NEW TB811 ORIGINAL MANUFACTURER SHED ABB MODULE
|
NEW TB811 ORIGINAL MANUFACTURER SHED ABB MODULE
Connection to Phoenix Contact Varioface solutions
Phoenix Contact offers solutions for fast termination solutions with pre-wired cables and an assortment of terminations and signal adaptions. This offer connects to S800 I/O via the TU812 termination unit which provides a D-sub connector. Further information is available when following the link www.s800connection.com.
ABOUT US
Cambia Automation Limited, Our company has been established in 2006, retains an extensive inventory of PLC DCS TSI spare parts. We are one of the leading stockiest and supplier of Bently Nevada, Allen Bradley, Honeywell, Triconex, ICS Triplex products in China. Below is our business scope, if you are interested, please don't hesitate to contact us. (Email: sales7@cambia.cn)
-----Rockwell Allen-Bradley
SLC500: 1747/1746 series MicroLogix: 1761/1763/1762/1766/1764 series CompactLogix: 1769/1768 series Logix5000: 1756/1789/1794/1760/1788 series PLC-5: 1771/1785 series
-----Schneider Modicon
Quantum 140series: CPU processor module, Communication module, Analog input-output module, Digital input-output module -----GE IC693/IC695/IC697/IC698/IC200/IC660/IC670 CPU module, Communication module, Analog-digital module EX2100, EX2000 Excitation system card, IS200 series DS200 series
-----Invensys Foxboro
I/A Series system, FBM(input/output modules) sequential control, Ladder logic control, accident recall processing, Digital-to-analog conversion, Input/output signal processing, Data communication, and processing
-----Invensys Triconex
A redundant fault-tolerant control system, the most modern fault-tolerant controller based on triple-module redundancy (TMR) architecture
Contact Me
Email: sales7@cambia.cn (Skype)
S800 I/O Modules
The I/O modules have open ventilated plastic enclosures. On the front of all I/O modules, there are at least three LEDs (FAULT, RUN, and WARNING) indicating the module status. Additionally, some modules have LEDs indicating OSP or PRIMARY, see Table 3 and Table 4.
I/O modules may be replaced in a fully operational I/O station. Mechanical keying on modules and MTUs protect I/O modules from being inserted in positions where they could be damaged by excessive voltage or current. An electronic type designation ID in each module keeps the I/O module from being taken into operation by the ModuleBus master if a module’s ID doesn’t match the configured module type definition. There are modules for both single and redundant applications.
Advantage products
Main Brand
Invensys( 4329, 3805E, 3503E,3721,3636T,DO3401,3625)
|