China Single Phase Solar Pump Inverter manufacturer
Shenzhen Veikong Electric Co., Ltd.
Shenzhen Veikong Electric Co., Ltd.
4
Home > Products > Variable Frequency Inverters >

Advanced Vector Control Technology in VEIKONG Variable Frequency Inverters

Advanced Vector Control Technology in VEIKONG Variable Frequency Inverters

Brand Name VEIKONG
Model Number VFD500
Certification CE ROHS
Place of Origin China
Minimum Order Quantity 1
Price Negotiable
Payment Terms L/C, T/T, Western Union
Supply Ability 15000pcs per Month
Delivery Time 3 days, depend on the order quantity
Packaging Details the power less than 45kw use Carton, starting from 45kw use Wooden case
Product Name 2.2kw AC drive
Power 2.2kw/3hp
Communication modbus485/profinet/canopen
EMC bulit in EMC C3 filter
Keypad LCD+LED
Color Dark blue and white
Brand VEIKONG
Technical support Online technical support
Warranty period 18 months or more
Communication method RS485 and CANOPEN etc
Detailed Product Description

2.2 Kw Variable Frequency Drive Inverter VFD For Vector Control VF Control

 
VEIKONG  hot selling VFD
 
VFD500M is high performance vector control mini vfd
 
VFD500 is high performacne general vfd
 
VFD550 is high perfromance special vfd with positional control.
 
VFD530 is high performance special vfd with lifting function, support 2 PID, support Synchronous and asynchronous motors
 
VFD500-PV is solar pump inverter.
 
 
 
Drive design & features
VEIKONG continues to make applications even smaller by combining the compact designed drive with
the light, efficient design of a synchronous motor. Use Side-by-Side installation for an even more compact setup.
Finless models available.
 
Independent duct design
Independent air duct design, effectively preventing dust entering inverter, causing short-circuit and other faults and
improving reliability. Use bigger air volume and long life cooling fan effectively reduces the internal temperature rise of the inverter
and ensures reliable and stable operation of inverter
 
 

Features

 

1. VF and Sensorless Vector Control
2. Up to 0Hz/200% starting torque
3. Built-in braking unit (≤30kW), Optional external braking unit (≥37kW)
4. External LED keypad to copy parameters(≥18.5kW), Standard membrane keypad design(≤15kW), Optional LCD keypad provided
5. Standard C3 filters; Optional C2 filters
6. Accurate parameters auto tuning and better motor drive
7. Simple water supply function
8. Support G/P dual rating
9. Customization services provided (like PTC )
10. CE requirements certified

 

 

Techincal Parameters:

 

ItemSpecifiation
InputInuput Voltage

1phase/3phase 220V:200V~240V

3 phase 380V-480V:380V~480V

 Allowed Voltage fluctuation range-15%~10%
 Input frequency50Hz / 60Hz,fluctuation less than 5%
OutputOutput Voltage3phase:0~input voltage
 Overload capacity

General purpose application:60S for 150% of the rated current

Light load application:60S for 120% of the rated current

ControlControl mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

 Operating modeSpeed control,Torque control(SVC and VC)
 Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

 Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

 Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

 frequency range

0.00~600.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

 Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.1%

 Startup torque

150%/0.5Hz(V/f)

180%/0.25Hz(SVC)

200%/0Hz(VC)

 Torque control accuracy

SVC:within 5Hz10%,above 5Hz5%

VC:3.0%

 V/f curve

V / f curve type: straight line, multipoint, power function, V / f separation;

Torque boost support: Automatic torque boost (factory setting), manual torque boost

 Frequency giving ramp

Support linear and S curve acceleration and deceleration;

4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

 DC bus voltage control

Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;

 

Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure

 

VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault

 Carrier frequency1kHz~12kHz(Varies depending on the type)
 Startup methodDirect start (can be superimposed DC brake); speed tracking start
 Stop methodDeceleration stop (can be superimposed DC braking); free to stop
 Maincontrol functionJog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parameters free switching, software swap output wiring, terminals UP / DOWN
FunctionKeypadLED Digital keyboard and LCD keypad(option)
 communication

Standard:

