Aluminum Quadruplex Overhead Service Drop Cable Cross-Linked
Polyethylene used to provide three-phase power, typically from a transformer
installed atop a pole to the user's service head, which is
connected to the service entry wire. Use at phase-to-phase voltages
of no more than 600 volts and conductor temperatures not to exceed
75 °C for polyethylene-insulated conductors or 90 °C for conductors
insulated with crosslinked polyethylene (XLP).
h.Model and Name
China Type | Description | Application | Cu | Al | YJV | YJLV | XLPE insulation PVC sheath power cable (Cu/XLPE/PVC) | To be laid indoors, in tunnel, cable furrow or pipe, the cable
couldn't bear mechanical force outside | YJY | YJLY | XLPE insulation PE sheath power cable (Cu/XLPE/PE) | YJV22 | YJLV22 | XLPE insulation, steel tape armor, PVC sheath power cable (Cu/XLPE/PVC/STA/PVC) | To be laid underground, the cable could bear certain mechanical
force, but it couldn't bear great pulling force. | YJV23 | YJLV23 | XLPE insulation, steel tape armor, PE sheath power cable (Cu/XLPE/PVC/STA/PE) | YJV62 | YJLV62 | XLPE insulation, no magnetism steel tape armor, PE sheath power
cable | YJV32 | YJLV32 | XLPE insulation, thin steel-wire armor, PVC sheath power cable (Cu/XLPE/PVC/SWA/PVC) | Be applicable to the well, water inside and fall in the bad soil,
the cable cans bear the equal dint outside the machine with pull
the dint . | YJV72 | YJLV72 | XLPE insulation, have no the magnetism thick steel-wire armor, PVC
sheath power cable | YJV42 | YJLV42 | XLPE insulation, thick steel-wire armor, PVC sheath power cable | Be applicable to the well, underwater with the bottom of sea, the
cable cans bear the bigger pressure with lead to pull the dint. |
Type | Description | Application | Cu Core | Al Core | YJV ZR-YJV | YJLV ZR-YJLV | Cu(Al)Core, XLPE Insulated, PVC Sheathed Power Cable Cu(Al)Core, XLPE Insulated, PVC Sheathed flame- retardant Power
Cable | Can be laid in indoor, outdoor, tunnels, cable channels, reinforced
concrete pipelines and loose soil. Cable should not bear outer
mechanic force, but can bear a certain tractional force. | YJV22 ZR-YJV22 | YJLV22 ZR-YJLV22 | Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed
Power Cable Cu(Al)Core, XLPE Insulated, Steel Tape Armored and PVC Sheathed
flame- retardant Power Cable | Laid underground. Cable can bear outer mechanic force, but should
not bear large tractional force. | YJV32 ZR-YJV32 | YJLV32 ZR-YJLV32 | Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed
Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed
flame- retardant Power Cable | Laid in indoor, tunnels and mines. Cable can bear outer mechanic
force and fairly large tractional force. | YJV42 ZR-YJV42 | YJLV42 ZR-YJLV42 | Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed
Power Cable Cu(Al)Core, XLPE Insulated, Steel Wire Armored and PVC Sheathed
flame- retardant Power Cable | Can be laid in vertical section, indoor, tunnels and mines. Cable
can bear outer mechanic force and very large tractional force. |
|