|
0.6/1kv overhead voltage power cable Overhead abc cables are mainly used for 600V overhead auxiliary power distribution lines. It is not an electrically insulated conductor and is usually regarded as a bare conductor during installation. The conductor is 1350-H19 aluminum wire, 6201-T81 aluminum alloy or ACSR conductor, concentric stranded wire and polyethylene, high density polyethylene (HDPE) or cross-linked Covered with polyethylene (XLPE) to protect against wind and rain.  | | | | | | | | AWG or kcmi | Carrying wire core(acsr) | Phase conductor | insulation | | | Stell | Aluminium | | xlpe | | | No. | Dia. | No. | Dia | Dia | No. | Dia | Dia | | | 3*6AWG+1*6AWG | 1 | 1.68 | 6 | 1.68 | 5.04 | 1 | 4.11 | 4.11 | 1.14 | | 3*6AWG+1*6AWG | 1 | 1.68 | 6 | 1.68 | 5.04 | 7 | 1.55 | 1.55 | 1.14 | | 3*4AWG+1*4AWG | 1 | 2.12 | 6 | 2.12 | 6.36 | 1 | 5.19 | 5.19 | 1.14 | | 3*4AWG+1*4AWG | 1 | 2.12 | 6 | 2.12 | 6.36 | 7 | 1.96 | 5.88 | 1.14 | | 3*2AWG+1*2AWG | 1 | 2.67 | 6 | 2.67 | 8.02 | 7 | 2.47 | 7.42 | 1.14 | | 3*1/0AWG+1*1/0AWG | 1 | 3.37 | 6 | 3.37 | 10.11 | 19 | 1.89 | 9.47 | 1.52 | | 3*2/0AWG+1*2/0AWG | 1 | 3.78 | 6 | 3.78 | 11.35 | 19 | 2.13 | 10.63 | 1.52 | | 3*3/0AWG+1*3/0AWG | 1 | 4.25 | 6 | 4.25 | 12.74 | 19 | 2.39 | 11.94 | 1.52 | | 3*4/0AWG+1*4/0AWG | 1 | 4.77 | 6 | 4.77 | 14.31 | 19 | 2.68 | 13.4 | 1.52 | | 3*336.4+1*336.4 | 1 | 3.47 | 18 | 3.47 | 17.36 | 19 | 3.38 | 16.9 | 2.03 | | 3*336.4+1*4/0AWG | 1 | 4.77 | 6 | 4.77 | 14.31 | 19 | 3.38 | 16.9 | 2.03 | *Applications: To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volt or lower at a conductor temperature of 75℃ maximum. | | | | | | | | | | | | | | | | | | | 1*6AWG+1*6AWG | 7 | 1.56 | 563 | 1 | 4.11 | 1.14 | 92 | 85 | 70 | | 1*6AWG+1*6AWG | 7 | 1.56 | 563 | 7 | 1.56 | 1.14 | 94 | 85 | 70 | | 1*4AWG+1*4AWG | 7 | 1.96 | 881 | 1 | 5.19 | 1.14 | 139 | 115 | 90 | | 1*4AWG+1*4AWG | 7 | 1.96 | 881 | 7 | 1.96 | 1.14 | 141 | 115 | 90 | | 1*2AWG+1*2AWG | 7 | 2.47 | 1350 | 7 | 2.47 | 1.14 | 216 | 150 | 120 | | 1*1/0AWG+1*1/0AWG | 7 | 3.12 | 1990 | 19 | 1.89 | 1.52 | 347 | 205 | 160 | *Applications: To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of75℃ maximum for polyethylene insulation or 90℃ maximum for crosslinked insulation. | | | | | | | | | | | | | | | Dia.mm | | | | 2*6AWG+1*6AWG | 7 | 1.56 | 563 | 1 | 4.11 | 1.14 | 146 | 85 | 70 | | 2*6AWG+1*6AWG | 7 | 1.56 | 563 | 7 | 1.56 | 1.14 | 150 | 85 | 70 | | 2*4AWG+1*4AWG | 7 | 1.96 | 881 | 1 | 5.19 | 1.14 | 219 | 115 | 90 | | 2*4AWG+1*4AWG | 7 | 1.96 | 881 | 7 | 1.96 | 1.14 | 224 | 115 | 90 | | 2*2AWG+1*2AWG | 7 | 2.47 | 1350 | 7 | 2.47 | 1.14 | 338 | 150 | 120 | | 2*1/0AWG+1*1/0AWG | 7 | 3.12 | 1990 | 7 | 3.12 | 1.52 | 544 | 205 | 160 | | 2*1/0AWG+1*1/0AWG | 7 | 3.12 | 1990 | 19 | 1.89 | 1.52 | 545 | 205 | 160 | | 2*2/0AWG+l*2/0AWG | 7 | 3.5 | 2510 | 7 | 3.5 | 1.52 | 671 | 235 | 185 | | 2*3/0AWG+l*3/0AWG | 19 | 2.39 | 3310 | 19 | 2.39 | 1.52 | 830 | 275 | 215 | | 2*4/0AWG+l*4/0AWG | 19 | 3.25 | 4020 | 19 | 3.25 | 1.52 | 1476 | 315 | 245 | | 2*336.4+1*336.4 | 19 | 3.38 | 6146 | 19 | 3.38 | 2.03 | 1649 | 420 | 325 | |