VFD 90kw 120hp Variable Frequency Drive for big torque application Feature of VFD Variable Frequency Drive 1. SFVC /CLVC /VF 2. High Start Torque 3. Fast Dynamic 4. High Frequency & Torque stability 5. Flexible 6. Cost-effective Our Advantages 1. A high-tech giant owning 16 subsidiaries, 2 production bases and
over 3000 employees 2. 12 major R&D centers,17 years of Technology R&D and
patents number reaching over 850 3. Established more than 30 domestic offices and warranty centers
and 8 overseas branches 4. Products sold to more than 60 countries and regions 5. 400 call center provides customers with around-the-clock
technical consulting and repair service. 6. Provide professional products and industrial solutions Item | Specifiation | Input | Inuput Voltage | 1phase/3phase 220V:200V~240V 3 phase 380V-480V:380V~480V | | Allowed Voltage fluctuation range | -15%~10% | | Input frequency | 50Hz / 60Hz,fluctuation less than 5% | Output | Output Voltage | 3phase:0~input voltage | | Overload capacity | General purpose application:60S for 150% of the rated current Light load application:60S for 120% of the rated current | Control | Control mode | V/f control Sensorless flux vector control without PG card(SVC) Sensor speed flux vector control with PG card (VC) | | Operating mode | Speed control,Torque control(SVC and VC) | | Speed range | 1:100 (V/f) 1:200( SVC) 1:1000 (VC) | | Speed control accuracy | ±0.5% (V/f) ±0.2% (SVC) ±0.02% (VC) | | Speed response | 5Hz(V/f) 20Hz(SVC) 50Hz(VC) | | frequency range | 0.00~600.00Hz(V/f) 0.00~200.00Hz(SVC) 0.00~400.00Hz(VC) | | Input frequency resolution | Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.1% | | Startup torque | 150%/0.5Hz(V/f) 180%/0.25Hz(SVC) 200%/0Hz(VC) | | Torque control accuracy | SVC:within 5Hz10%,above 5Hz5% VC:3.0% | | V/f curve | V / f curve type: straight line, multipoint, power function, V / f
separation; Torque boost support: Automatic torque boost (factory setting),
manual torque boost | | Frequency giving ramp | Support linear and S curve acceleration and deceleration; 4 groups of acceleration and deceleration time, setting range 0.00s
~ 60000s | | DC bus voltage control | Overvoltage stall control: limit the power generation of the motor
by adjusting the output frequency to avoid skipping the voltage
fault; Undervoltage stall control: control the power consumption of the
motor by adjusting the output frequency to avoid yaw failure VdcMax Control: Limit the amount of power generated by the motor by
adjusting the output frequency to avoid over-voltage trip; VdcMin control: Control the power consumption of the motor by
adjusting the output frequency, to avoid jump undervoltage fault | | Carrier frequency | 1kHz~12kHz(Varies depending on the type) | | Startup method | Direct start (can be superimposed DC brake); speed tracking start |
| Stop method | Deceleration stop (can be superimposed DC braking); free to stop | Maincontrol function | Jog control, droop control, up to 16-speed operation, dangerous
speed avoidance, swing frequency operation, acceleration and
deceleration time switching, VF separation, over excitation
braking, process PID control, sleep and wake-up function, built-in
simple PLC logic, virtual Input and output terminals, built-in
delay unit, built-in comparison unit and logic unit, parameter
backup and recovery, perfect fault record,fault reset, two groups
of motor parametersfreeswitching, software swap output wiring,
terminals UP / DOWN | Function | Keypad | LED Digital keyboard and LCD keypad(option) | Communication | Standard: MODBUS communication CAN OPEN AND PROFINET( IN DEVELOPMENT) | PG card | Incremental Encoder Interface Card (Differential Output and Open
Collector), Rotary transformer Card | Input terminal | Standard: 5 digital input terminals, one of which supports high-speed pulse
input up to 50kHz; 2 analog input terminals, support 0 ~ 10V voltage input or 0 ~ 20mA
current input; Option card: 4 digital input terminals 2 analog input terminals.support-10V-+10V voltage input | Output terminal | standard: 1 digital output terminal; 1 high-speed pulse output terminal (open collector type), support 0
~ 50kHz square wave signal output; 1 relay output terminal(second relay is an option ) 2 analog output terminals, support 0 ~ 20mA current output or 0 ~
10V voltage output; Option card: 4 digital output terminals | Protection | Refer to Chapter 6 "Troubleshooting and Countermeasures" for the
protection function | Environment | Installation location | Indoor, no direct sunlight, dust, corrosive gas, combustible gas,
oil smoke, vapor, drip or salt. | Altitude | 0-3000m.inverter will be derated if altitude higher than1000m and
rated output current will reduce by 1% if altitude increase by 100m | Ambient temperature | -10°C~ +40°C,maximum 50°C (derated if the ambient temperature is
between 40°C and 50°C)Rated output current decrease by 1.5% if
temperature increase by 1°C | Humidity | Less than 95%RH, without condensing | Vibration | Less than 5.9 m/s2 (0.6 g) | Storage temperature | -20°C ~ +60°C | Others | Installation | Wall-mounted, floor-controlled cabinet, transmural | Protection level | IP20 | cooling method | Forced air cooling | EMC | CE ROHS | Internal EMC filter Complies with EN61800-3 Category C3 3rd Environment |
Replace famous brands vfd in general application.