MODBUS communication

Option:Profibus-DP and CAN OPEN

 PG cardIncremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card
 Input terminal

Standard:

5 digital input terminals, one of which supports high-speed pulse input up to 50kHz;

2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input;

Option card:

4 digital input terminals

2 analog input terminals.support-10V-+10V voltage input

 Output terminal

standard:

1 digital output terminal;

1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output;

1 relay output terminal(second relay is an option )

2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output;

Option card: 4 digital output terminals

ProtectionRefer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function
EnvironmentInstallation locationIndoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.
 Altitude0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m
 Ambient temperature-10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C
 HumidityLess than 95%RH, without condensing
 VibrationLess than 5.9 m/s2 (0.6 g)
 Storage temperature-20°C ~ +60°C
OthersInstallationWall-mounted, floor-controlled cabinet, transmural
 Protection levelIP20
 cooling methodForced air cooling

 

 

 

VEIKONG VFD application:

 

 

 

VEIKONG VFD replace famous brands

 

 

Mode Range

Model

Power capacity

(KVA)

Input current

(A)

Output current(A)

Adaptable Motor

(KW)

SIZEBrake Unit
Heavy loadLight load
Three phase: 380-480V,50/60Hz
VFD500-R75GT4B1.53.42.54.20.75SIZE AInternal
VFD500-1R5GT4B354.25.61.5
VFD500-2R2GT4B45.85.69.42.2
VFD500-4R0G/5R5PT4B5.910.59.413.03.7
VFD500-5R5G/7R5PT4B8.914.613.017.05.5SIZE B
VFD500-7R5G/011PT4B1120.517.023.07.5
VFD500-011G/015PT4B1726.025.031.011SIZE CInternal
VFD500-015G/018PT4B2135.032.037.015
VFD500-018G/022PT4B2438.537.045.018.5SIZE D
VFD500-022G/030PT4B3046.545.057.022
VFD500-030G/037PT44062.060.075.030SIZE Eoption
VFD500-037G/045PT45076.075.087.037
VFD500-045G/055PT46092.090.0110.045SIZE F
VFD500-055G/075PT475113.0110.0135.055
VFD500-075G/090PT4104157.0152.0165.075SIZE G
VFD500-090G/110PT4112170.0176.0210.090External
VFD500-110G/132PT4145220.0210.0253.0110SIZE H
VFD500-132G/160PT4170258.0253.0304.0132SIZE I
VFD500-160G/185PT4210320.0304.0360.0160
VFD500-185G/200PT4245372.0360.0380.0185SIZE J
VFD500-200G/220PT4250380.0380.0426.0200
VFD500-220G/250PT4280425.0426.0465.0220SIZE K
VFD500-250G/280PT4315479.0465.0520.0250
VFD500-280G/315PT4350532.0520.0585.0280SIZE L
VFD500-315G/355PT4385585.0585.0650.0315
VFD500-355G/400PT4420638.0650.0725.0355SIZE M
VFD500-400G/450PT4470714.0725.0820.0400
VFD500-450G/500PT4530800.0820.0/450SIZE N
VFD500-500G/560PT4580880.0900.0/500
VFD500-560G/630PT4630950.0980.0/560SIZE O
VFD500-630GT471010801120./630SIZE O
VFD500-710GT479012001260/710SIZE O
Single phase :220V ,50/60HZ
VFD500-R40GS21.36.03.25.60.4SIZE AInbuilt
VFD500-R75GS22.411.05.68.00.75SIZE A
VFD500-1R5GS23.515.08.010.61.5SIZE A
VFD500-2R2GS25.525.010.614.02.2SIZE A
VFD500-4R0GS27.735.017.023.04.0SIZE B
VFD500-5R5GS28.953.025.031.05.5SIZE C
VFD500-7R5GS21167.032.037.07.5SIZE C
 

 


 


 
 
 
 
Product Tags: 2.2 Kw Variable Frequency Inverters   CE Variable Frequency Inverters   Vector Control 2.2 Kw Vfd  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Shenzhen Veikong Electric Co., Ltd.
Subject:
Message:
Characters Remaining: (80/3000)