Combined Floor Mounted 50000m3h Clean Room Air Conditioning System
|
Easy Installation Combined Type Air Handling Unit The combined air handling untis are modular designed ,each modular
can be used independently and can also work together and company
with fan coil units to add refresh air. Not only reduce operation
costs and energy saving, but also optimize air quality and create a
congnitive indoor space to meet the human health requirements. Products Features 1. Aluminum frame structure, high mechanical strength, light weight, corrosion resistance, good-looking appearance, accurate sizes. Flexible assembly structure, easily assembly and maintenance, service life is longer than the steel frame. 2. Double skin polyurethane color steel panel, no cold bridges. 3. Double air inlet centrifugal fans, by the strict dynamic and static balance test, smoothly running, small vibration. Closed rolling bearing, automatically aligning and automatically self-locking, anti-push and other functions, pre-filled with lubricating oil, normally use without maintenance. 4. Plate filter can be cleaned many times. 5. Has function of air supply, cooling, heating, dehumidifying, humidification, air filtration and noise reduction etc. 6. Suitable for the air conditioning system for electronics, instrumentation, machinery, metallurgy, chemical industry, textile, medicine, food, tobacco, transportation, energy and other industries.
Optional installation accessories Air valve Air duct Air grill Technical Data: Chilled Water Air Handing Unit Spec. Table No. 2
indoor dry bulb/ wet bulb temp35/28℃, fresh air dry bulb/ wet bulb temp35/28℃ 2. Heating condition conditions: supply and return water
temp60/50℃, 3. The air volume, residual pressure and power in the table are
standard parameters, 4. Heater, humidifier and heat recovery device are optional, which can be configured as spacific form according to customer's requirements 5. G4 filter is adopted as the unit standard, which can be configured as other form according to customer's requirements 6. The length and size are determined by the functional sections. Please consult us for details.
Application: The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: 30KW Clean Room Air Conditioning System 50000m3h Clean Room Air Conditioning System 50000m3h Air Handling Units |
![]() |
Microorganism Reduction Sanitary Hygienic AHU Clean Room Air Conditioning System |
![]() |
Hygienic Air Handlers For Food Processing Rooms And Critical Process Areas |
![]() |
Modular AHU Clean Room Air Conditioning System Floor standing |
![]() |
Cleanroom HVAC System Fresh Air Package Type Air Handling Unit AHU |
![]() |
ISO14001 Standard Clean Room Air Conditioning System Air Handler |
![]() |
Ceiling Mounted Chilled Water Air Handling Unit In Pharmaceutical Industry |