Brand Name VEIKONG
Model Number VFD500
Certification CE
Place of Origin China
Minimum Order Quantity 1
Price Negotiable
Payment Terms Western Union, T/T, L/C, D/A, D/P, PayPal
Supply Ability 15000pcs per Month
Delivery Time 3 days, depend on the order quantity
Packaging Details Carton and Wooden Box
Product Name 11KW 15KW 18.5KW VFD
Voltage 220V, 380V, 440V, 480V
Communication MODBUS
Power Range 0.75KW-710KW
Current Depend on model
Keyboard LED and LCD
Detailed Product Description

11KW 15KW 18.5KW VFD Frequency Drive Inverter With V/F Control

 

Technical Specifications

 

ItemSpecification
InputInput Voltage

1phase/3phase 220V:200V~240V

3 phase 380V-480V:380V~480V

Allowed Voltage fluctuation range-15%~10%
Input frequency50Hz / 60Hz,fluctuation less than 5%
OutputOutput Voltage3phase:0~input voltage
Overload capacity

General purpose application:60S for 150% of the rated current

Light load application:60S for 120% of the rated current

ControlControl mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

Operating modeSpeed control,Torque control(SVC and VC)
Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

Frequency range

0.00~600.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.1%

Startup torque

150%/0.5Hz(V/f)

180%/0.25Hz(SVC)

200%/0Hz(VC)

Torque control accuracy

SVC:within 5Hz10%,above 5Hz5%

VC:3.0%

V/f curve

V / f curve type: straight line, multi point, power function, V / f separation;

Torque boost support: Automatic torque boost (factory setting), manual torque boost

Frequency giving ramp

Support linear and S curve acceleration and deceleration;

4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

DC bus voltage control

Over-voltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;

 

Under-voltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure

 

VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

Vdc Min control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump under-voltage fault

Carrier frequency1kHz~12kHz(Varies depending on the type)
Startup methodDirect start (can be superimposed DC brake); speed tracking start
Stop methodDeceleration stop (can be superimposed DC braking); free to stop
Main control functionJog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN
FunctionKeypadLED Digital keyboard and LCD keypad(option)
Communication

Standard:

MODBUS communication

CAN OPEN AND PROFINET( IN DEVELOPMENT)

PG cardIncremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card
Input terminal

Standard:

5 digital input terminals, one of which supports high-speed pulse input up to 50kHz;

2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input;

Option card:

4 digital input terminals

2 analog input terminals.support-10V-+10V voltage input

Output terminal

standard:

1 digital output terminal;

1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output;

1 relay output terminal(second relay is an option )

2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output;

Option card: 4 digital output terminals

ProtectionRefer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function
EnvironmentInstallation locationIndoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.
Altitude0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m
Ambient temperature-10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C
HumidityLess than 95%RH, without condensing
VibrationLess than 5.9 m/s2 (0.6 g)
Storage temperature-20°C ~ +60°C
OthersInstallationWall-mounted, floor-controlled cabinet, transmural
Protection levelIP20
cooling methodForced air cooling
EMCCE ROHS

Internal EMC filter

Complies with EN61800-3

Category C3

3rd Environment

 

 

Product Application

 

 

 

 

FAQ:

 

1. What voltage range can you support?

 

Single-phase 220v input, single-phase 220v output;
Single-phase 220v input, three-phase 220v output;
Three-phase 220v input, three-phase 220v output;
Single-phase 220v input, three-phase 380v output;

 

2. What is the standard of package?

 

Below 37kw, it's carton package; 45kw and above, it's wooden package.

 

3. Do you accept OEM business?

 

We accept OEM and ODM with your autherization.

Product Tags: MODBUS Communication VFD Frequency Drive Inverter   VF Control VFD Frequency Drive Inverter   0.75KW variable frequency drive inverter  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Shenzhen Veikong Electric Co., Ltd.
Subject:
Message:
Characters Remaining: (80/3000)