1000mm 304 SS Roof Air Ventilator , Wind Driven Roof Extractor Fan

Brand Name Silver Star
Model Number YXRF-800
Certification ISO9001, SONCAP
Place of Origin China
Minimum Order Quantity 1 Set
Price 10-40USD/ Set
Payment Terms T/T, Western Union, D/A, D/P, L/C
Supply Ability 200000sets/ month
Delivery Time 7-10 working days after advanced payment
Packaging Details Standard exporting packaging
Keywords Non-Power Wind Driven Roof Ventilator Natural Air Exhaust Fans
Other Name Roof mounted exhaust fan
Roof Ventilator Material 304 stainless steel fans
Roof Ventilator Diameter 300/400/500/600/800/900/1000mm
Working Theory Indoor and outdoor air convection
Features Save electricity, reduce noise
Use For Poultry farming equipment or other industries
Assembled On roof
Marketing Type New Product 2021
HS Code 84362900
Detailed Product Description

                   304 Stainless Steel Non-Power Wind Driven Roof Ventilator
                                        Natural Air Exhaust Fans
 
 
Non-Power Wind Driven Roof Ventilator Natural Air Exhaust Fans Description
 
Non-power wind driven roof ventilator natural air exhaust fans use 304 stainless steel materail with a long life service,  with features of zero-cost operating costs, considerable energy efficiency, economical installation costs, and low maintenance costs, which are widely used in poultry chicken farms. Roof ventilator working principle: Turbine ventilators use natural wind and air thermal convection caused by the difference between indoor and outdoor temperature to push the turbine to rotate so as to use centrifugal force and negative pressure to expel the stale indoor hot air.
 
 
Roof Ventilator Natural Air Exhaust Roof Fans Specification
 

ModelDiameter(mm)

Fans Balde Quantity

(pcs)

Height(mm)

Inlet Air

Speed(m/s)

Material
YXRF-400400263903.4304Stainless steel
YXRF-500500324803.4304Stainless steel
YXRF-600600326003.4

304Stainless steel

 

YXRF-800800426603.4304Stainless steel
YXRF-900900487003.4304Stainless stee

 
 
Roof Ventilator Natural Air Exhaust Fans Characteristics:
 
1. High-quality structure:
Rigid spherical structure, permanent lubrication of the upper and lower ball bearings, to ensure a long life and maintenance-free, no need to replace parts, Cases, the American PEER, UBC, Japan NSK high-precision bearing system is fully enclosed and absolutely excellent quality assurance.
2. Operation of precision equipment:
UBC high-precision bearing system is fully enclosed, high heat-resistant synthetic grease lubricant, suitable for permanent self-lubricating, non-lubricating best bearings. Be careful, even if there is a breeze of less than 2 kilometers, it is self-supporting.
3. Green ventilation:
Adopt the principle of natural wind drive, do not use motor power, avoid the cost of non-electric operation, and do not stop the self-turbine ventilator. Rotating, silent and no noise during operation.
4. Wide applicability:
Light steel special-shaped slab roofs of various industrial plants with unique angles in diameter can be installed with concrete roofs. And does not need support, easy to install.

 

 

Maintenance Precautions

 

1. Under normal conditions, if the unpowered fan runs continuously for about one month, it is necessary to inject calcium-sodium-based grease or molybdenum disulfide grease into the bearing with a butter station. The fan runs continuously for 3-6 months, and the grease should be replaced once to fill 2/3 of the bearing space.

2. Regular maintenance of unpowered fans to eliminate dust and dirt inside the fans.

3. During the startup, shutdown or operation of the unpowered fan, if abnormal conditions are found, including temperature, vibration, noise, etc., they should be overhauled immediately.

4. Use the adjusting device to keep the triangle tape evenly tensioned and not too loose or too tight. The length of several triangle tapes should be the same as possible.

5. For unused standby machines or fans that have been out of service for a long time, the rotor should be rotated by 120°-180° regularly to prevent the main shaft from bending. Add a valve to the inlet or outlet of the roof unpowered fan, close it when starting, and open the valve after operation until it reaches the specified working condition, and the inner ring and the shaft fit tightly.

6. In order to ensure personal safety, the maintenance of the roof unpowered fan must be carried out during shutdown

 