China Auto Parts Test Equipment manufacturer
HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
6
Home > Products > Flammability Testing Equipment >

IEC 60332 Flammability Testing Equipment For Vertical Flame Propagation Single Insulated Cable

IEC 60332 Flammability Testing Equipment For Vertical Flame Propagation Single Insulated Cable

Brand Name HJ
Model Number VF-1
Certification Calibration Certificate(cost additional)
Place of Origin China
Minimum Order Quantity 1 set
Price Negotiatable
Payment Terms T/T, L/C
Supply Ability 15 set per month
Delivery Time 30 days
Packaging Details Plywood
copper block 9mm in diameter, 10 ± 0 .05g before drilling
Temperature rise time from 100±5°C to 700°±3°C shall be 45±5s
Product name Flammability Test Chamber
Standard IEC 60332
Function Single Cable Burning Test
Metallic screen H*W*D-1200*300*450
distance of upper and lower support 550 ± 5 mm
Gas pressure 650±30mL/min propane; 10±0.5L/min air
Detailed Product Description

Flammability Testing Equipment For Vertical Flame Propagation For Single Insulated Cable

 

Standard:

IEC 60332-1-1 Tests on electric and optical fibre cables under fire conditions –Part 1-1: Test for vertical flame propagation for a single insulated wire or cable – Apparatus;

IEC 60332-1-2 Tests on electric and optical fibre cables under fire conditions –Part 1-2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame;

IEC 60332-1-3 Tests on electric and optical fibre cables under fire conditions –Part 1-3: Test for vertical flame propagation for a single insulated wire or cable – Procedure for determination of flaming droplets/particles.

 

Application:

It is use for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. Flammability Testing Equipment

 

Positioning of test piece:

The test piece shall straightened and be secured to two horizontal supports by means of a suitable size of copper wire, in a vertical position in the centre of the metal screen, as described in 4.2 of IEC 60332-1 -1 , so that the distance between the bottom of the upper

support and the top of the lower support is (550 ± 5) mm. In addition, the test piece shall be positioned so that the bottom of the specimen is approximately 50 mm from the base of the screen (see Figure 1).

The vertical axis of the test piece shall be arranged centrally within the screen (i.e. 150 mm from each side and 225 mm from the rear).

 

Parameter:

Working voltage220V/50Hz
Control operation modeElectrical control, button operation
Burner standardIEC60695-11-2 Annex A, Burner opening:Φ7±0.05mm, made of brass
Gas flow and gas categoryMixture gas: 650±30mL/min propane; 10±0.5L/min air, Dual flow meter adjustment
Burning time9999S. Flammability Testing Equipment
Burning angleTilt 45°±2°, Adjustable
Test flame calibrationTemperature measuring copper block: Ф9mm±0.01mm, weight before drilling:10 ± 0 .05g
Thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100°
Distance between the burner port to temperature measuring copper block: 95 mm
Flame height: Inner flame:55±5mm, Outer flame:180±10mm
The time for the temperature of the copper block, to increase from 100±5°C to 700°±3°C shall be 45±5s
Metallic screen(1 200 ± 25) mm high, (300 ± 25) mm wide and (450 ± 25) mm deep with open front and closed top and bottom
Gas>95% propane or coal gas
Test sampleLength: 600±25mm
Fixed horizontal support of the sample2, distance:550mm

 

 

Product Tags: IEC 60332 Flammability Testing Equipment   9999S Flammability Testing Equipment   Vertical Flammability Testing Equipment  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Subject:
Message:
Characters Remaining: (80/3000)