Wave); 350±10℃, ≤ 3s. (Soldering iron)

 

Blowing time

 

Fast blow

Time vs Current Characteristics: IEC 60127
Rated current210%275%
Blowing Time<30min10ms~2s
Time vs Current Characteristics:UL248-1/14
Rated current100%200%
Blowing Time>4hs<5s

 

Time delay

Time vs Current Characteristics: IEC 60127
Rated current210%275%
Blowing Time<30min750ms~80s
Time vs Current Characteristics:UL248-1/14
Rated current100%200%
Blowing Time>4hs<5s
 
 

TDS of FBC 5.2x20 glass fuse with pigtails

 

Breaking Capacity UL certified

Amps(A)Volts(V)Interrupting Rating(A)
0.2 - 0.25125Vac10000
0.3 - 2125Vac10000
2.5 - 10125Vac10000
0.2 - 0.25250Vac35
0.3 - 1250Vac35
1.25 - 2250Vac100
2.5 - 3.15250Vac100
4 - 10250Vac200
      

 

Popular Ratings:

Amp

Code

Rated

Current

Rated

Voltage

Voltage

Drop

Max(mV)

Max.Power

Dissipation(W)

Typical Cold

Resistance

(mΩ)

Nominal

Melting

I2t(A2sec)

Breaking

Capacity

Approvals
cURusCQCVDEPSECCC
     
0250250mA


125 V AC
250 V AC
14001.65700.02610KA/125V AC
100A/250V AC
0315315mA13001.68600.109
0400400mA12001.65400.240
0500500mA10001.62200.168
0630630mA6501.62850.723
0800800mA2401.61200.757
11001.00A2001.61011.64
11251.25A2001.665.02.56
11501.50A1901.651.473.76
11601.60A1901.650.354.00
12002.00A1701.640.655.76
12502.50A1701.630.009.61
13003.00A1502.525.0013.9
13153.15A1502.524.0020.7
14004.00A1302.517.6022.1
15005.00A1302.513.5041.0
16306.30A1302.510.6070.6
17007.00A1302.59.48106
18008.00A13047.50164
210010.00A13046.30272
212512.50A10063.80702
216016.00A10063.101332

 

Note: (1) Permissible continuous operating current is 100% at ambient temperature of 23°C (73.4°F)


(2) The cURus certification by 125V and 250V; the VDE certification with 8A~10A by 125V and 250V; the others certification by 250V.

 

(3) The current values used for calculating I2T should be within the standard range of 8ms ~ 10ms.

 

 

Standard Package:

200pcs per bag, 2000pcs per box, 8000pcs per carton

 

Shipping Term:

EXW, DDU, DDP, C&F, FOB

 

Shipping Methods:

International Express, By Air, By Sea

Selection of the Fuse and Holder Solution

The first step is to answer the following questions:

  • Will the fuse need to accessible for replacement?
  • How often will the fuse need to be replaced?
  • Should the end customer of the appliance have access to change the fuse?
  • Should the fuse only be accessible from outside the appliance?
  • How much is available to spend on safety and reliability?

5.1.2. Requirements and characteristics

The most important standards for fuse-holders, which specify requirements, characteristics and testing methods are:

  • IEC-publication 257 (1968) and Amendment no. 2 to this publication dated January 1989.
  • UL-standard no. 512.

 

Test Equipment
  • Company warehouse
FAQ

Q: Are you trading company or manufacturer ?

A: We are a fuse product factory.

Q: How long is your delivery time?

A: Generally it is 3 days if the goods are in stock, 5-10 days if the goods not in stock, according to the quantity.

Q: Do you provide samples ? is it free or extra ?

A: Yes, we could offer the sample for free charge but do not pay the cost of freight.

Q: What is your terms of payment ?

A: 100% in advance, T/T.

Product Tags: 5x20 Ceramic Fuse   12A 250V Ceramic Fuse   20 Amp Ceramic Fuse  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Dongguan Reomax Electronics Technology Co., Ltd
Subject:
Message:
Characters Remaining: (80/3000)