China Auto Parts Test Equipment manufacturer
HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
7
Home > Products > Leak Testing Equipment >

270pcs/Hour Vacuum Chamber Leak Test For Air Conditioning Condenser

270pcs/Hour Vacuum Chamber Leak Test For Air Conditioning Condenser

Brand Name HeJin
Certification Third party calibration certificate(cost additional)
Place of Origin China
Minimum Order Quantity 1 Set
Price Negotiatable
Payment Terms T/T, L/C
Supply Ability 3 set per 3 month
Delivery Time 90 days
Packaging Details Plywood
test sample Air conditioning condenser / evaporator
Vacuum Chamber qty 3
leak test gas helium
control mode PLC control
detection method vacuum chamber method
Gas Pressure for Fine Leak Test 1.5Mpa
Gas Pressure for Gross Leak Test 2.5 Mpa
detectable leak rate 2g/Year
function Helium Leak Test system for Air conditioning condenser / evaporator
Production capacity 270 pcs/hour
Detailed Product Description

Leak Testing Equipment For Air-Conditioning Condenser / Evaporator Vacuum Chamber Method

 

product information:

The vacuum chamber helium leak detection system has three vacuum chambers, and three vacuum chambers work linked. The operator puts the parts into the vacuum chamber and connects them with the quick joints, and then simultaneously presses the two green buttons on the upper edge of the vacuum chamber. The chamber door is closed and the detection cycle begins automatically. Grating protectors are installed on both sides of the vacuum chamber door, and when the door is closed, it is ensured that there is no object in the door area that interferes with the movement of the door. Once one of the doors is closed, the detection cycle in this chamber begins. Leak Testing Equipment

 

Parameter: (can be customized according to client's requirements)

Workpiece

Air conditioning condenser / evaporator

Vacuum chamber sizeL1250mmX W480mmX D300mm
Vacuum chambers3 pieces (2 pieces per chamber)
Fixture6 sets. Leak Testing Equipment
Gas for gross leak detection2.5 Mpa (downward adjustable)
Tracer gasHelium
Reject point2g/year
Tracer gas pressure2.5 Mpa (downward adjustable)
Production capacity270 pcs/hour
Helium recoveryRecovery rate ≥95%
Vacuuming time50s
Helium filling and detection time10s
Helium recovery time8s
Workpiece loading and unloadingManual

 

System Configuration:

No.ItemBrand
1Chamber and fixtureHJ
2Chamber door and auto- closing mechanismHJ
3Helium-filled and recovery connectorHJ
4Vacuum pumpBAOSI
5Vacuum gaugeAgilent
6Leak detectorAgilent
7Pressure sensorJUMO etc.
8Electromagnetic valveAIRTAC, SMC etc.
9High pressure valveGSR, ASCO etc.
10Standard leakHJ
11Helium boosting systemHJ
12PLCOMRON
13Touch screenWeinview
14Electrical partsFUJI, Schneider etc.
15Pipes and fittingsMade in china
16Helium concentration detectorHJ

 

Product Tags: 270pcs/Hour Vacuum Chamber Leak Test   270pcs/Hour Vacuum Chamber   270pcs/Hour Leak Test For Air Conditioning  