SUS304 Water Tank Water Cooled Industrial Chiller CE With Micro Controller

Brand Name Shenglin
Model Number SJ Series
Certification CE
Place of Origin China
Minimum Order Quantity 1
Price 999~70000 USD/unit
Payment Terms Western Union, T/T
Supply Ability 100 units per month
Delivery Time 30~35 days
Packaging Details Plywood wooden box
Refrigerant R22 or R404A
Compressor Imported compressor from Europe,US and Japan
Warranty One year after leave the factory
Water outlet temperature 10 ℃
Condenser type Shell and tube heat exchanger
Evaporator type Shell and tube heat exchanger
HS code 8418692090 or 84186990
Controller Micro-computer or PLC(optional)
Packing way Plywood wooden box
Keyword Industrial Chiller
Detailed Product Description

R22 Or R404A Water-cooled Industrial chiller
 
Industrial Chiller Features:
High/Low pressure protection for the compressor and overheating protection inside the machine. Low water level alarm and low temperature alarm. Imported compressor from Europe,US and Japan.Refrigerating system welded with oxygen free method, to reduce oxides and ensure the smooth surface.Throttle components from Danfosss(Denmark) and Alco(US). SUS304 stainless steel water tank, to avoid corrosion or water leak.
Stainless plate, coil, shell, and tube or fin type efficient heat exchanger. RS485 communication function, to realize automatic management(optional). Electrical devices supplied from OMRON, FUJI.TE,LG,MOELLER and SCHNEIDER. Control mode:imported micro-computer or PLC(optional) Perfect safety protection, failure display, and not requiring professional personel for maintenance. Highly efficient evaporator and conderser, to save over 30% energy. 2 compressor heads for over SJ-10WD, for individual or joint operation
 
Technical parameters table of Water-cooled Industrial chiller:

Model
parameter
SJ-20WDSJ-25WDSJ-30WTSJ-36WTSJ-40WFSJ-50WFSJ-60WF
Cooling capacityKW(50HZ)667699114132152198
Kcal/h56760653608514098040113520130720170280
motor inputKW15.41723.62630.233.539.6
Maximum CurrentA29.631.845.648.658.362.376.2
Power Supply3N 380V/415V 50HZ
RefrigerantNameR22
Charge(KG)5*26.3*25*36.2*35*46.2*45*6
Control Type       
CompressorType       
Motor(KW)6.6*27.4*26.6*37.4*36.6*47.4*46.6*6
Cooling WaterFlow(m3/h)15.918.221.3227.331.736.447.5
In/Out Pipe SizeG2"G2"G2-1/2"G3"G3"G3"G3"
 Flow(m3/h)11.313.117.0619.722.826.234
 Tank(m3)0.280.40.40.40.550.3
Chilled WaterIn/Out Pipe SizeG2-1/2"G2-1/2"G2-1/2"G3"G3"G3"G3"
Water PumpMotor(KW)2.22.23.753.753.753.75
Pressure(Kpa)220220250250250250250
SizeLength(mm)1680188022002200240024002400
Width(mm)77591410001000100010001150
Height(mm)1480165016501650165016501650
Weight(KG)KG44058069076090010001000

Cooling capacity reference: inlet 15℃ cold water, outlet 10℃ cold water, inlet air temperature 35℃.

We reserve the right to make changes to the above specification without notification.
 
Application:
 
Plastics IndustryPrinting IndustryMedical Industry


 


 

Laser Cutting IndustryBrewery IndustryChemical Industry



Food IndustryIce Rink IndustryHVAC industry


 


 

 
Overseas project:

FAQ:
 
1. How does a chiller system work?
Chiller has two circulation,one is process water circulation,the other is refrigerant gas circulation.Heat picked up from the process.Heat transfers to refrigerant circulation.Heat is remove to air or water.
 
2. How to calculate cooling capacity for chillers
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86
Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
 
3.Types of industrial chiller system?
Air Cooled Chiller and Water Cooled Chiller.Water cooled chiller needs a separated cooling tower and has a higher efficiency,but less easier than air cooled.
 
4. Cooling capacity unit conversion?
1 kcal/h = 1.163W,1 W = 0.8598 kcal/h
1 Btu/h = 0.2931W,1 W = 3.412 Btu/h
1 USRT = 3.517 kW,1 kW = 0.28434 USRT
1 kcal/h = 3.968 Btu/h,1 Btu/h = 0.252 kcal/h
1 USRT = 3024 kcal/h,10000 kcal/h = 3.3069 USRT
 
5. The industrial chiller can heat?
Yes,by the electrical heating wire.Please kindly inform us the hot water temp or heating capacity.
 
6. Industrial chiller maintenance?
Step 1: Keep Tubes Clean
Step 2: Ensure a Leak-free Unit
Step 3: Sustain Proper Water Treatment(prevent scale, corrosion)
Step 4: Analyze Oil and Refrigerant
 














































Product Tags: sus304 water cooled industrial chiller   SUS304 water cooled liquid chillers   SUS304 water cooled industrial chillers  