AC220V Electric Coolant Transfer Pump For Glycol Circulating On Thermal Management System
|
AC220V Electric Coolant Pump For Glycol Circulating on Thermal Management System.
Product features Product name:BLDC Electric Water Pump Model:OWPA650L-1 Service life: 40000hrs IP grade: IP67 Appearance: Aluminum alloy natural colors Bracket: All-in-one Noise: ≤65dB(A) Tightness: At 0.4Mpa, the leakage<1ml Weight: 2.7Kg Flame retardant: According to GB/T 2408 standard, it meets the horizontal combustion HB level and the vertical combustion V-0 level Mechanical strength: According to QC/T413-2015 standard, Meets Severity Rating: On Engine Prohibited substances: Meets GBT 30512-2014
The scope of use Ambient temperature: -40—85℃ Liquid temperature: -40—85℃ Liquid type: Commercial coolants can be used with water pumps, but mixing different coolants is not allowed. The mixing ratio of water and antifreeze is selected in a range of 50/50 to 40/60. In order for the cooling system to be completely filled with media, the cooling system must be completely drained to a vacuum. Installation: Vibration and noise requirements must be taken into account in the definition of the installation location and specific fixing elements/fasteners in the application, and the installation position must avoid water accumulation on the surface/inside the connection system. Typical applications: Energy storage thermal management system, liquid-cooled charging cabinet, data center system
Basic parameters: Rated voltage: 220VAC Operating voltage range:170~275VAC Current rating: 3.5±5% A Rated performance: 120L/min@180Kpa Input power: 700W±5% BEMF: 24.5±3%V Number of pole pairs: 3 pairs of poles Insulation rating: F Electrical strength: <1mA >500MΩ Harness length: U V W Power cord length 300mm Plug-in information: Amphenol:AT04-3P-RD01-NFK Maximum flow rate: 180±5% L/min Maximum head: 23±1 m Speed range: 2500rpm~5500rpm Resistance: 2.6±3%Ω Inductance: Axis-Q 14mH Axis-D 13mH
Protection and fault feedback function description
In order to ensure the normal operation of the pump, the controller adapted to the pump needs to meet the following protection functions.
Pump installation size 6. The performance of the pump
Schematic diagram of the test bench |
Product Tags: AC220V electric coolant transfer pump Glycol Circulating electric coolant transfer pump AC220 V coolant pump electric |
![]() |
High Head Pressure 600Kpa Mini Coolant Pump Electric For EV Charging Devices' Cooling |
![]() |
AC 220V Electric Antifreeze Pump For Liquid Cooled Of Battery |
![]() |
OWPA650L-1 700W Electric Coolant Pump For Industrial Cooling Equipment |
![]() |
220V AC Input IP67 Electric Coolant Pump For Energy Storage Cooling System |
![]() |
Bextreme Shell DC48V BLDC Electric Coolant Pump For Glycol Circulation |
![]() |
OWPD650B-1 IP67 Stainless Steel Coolant Pump Electric For Liquid Cooled In Data Center |