Workshop Ventilation High Volume Low Speed HVLS Ceiling Fan
|
Workshop Ventilation High Volume Low Speed HVLS Ceiling Fan |
| Series | Model | Numbers of the blades | Voltage | Power | Diameter | Drive mode | Max speed | Max air volume | Max coverage area(m²) | Fit for installation height(m) | Noise level | Net weight |
| Fengshen series (Gearbox motor) | DS-7.3 | 6 | 220V/380V | 1.5KW | 7.3M (24FT) | Gearbox motor drive | 50RPM | 888000m3/h | 1200 | 7~18 | ≤60db | 156kg |
| DS-6.7 | 6 | 220V/380V | 1.5KW | 6.7M (22FT) | Gearbox motor drive | 52RPM | 822000m3/h | 1000 | 6~15 | ≤60db | 152kg | |
| DS-6.1 | 6 | 220V/380V | 1.5KW | 6.1M (20FT) | Gearbox motor drive | 55RPM | 774000m3/h | 800 | 6~13 | ≤60db | 147kg | |
| DS-5.5 | 6 | 220V/380V | 1.5KW | 5.5M (18FT) | Gearbox motor drive | 60RPM | 732000m3/h | 600 | 5~11 | ≤60db | 143kg | |
| DS-5.0 | 6 | 220V/380V | 1.5KW | 5.0M (16FT) | Gearbox motor drive | 65RPM | 690000m3/h | 450 | 5~9 | ≤60db | 140kg | |
| Fengxing series (PMSM motor) | DX-7.3 | 6 | 220V | 1.5KW | 7.3M (24FT) | brushless direct drive | 50RPM | 888000m3/h | 1200 | 7~18 | ≤38db | 106kg |
| DX-6.7 | 6 | 220V | 1.2KW | 6.7M (22FT) | brushless direct drive | 55RPM | 822000m3/h | 1000 | 6~15 | ≤38db | 100kg | |
| DX-6.1 | 6 | 220V | 1.0KW | 6.1M (20FT) | brushless direct drive | 60RPM | 774000m3/h | 800 | 6~13 | ≤38db | 94kg | |
| DX-5.5 | 6 | 220V | 0.75KW | 5.5M (18FT) | brushless direct drive | 65RPM | 732000m3/h | 600 | 5~11 | ≤38db | 72kg | |
| DX-5.0 | 6 | 220V | 0.7KW | 5.0M (16FT) | brushless direct drive | 68RPM | 690000m3/h | 450 | 5~9 | ≤38db | 68kg | |
| DX-4.2 | 5 | 220V | 0.6KW | 4.2M (14FT) | brushless direct drive | 75RPM | 636000m3/h | 300 | 4~7 | ≤38db | 64kg | |
| DX-3.6 | 5 | 220V | 0.3KW | 3.6M (12FT) | brushless direct drive | 90RPM | 393600m3/h | 250 | 4~6 | ≤45db | 42kg | |
| DX-3.0 | 5 | 220V | 0.2KW | 3.0M (10FT) | brushless direct drive | 100RPM | 331800m3/h | 200 | 4~5 | ≤45db | 38kg | |
| DX-2.4 | 5 | 220V | 0.15KW | 2.4M (8FT) | brushless direct drive | 100RPM | 273000m3/h | 200 | 4~5 | ≤45db | 34kg |
The chassis is tempered after precision hot forging to ensure the strength and toughness; after CNC processing, dynamic balance detections carried out to ensure the best
stability.
DAISEN's unique design of row holes on the installation plate, can prevent the
sliding of the installation plate, we also have installation kits for concrete and
and circular tube structure as well as any other kinds of structure.
Blader connector,After the precision cold drawing process, the heat
treatment is carried out. After the arc surface is processed, it ensures no gap fit with the blade, and has the largest contact surface with the blade to ensure uniform force.
The galvanized structure steel universal joint,can adjusts the horizontal and vertical direction to ensure the fan in vertical status. So that ensuring the balance of the fan in the process of rotation, and reducing the torsion transmission from the fan to the building.
coupling. ,40Cr alloy coupling, CNC machining to ensure transmission stability
8mm diameter steel rope wrapped with anti-rust plastic,reinforced rope clip,with anti-skip turnbuckle screw tension and adjust the horizon of the fan, prevents shaking of the fan, absorb the vibration energy.
