China Air Load Break Switch manufacturer
Xi'an Xigao Electricenergy Group Co., Ltd.
Xi'an Xigao Electricenergy Group Co., Ltd.
6
Home > Products > Air Load Break Switch >

FN7 Air Load Break Switch

FN7 Air Load Break Switch

Brand Name XG
Model Number FN7
Certification ISO CCC
Place of Origin XIAN, China
Minimum Order Quantity 1 SET
Payment Terms L/C, T/T, D/A, D/P, Western Union, MoneyGram
Supply Ability 2000SET
Delivery Time 7-15 DAYS
Packaging Details WOODEN CASE
Type indoor
Medium vacuum
Standard GB, IEC Standard
Function Switch on and off normal load current
Installation Location power plants
Warranty 12 months
OEM Yes
Package exporting standard package
Rated Voltage 7.2kV, 12kV
Rated Current 400A 630A, 1250A, 1600A, 2000A, 2500A, 3150A
Detailed Product Description

1. FN7 Type 10kv 11kv 12kv indoor air load break switch fuse unit pole mounted lbs

FN7-12 series indoor AC HV load switch is a gas-production HV load switch and fuse combination unit with arc quenching principle.It is applied in three-phase AC 50Hz power system with rated voltage 12kV for breaking the load current and making the short-circuit current.The fuse combination unit can break the short-circuit current and has the function of single-phase fuse three-phase tripping and breaking.It is the ideal selection for protecting the line, equipment and transformer. Its performance meets the requirements of national standards GB 3804-2004 High-voltage alternating-current switches for rated voltage above 3.6kV and less than 40.5kV and GB 16926-2009

 

2. Product parameter

 

Serial No.ItemUnitYFN7-12 HV Load Switch
1Rated voltagekV12
2Rated frequencyHZ50
3Rated currentA630
4Rated short-circuit breaking current of fusekA---
5Rated breaking transfer currentA---
6Main loop resistanceμΩ≤80
7Rated active load breaking currentA630
8Rated short-time withstand current(thermal stability current)/durationkA/s20/4
9Rated short-time withstand current(thermal stability current)/duration of earthing switchkA/s16/2
10Rated peak withstand current(dynamic current)kA50
111 min power-frequency withstand voltage(effective value)to earth,phase-to-phase/isolating fracturekV/kV42/48
12Full-wave lightning impluse withstand voltage(peak) to earth,phase-to-phase/isolating fracturekV/kV75/85
13Mechanical lifeTime2000
14Rated opening operation voltageV---
15Time of switch opening triggered by breaking of fusems---

 

3. Product Characteristics

 

small size

light weight
simple & reasonable structure
small operating force
reliable performance & convenient maintenance

 

4. Service Conditions


(1).Altitude≤1000m;
(2).Ambient temperature-25ºC-+ 40ºC;
(3).The daily average of relative humidity shall not be larger than 95% and the monthly average shall not be larger than 90%:
(4).The ambient air shall not be subject to the obvious pollution such as corrosive or combustible gas and steam;
(5).The site without fire hazards and explosion hazards;
(6).The site that the seismic intensity does not exceed degree 8; the gradient shall not exceed 5°

 

5. Technical detail

 

 

6. Factory

 

 

 

7. Delivery

 

 

8. FAQ

 

1. Send the technical data, better for all useful information; we will make a good recommendation.

If possible please attach one reference picture to avoid any misunderstanding or any links from our website for we get a better understanding.

2. The lead time depend on quantity of order. Some standard type is on stock. Otherwise, it will take 3-15 days.

3. Usually shipped by sea, small order or urgent order we can send you by air.

4. All our activities are accredited to ISO 14001:2015 and IEC standard.

5. Technology ensure the quality satisfy international request.

Product Tags: 7.2kV Air Load Break Switch   12kV Air Load Break Switch   2500A Air Load Break Switch  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Xi'an Xigao Electricenergy Group Co., Ltd.
Subject:
Message:
Characters Remaining: (80/3000)