1.8m Height Early Discharge Lightning Rod , ESE Lightning Conductor Active
|
Detailed Product Description
Hot Sale Stainless Steel Lightning Rod French Original ESE6000 Lightning Rod Outdoor Discharge physics
Discharge physics shows that conventional Franklin lightning rods require a delay time to produce upward gravitational force, and this delay time can limit the effectiveness of vertical or horizontal lightning rods.
Introduction of products This excitation device integrated in the air terminal is designed
to increase the excitation distance and thus generate the ascending tracer earlier(regarding to an ascending tracer naturally emitted by a simple rod. All of our early streamer emission systems are tested in compliance with NF C 17-102 standard,edition September 2011.
Specification Installation Guidelines These 3 main parts are the components of the lightning protection
system. This conductor will usually run outside the structure.Each fixing
should allow an eventual conductor dilatation.Bend radius have to
be inferior to 0.2 meters.Metalli-cal masses situated in the zone
of separation calculated beforehand will be interconnected
equipotentially to the lightning conductor.Each down conductor will
be equipped at the bottom with a control junction and a 2
meter-high mechanical protective tube. The capturing device with its supporting mast and fixings. .The
down conductor composed of one or several tin-ned copper tape with
section in compliance with stan-dards in force,designed to flow the
lightning current of the lightning conductor to the earthing
system. The earthing system with an adapted form in com-pliance with
standards in force has for aim to diffuse the lightning current to
the ground.An inspection pit will be installed to do the
equipotential connection with the nearest electrical earth netword
of the building. Installation quality of a lightning system is an
impor-tant element ofr the efficiency of a lightning protection
system. For each installation and in most of cases it will be
bet-ter to start with the installation of the earthing
sys-tems,then as direct as possible channels of each down
conductor,then finish with the lightning conductor and roof circuit
installation. |
Product Tags: 1.8m discharge lightning rod ESE discharge lightning rod Active ese lightning conductor |
Related Products
![]() |
32700 LiFePO4 Lithium Ion Battery With PCM ProtectionStainless Steel ESE Early Streamer Emission System ISO9001 |
![]() |
ISO9001 SUS 304 Lightning Ground Rod , Active Lightning Rod for High Building |
![]() |
200KA Stainless Steel Lightning Rod Conductor Customizable Length |
![]() |
Protective 304 Stainless Steel Lightning Rod Thunder Arrester ISO9001:2008 |
![]() |
ESE Early Discharge Stainless Steel Lightning Rod OEM ODM Service |
![]() |
OEM Service Silver Lightning Protection Pole 304 Stainless Steel |
Email to this supplier