Mining Farm Server Immersion Cooling System Introduction of two-phase liquid cooling: - The cooling liquid undergoes a phase change in the process of
circulating heat dissipation. The cooling liquid takes away the
heat from the server and then undergoes a phase change
gasification. The gaseous cooling liquid is condensed by the
condenser and becomes liquid again and returns to the liquid
cooling tank; the cooling liquid can use 3M electronics The boiling
point of the coolant FC-72 and FC-72 is above 50℃.
- In this case, the temperature of the water in the condensing coil
does not need to be too low. The use of a dry cooler can meet the
heat exchange requirements and take away the heat. The two-phase
liquid cooling has a high heat transfer efficiency due to the phase
change of the electronic cooling liquid.
- The disadvantage is that during this phase change, the electronic
fluorinated liquid will escape during the vaporization process, so
there is a certain degree of tightness of the container. However,
it should not be too sealed to prevent the cooling system from
being interrupted and the cylinder explosion event, so certain
safety facilities need to be set up.
Features - Our range of Dry Air Coolers and Radiators are designed for
commercial and industrial fluid cooling applications.
- We offer a wide range of options to provide the most
cost-effective solution for your cooling requirement.
- Standard arrangements include flat-bed vertical or horizontal
airflow with V configurations to offer the smallest footprint.
- Whether your application is cooling water / glycol for water cooled
chillers, injection moulding machines, furnace equipment, CHP
Engine Cooling or any other process. One or more of our units can
be selected to provide the most cost-effective solution to
suit your space and noise requirement.
- Energy saving free cooling is possible for much of the year for
many applications.
Material options | Heavy-gauge hot-dip galvanized steel is used for unit steel panels
and structural elements featuring a zinc aluminium coating. | Heat transfer media: | A. The dry cooler is constructed of staggered and seamless copper
tubes (15,9 or 12,7 diameter) with aluminium, rippled and
corrugated fins (0,14 or 0,17 thickness). | | B. 2.5 mm fin spacing for optimal air turbulence | | C. Thick and seamless copper headers and threaded steel connections | | D. Pressure tested at 30 bar | | E. Try our options for aggressive environments: special pre-coated
anti-corrosion aluminium fins or copper fins (0,2 mm thickness). | Air movement system: | A. Axial fan with exceptionally compact direct drive short
integrated motor and fan guard. | | B. The fan features an impeller and motor and is balanced as a
complete unit using dynamic single plane balancing. Balance grade
is G6.3. | | C. Fan and motor totally maintenance free. | | D. Bearings seals and motor encapsulation for long service life. |
Why choose us: - We can help buyers design specific products or produce products
according to buyers' design
- We can print logo according to buyers' requirement
- We has exported to many countries,such as Singapore, Philippines,
Vietnam, Argentina, Peru, Mongolia, Hong Kong, UAE,Russia, Poland
etc.
- Design term: We have professional design team.
- Professional factory: We are manufacturer, specializing in
manufacturing heat exchangers for over 16years, competitive price
with good quality.
- Rapid response to your needs: We will reply within 24 hours after
receiving you letter. If you have urgent thing, welcome to call us.
- The Most Efficient Service, Best Quality and Excellent Reputation.
Technical Paraments Flat series — Double rows fans H*FD*91 | Fan Dim mm | * | H*FD491 | H*FD691 | H*FD89 | H*FD1091 | H*FD1291 | H*FD1491 | H*FD1691 | H*FD1891 | Rated Capacities (kW) Heat Exchange Surface (㎡) | Fluid Coolers | 910 | D | 237kW-1632kW 454㎡-4903㎡ (Water/Ta25℃/Tin40℃/Tout35℃) | Freon Condensers | 910 | F | 285kW-1632kW 454㎡-4903㎡ (R404A/Ta35℃/Tk50℃) | Ammonia Condensers | 910 | A | 151kW-1709kW 263㎡-5696㎡ (NH3/Ta35℃/Tk50℃) | Gas Coolers | 910 | G | 156kW-1929kW 358㎡-3859㎡ ( CO2/Tair32℃/Tin113℃/P94Bar/Tout34℃) | Oil Coolers | 910 | O | 174kW-2212kW 454㎡-4903㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃) | Fan Model | 910 | EC | W3G910KU2503 (2.55kW) or FN091-ZIQ.GL.V5P1 (3.2kW) | 910 | AC | W6D910GB0101 (2.02kW) or FN091-SDS.6N.V7P2 (1.85kW) | No of Fans | 4 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | Overall Dimensions | 910 | Lenth-1 | 3480 | 4980 | 6480 | 7980 | 9480 | 10980 | 12480 | 13980 | Lenth-2 | 4080 | 5880 | 7680 | 9480 | 11280 | 13080 | 14880 | 16680 | Width | 2265 | Height | 1740 (Including 800Leg) |
Options Coil design refrigerant: water, oil, glycol | Multiple circuits | Sub-cooling circuits | Stainless steel or aluminum casing | Coated aluminum or copper fins | Explosion proof motor | Customized fin spacing | |
Reference: For data center cooling | Country: Mongolia Application: match with precision air conditioner Cooling capacity: 17.6kW Cooling medium: 34% ethylene glycol Supply power: 400V/3P/50Hz Fan brand: Ziehl-Abegg | Country: Russia Application:data center cooling Cooling capacity: 763kW Cooling medium: water Supply power: 380V/3P/50Hz Fan brand: Ziehl-Abegg | | | For power plant | Country: Hongkong Application: power plant Cooling capacity: 363kW Cooling medium: water Supply power: 415V/3P/50Hz Fan brand: Chinese brand | Country: Russia Application: power plant. Cooling capacity: 180kW Cooling medium: water Supply power: 380V/3P/50Hz Fan brand: Chinese brand | | |
|