Model Range Model | Power capacity (KVA) | Input current (A) | Output current(A) | Adaptable Motor (KW) | SIZE | Brake Unit | Heavy load | Light load | Three phase: 380-480V,50/60Hz | VFD500-R75GT4B | 1.5 | 3.4 | 2.5 | 4.2 | 0.75 | SIZE A | Internal | VFD500-1R5GT4B | 3 | 5 | 4.2 | 5.6 | 1.5 | VFD500-2R2GT4B | 4 | 5.8 | 5.6 | 9.4 | 2.2 | VFD500-4R0G/5R5PT4B | 5.9 | 10.5 | 9.4 | 13.0 | 3.7 | VFD500-5R5G/7R5PT4B | 8.9 | 14.6 | 13.0 | 17.0 | 5.5 | SIZE B | VFD500-7R5G/011PT4B | 11 | 20.5 | 17.0 | 23.0 | 7.5 | VFD500-011G/015PT4B | 17 | 26.0 | 25.0 | 31.0 | 11 | SIZE C | Internal | VFD500-015G/018PT4B | 21 | 35.0 | 32.0 | 37.0 | 15 | VFD500-018G/022PT4B | 24 | 38.5 | 37.0 | 45.0 | 18.5 | SIZE D | VFD500-022G/030PT4B | 30 | 46.5 | 45.0 | 57.0 | 22 | VFD500-030G/037PT4 | 40 | 62.0 | 60.0 | 75.0 | 30 | SIZE E | option | VFD500-037G/045PT4 | 50 | 76.0 | 75.0 | 87.0 | 37 | VFD500-045G/055PT4 | 60 | 92.0 | 90.0 | 110.0 | 45 | SIZE F | VFD500-055G/075PT4 | 75 | 113.0 | 110.0 | 135.0 | 55 | VFD500-075G/090PT4 | 104 | 157.0 | 152.0 | 165.0 | 75 | SIZE G | VFD500-090G/110PT4 | 112 | 170.0 | 176.0 | 210.0 | 90 | External | VFD500-110G/132PT4 | 145 | 220.0 | 210.0 | 253.0 | 110 | SIZE H | VFD500-132G/160PT4 | 170 | 258.0 | 253.0 | 304.0 | 132 | SIZE I | VFD500-160G/185PT4 | 210 | 320.0 | 304.0 | 360.0 | 160 | VFD500-185G/200PT4 | 245 | 372.0 | 360.0 | 380.0 | 185 | SIZE J | VFD500-200G/220PT4 | 250 | 380.0 | 380.0 | 426.0 | 200 | VFD500-220G/250PT4 | 280 | 425.0 | 426.0 | 465.0 | 220 | SIZE K | VFD500-250G/280PT4 | 315 | 479.0 | 465.0 | 520.0 | 250 | VFD500-280G/315PT4 | 350 | 532.0 | 520.0 | 585.0 | 280 | SIZE L | VFD500-315G/355PT4 | 385 | 585.0 | 585.0 | 650.0 | 315 | VFD500-355G/400PT4 | 420 | 638.0 | 650.0 | 725.0 | 355 | SIZE M | VFD500-400G/450PT4 | 470 | 714.0 | 725.0 | 820.0 | 400 | VFD500-450G/500PT4 | 530 | 800.0 | 820.0 | / | 450 | SIZE N | VFD500-500G/560PT4 | 580 | 880.0 | 900.0 | / | 500 | VFD500-560G/630PT4 | 630 | 950.0 | 980.0 | / | 560 | SIZE O | VFD500-630GT4 | 710 | 1080 | 1120. | / | 630 | SIZE O | VFD500-710GT4 | 790 | 1200 | 1260 | / | 710 | SIZE O | Single phase: 220V, 50/60HZ | VFD500-R40GS2 | 1.3 | 6.0 | 3.2 | 5.6 | 0.4 | SIZE A | Inbuilt | VFD500-R75GS2 | 2.4 | 11.0 | 5.6 | 8.0 | 0.75 | SIZE A | VFD500-1R5GS2 | 3.5 | 15.0 | 8.0 | 10.6 | 1.5 | SIZE A | VFD500-2R2GS2 | 5.5 | 25.0 | 10.6 | 14.0 | 2.2 | SIZE A | VFD500-4R0GS2 | 7.7 | 35.0 | 17.0 | 23.0 | 4.0 | SIZE B | VFD500-5R5GS2 | 8.9 | 53.0 | 25.0 | 31.0 | 5.5 | SIZE C | VFD500-7R5GS2 | 11 | 67.0 | 32.0 | 37.0 | 7.5 | SIZE C |
|