16-way switch industrial remote control DH-Z16F, with button text identification: UP, Down, EAST, West, South,
North, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, start, stop, power indicator,
signal indicator;
Main function: Control the equipment to run up, down, east, west, north, and
south in a conventional jog mode, with up and down interlocking,
east-west interlocking, north-south interlocking, 1 and 2
interlocking, 3 and 4 interlocking, 5 and 6 interlocking, 7 and 8
interlocking, 9 and 10 interlocking.
Product highlight: Good anti-interference performance, with unique identification
codes between each remote control transmitter and receiver,
reaching hundreds of millions of sets, never repeating, and
strictly avoiding mutual interference and potential interference.
And the remote control has up to 50-256 frequency points, and each
set in the same environment can be configured with separate
frequency points. Even if the frequency points overlap, given the
uniqueness of the ID identification code, there will be no impact
on each other, ensuring safety and reliability.
Usage: crane, crown block, crane, three hoist crane, three trolley crane,
gantry crane, portal crane, port crane, bridge erecting machine,
beam lifting machine, etc. with main and auxiliary hooks within 16
point switch value, as well as elevator, winch, motor, plate shear,
sand screen, concrete pump, electric flat car, cantilever crane,
industrial furnace door, etc.
Technical parameters: remote control distance of 100 meters, 250 meters, working
temperature of -35 ° -+75 °, transmitter power supply of 3 No. 5
dry batteries of 4.5V, receiver terminal conventional working
voltage of 12-24V AC/DC, other voltages of AC220V or AC380V, etc.,
can be adapted through external transformer voltage conversion.
Model and configuration instructions: This machine model DH-Z16F comes standard with 1 transmitter and 1
receiver. The transmitter antenna is built-in, and the receiver is
equipped with an external extended suction cup antenna (1 meter
long feeder), which is attached to the outside of the distribution
box and installed inside the receiver.