China Single Phase Solar Pump Inverter manufacturer
Shenzhen Veikong Electric Co., Ltd.
Shenzhen Veikong Electric Co., Ltd.
4
Home > Products > VFD Variable Frequency Drive >

0.75kw-710kw Single 3 Phase VFD Controller For Extruder Machine

0.75kw-710kw Single 3 Phase VFD Controller For Extruder Machine

Brand Name VEIKONG
Model Number VFD500
Certification CE, ROHS
Place of Origin CHINA
Minimum Order Quantity 1
Price Please contact quotation
Payment Terms T/T, Western Union, L/C
Supply Ability 1000 units per week
Delivery Time depends on quantities
Packaging Details <45kw inverter be used carton package, ≥45kw be used wood case package
Product name VFD
Power 0.75kw-710kw
Current 2.5A-950A
Frequency 0-2000HZ
Protection Overload,Overvoltage,IP20,Short Circuit,over heat
Igbt Infineon
Detailed Product Description

Variable frequency drive 0.75kw-710kw VFD single three phase

 

Product Advantage

 

VFD500 Excellent control performance

 

 0.1s command acceleration and deceleration under rated load of motor

 

 When the motor is switching over zero speed, there is no phase change and oscillation in the current, and the speed is not pulsating.

 

 Bus voltage control is stable, deceleration without dynamic braking can also provide fast and reliable braking capability

 

 Realize no tripping operation

 

 Excellent current and voltage control technology, alternately accelerating and decelerating with 0.1s command, the inverter is stable without tripping operation

 

 Strong overload capacity, continuous operation for 10s under 180% rated load condition, 1 minute continuous operation under 150% rated load condition

 

 Low frequency and high torque stable operation under vector control

 

 Unique power grid instantaneous power-down processing

 

 

VFD500 technical data:
 
ItemSpecifiation
InputInuput Voltage

1phase/3phase 220V:200V~240V

3 phase 380V-480V:380V~480V

 Allowed Voltage fluctuation range-15%~10%
 Input frequency50Hz / 60Hz,fluctuation less than 5%
OutputOutput Voltage3phase:0~input voltage
 Overload capacity

General purpose application:60S for 150% of the rated current

Light load application:60S for 120% of the rated current

ControlControl mode

V/f control

Sensorless flux vector control without PG card(SVC)

Sensor speed flux vector control with PG card (VC)

 Operating modeSpeed control,Torque control(SVC and VC)
 Speed range

1:100 (V/f)

1:200( SVC)

1:1000 (VC)

 Speed control accuracy

±0.5% (V/f)

±0.2% (SVC)

±0.02% (VC)

 Speed response

5Hz(V/f)

20Hz(SVC)

50Hz(VC)

 frequency range

0.00~600.00Hz(V/f)

0.00~200.00Hz(SVC)

0.00~400.00Hz(VC)

 Input frequency resolution

Digital setting: 0.01 Hz

Analog setting: maximum frequency x 0.1%

 Startup torque

150%/0.5Hz(V/f)

180%/0.25Hz(SVC)

200%/0Hz(VC)

 Torque control accuracy

SVC:within 5Hz10%,above 5Hz5%

VC:3.0%

 V/f curve

V / f curve type: straight line, multipoint, power function, V / f separation;

Torque boost support: Automatic torque boost (factory setting), manual torque boost

 Frequency giving ramp

Support linear and S curve acceleration and deceleration;

4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s

 DC bus voltage control

Overvoltage stall control: limit the power generation of the motor by adjusting the output frequency to avoid skipping the voltage fault;

 

Undervoltage stall control: control the power consumption of the motor by adjusting the output frequency to avoid yaw failure

 

VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip;

VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault

 Carrier frequency1kHz~12kHz(Varies depending on the type)
 Startup method

Direct start (can be superimposed DC brake); speed tracking start

 Stop methodDeceleration stop (can be superimposed DC braking); free to stop
Maincontrol functionJog control, droop control, up to 16-speed operation, dangerous speed avoidance, swing frequency operation, acceleration and deceleration time switching, VF separation, over excitation braking, process PID control, sleep and wake-up function, built-in simple PLC logic, virtual Input and output terminals, built-in delay unit, built-in comparison unit and logic unit, parameter backup and recovery, perfect fault record,fault reset, two groups of motor parametersfreeswitching, software swap output wiring, terminals UP / DOWN
FunctionKeypadLED Digital keyboard and LCD keypad(option)
Communication

Standard:

MODBUS communication

CAN OPEN AND PROFINET( IN DEVELOPMENT)

PG cardIncremental Encoder Interface Card (Differential Output and Open Collector), Rotary transformer Card
Input terminal

Standard:

5 digital input terminals, one of which supports high-speed pulse input up to 50kHz;

2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA current input;

Option card:

4 digital input terminals

2 analog input terminals.support-10V-+10V voltage input

Output terminal

standard:

1 digital output terminal;

1 high-speed pulse output terminal (open collector type), support 0 ~ 50kHz square wave signal output;

1 relay output terminal(second relay is an option )

2 analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output;

Option card: 4 digital output terminals

ProtectionRefer to Chapter 6 "Troubleshooting and Countermeasures" for the protection function
EnvironmentInstallation locationIndoor, no direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.
Altitude0-3000m.inverter will be derated if altitude higher than1000m and rated output current will reduce by 1% if altitude increase by 100m
Ambient temperature-10°C~ +40°C,maximum 50°C (derated if the ambient temperature is between 40°C and 50°C)Rated output current decrease by 1.5% if temperature increase by 1°C
HumidityLess than 95%RH, without condensing
VibrationLess than 5.9 m/s2 (0.6 g)
Storage temperature-20°C ~ +60°C
OthersInstallationWall-mounted, floor-controlled cabinet, transmural
Protection levelIP20
cooling methodForced air cooling
EMCCE ROHS

Internal EMC filter

Complies with EN61800-3

Category C3

3rd Environment

 

Replace famous brands vfd in general application.

 

 

VFD500 parameter distribution list:

ClassificationParameter groupPage
Common parameters00:Basic functionPage 37
01:Frequency source selectionPage 39
02:Start and stopPage 45
03:Ramp and S curvePage 49
04: Analog and pulse inputPage 51
05:Analog and pulse outputPage 55
06:Multi-function Digital input (DI)Page 56
07: Multi-function Digital output(DO)Page 59
08:Digital Output settingPage 62
Motor control10:Encoder typePage 65
11:Motor1 parmeterPage 66
12:Motor1 VFcontrol parameterPage 68
13:Motor1 Vector controlparameterPage 71
14:Torque controlPage 73
16:Energy saving controlPage 74
Display and protection20:User-defined parametersPage 75
21:Keypad and displayPage 77
22:AC Drive configurationPage 79
23:Drive protection function settingPage 81
24:Motor protection parameterPage 85
25:Fault tracking parameterPage 87
26:Fault recording parameterPage 87
27:Monitoring parameterPage 90
Communication30:Modbus communicationPage 90
 31:Canopen communicationPage 92
Application40:Process PID FunctionPage 92
41:Sleep functionPage 98
42:Simple PLCPage 100
43:Programmable delay unitPage 102
44:Comparator and logic unit/controllerPage 104
45:Multifunction counterPage 108
Motor 260:Motor2 basic parameterPage 110
61:Motor2 parameterPage 111
62:Motor2 VF control parameterPage 111
63:Motor2 vector control parameterPage 111

 
Product Tags: 710kw 3 Phase VFD Controller   0.75kw 3 Phase VFD Controller   710kw single phase vfd controller  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Shenzhen Veikong Electric Co., Ltd.
Subject:
Message:
Characters Remaining: (80/3000)