Wall Mounted Fan Coil FCU For Data Centres Free Cooling System

Brand Name Shenglin
Model Number SL-ZKW Series
Certification /
Place of Origin China
Minimum Order Quantity 1
Price 500~4000USD/unit
Payment Terms T/T, Western Union
Supply Ability 100 Units Per Month
Delivery Time 35~40days
Packaging Details Plywood wooden box or pallet
Supply power 220V / 50Hz.
Compressor type No compressor
Air cooled or water cooled Fresh air cooled
Feature Has free cooling valve
Mounting Wall mount
Fant type EC fan
Detailed Product Description

Wall Mounted Fan Coil FCU For Data Centres Free Cooling System

 

Features:

1. The maximum air flow of at least 2000 m3 / h.
2. Minimum airflow is not more than 700 m3 / h.
3. Power supply 36-56 VDC (direct current).
4. Power consumption at the maximum air flow isn’t more than 300 W.
5. Power consumption at a minimum flow of air isn’t more than 20 W.
6. The power of the electric heater at least 1.5 kW, voltage 220V / 50Hz.

 

Technical Data:

Structure:

FCU should has:
1. Insulated body and the valve free cooling for inadmissibility through freezing at outdoor temperatures down to - 40 ° C by the cold climate zone, and up to - 20C in the performance for the warm climate zone;
2. Free cooling valve actuator with analog control, which allows smoothly change the position of the valve;
3. Air filter cassette-type, folding to replace the filter element, contamination control system;
4. Mosquito protection (pre-filter);
5. The prevention of access of outside air, controlled by a signal fire system;
6. Control system aerodynamic resistance cleaning filter (air flow pressure sensors at the inlet and outlet filters);
7. Electric heater, controlled by the controller (as an option).
8. FCU should has double filter which can protect BS from dust

 

Application:

Data centres or IT environments in colder climates.

 

Product Tags: 2000m3/H FCU AC Unit   2000m3/H Clean Room Air Conditioning System   FCU Clean Room Air Conditioning System  