Durable Automatic Compact Busbar insulation testng Machine With 2
Axis Servo
Suzhou Kiande Electric Co.,Ltd. is a comprehensive scientific
enterprise specialized in intelligent production and data analysis
for electricity manufacturing field. Company’s head office is
located in Suzhou(Paradise on earth) and manufacturing center is in
Zhen Jiang(Chinese electricity island).It covers R&D dept,
design dept., production dept., sales dept. and after-service dept.
which improves to provide better programs for production
efficiency, quality, cost and data.
Function introduction
Automatic Busbar Inspection Line is composed of three parts,
feeding positioning station, inspection station and discharge
station. When the busbar enters the feeding position, the control
system will select the right testing fixture to start testing from
the information identified by bar code or previous assembly line.
Three tests will be performed including HV withstanding test,
insulation resistance test and grounding test. After test is
finished, testing report will be generated. This report can be
saved, printed on site and recorded remotely. Its format can be set
according to customer’s requirements. Automatic inspection machine
is mainly used for batch inspecting on the straight busbar. Elbow
busbar type shall be tested on manual inspection machine.
No. | Parameters |
Model | KD-JCX/NC-E/H-6 |
Busbar Height | 100mm~650mm |
Busbar Length | 1200mm~6000mm |
Busbar Type | Straight length type |
Position Type | Unilateral / Middle |
Working Efficiency | 2 min/piece(testing time is adjustable.) |
Servo Nos | 2 axis( Z axis/X axis) |
Vision System | Phase error judgment( optional) |
Printing System | Bar code printing/ Report printing( optional) |
High Voltage Withstanding Test | 0~5000V |
Insulation Test | 1~1000V |
Grounding Test | 0~25A |
Power | 380~415VAC 50~60Hz 5kW |
Equipment Dimension | L12000mm*W1200mm*H1900mm |