The blade is made of aeronautic Al-mg I alloy material that passed T6 heat treatment process ,it has high strength,high durability
Select high strength screws greater than 8.8 grade according to different
connecting parts of the fan,anti-loosing self-locking screws and and anti-slip nuts ,together with anti-loosing thread glue ,anti-falling connection rings , anti-falling connection parts of the blade.
Permanent magnet synchronous motor (PMSM) ,brushless and directdrive, no gearbox, no transmission lubricating oil, permanent maintenance free,220V 1 0.7KW high efficiency, energy saving, quiet and efficient
DAISEN's unique design of row holes on the installation plate, can prevent the
sliding of the installation plate, we also have installation kits for concrete and and circular tube structure as well as any other kinds of structure.
E9
Poleless speed control box, German Weitu structure design, speed control display panel, France Schneider airs witch over-current overload protection, control box cooling fan assembly, fan status indicator lamp,fan status detection, accidental automatic power cut-off, anti-electromagnetic interference
The blade is made of aeronautic Al-mgalloy material that passed T6 heat treatment process,it has high strength,high durability
Air is gathered at the end of streamlined blades to form eddy current, to prevent cavity whistling, to comply with the principle of fluid mechanics and to generate downward pressure to counteract the reaction force of blade floating up, so as to maintain the stability of blades
8mm diameter steel rope wrapped with anti-rust plastic,reinforced rope clip,with anti-skip turnbuckle screw tension and adjust the horizon of the fan, prevents shaking of the fan, absorb the vibration energy.
Comparison of three refrigeration methods in 1000 square meter plant
| Refrigeration mode | Quantity | Power/unit | Tall power | General comparison |
| Central air conditioner | 1 | 80KW | 80KW | The walls and doors and windows of the plant are required to be insulated. The cost of one-time investment of the equipment is high, and the maintenance cost of replacing the filter element and adding refrigerant is high |
| Traditional industrial fan | 40 | 0.3KW | 12KW | The installation of traditional wall fans is limited by walls and columns. The power lines of floor fans are scattered, which has potential safety hazards. It is not safe for the hair of staff members to be mixed into the fan blades, which occupies a small space and covers a short service life |
| 7.3M large industrial ceiling fan | 1 | 1.5KW | 1.5KW | Large coverage area, long service life, low maintenance cost, installation does not occupy the workshop space, safety and environmental protection |
The energy consumption of large industrial ceiling fan is about 1 / 50 of that of central air conditioner and 1 / 10 of that of traditional industrial wall fan
***Suitable places of installation: Any high enough structure of factory,sport center,logistic place,car repair workshops,supermarket, airport,package workshop,animal breading industry,any kinds of hall,as well as fitness center etc.
***Height of installation: "Fengshen" series products for 6 meters to 20 meters height.
"Fengxing" series products for 3 meters to 6 meters height.
***Solutions for the three main kinds of installation structures as above shown pictures.
DAISNE Workshop overview
Typical customer applications
Certificates of DAISEN CEILING FANS
FAQ
Q:Are you a foreign trade company or a manufacturer ?
A: Yes , we are a manufacturer, Our factory is specialized in HVLS Industrial Ceiling Fans, cooling fan ,Exhaust Industrial Fan and so on.
Q: Can you make my brand on products or provide OEM service?
A: Yes.We provide OEM service.We are the OEM supplier for some famous companies
Q: What's your minimum quantity for order (MOQ)?
A: 1PCS
Q: what's the delivery time?
A: It depends on the order quantity. Delivery time will be within 3days after receiving payment by TT.
Q: What is your terms of payment ?
A: Payment≤10000USD, 100% in advance. Payment≥10000USD, 30% T/T in advance , balance before shipment.
Q: How long is the warranty?
A: we offer 3 years warranty to guarantee the quality for global customers.
|
3.0m (10Ft) 8-Blade Industrial Fan High-Speed High Air Volume Energy Saving Ventilation Cooling PMSM Motor |
|
Ceiling Mounted Traditional Hvls Electric Ceiling Fan with 6 Aluminum Blades Customization |
|
Customizable Industrial Ceiling Fans with Gearbox Motor or Pmsm Motor for Workshop Ventilation and Cooling SGS Certified |
|
Super High Volume Basketball Ventilation Ceiling Mounting Hvls Fan With AC Electric Current Type |
|
AC Electric Current Type Mounting 3m 10FT Hvls Industrial Indoor Exhaust Ceiling Fan with Pmsm Motor |
|
8-24FT Large Industrial Fan for Basketball Ventilation AC Electric Current Type Blade Material Aluminum |