Aloka ALPHA5 Board EP476000BB Ultrasound PCB Board 1.Part number:EP476000BB 2.Pre-owned original one ,in excellent condition 3.We provide 60 days warranty Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are
within our repair/ maintenance range. Other ultrasound parts related to Aloka that we can offer: Brand | Machine type | Description | Aloka | Alpha 5 | Main board EP493700DD | Aloka | Alpha 5 | Main board EP481200DD /EP525200 | Aloka | Alpha 5 | Contral board | Aloka | Alpha 5 | EP496700BB,EP496800BB | Aloka | SSD-3500/Alpha 5 | EP531900AA | Aloka | Alpha 5 | EP512600AC | Aloka | Alpha 5 | EP444300LR | Aloka | Alpha 6 | CPU board EP537000AB/EP5630 | Aloka | Alpha 6 | Power supply EU6046 | Aloka | Alpha 6 | Contral board L-KEY-105B | Aloka | Alpha 6 | Alpha 6 number keyboard | Aloka | Alpha 6 | Touch screen | Aloka | Alpha 6 | LCD | Aloka | Alpha 6 | RX Beam Former EP555501AA | Aloka | Alpha 6 | EP555300 | Aloka | Alpha 6 | EP550000AA | Aloka | Alpha 6 | CW Board EP555700 | Aloka | Alpha 6 | 3D/4D Board EP556000 | Aloka | Alpha 6/Alpha 7 | RXBF & TP Board EP555500 | Aloka | Alpha 7/Alpha 6 | BEAM FORMER Board 554101BB | Aloka | Alpha 7 | RX Board EP539100BB | Aloka | Alpha 7 | DBF&TXRX CONTROL BOARD Rx Beam Former EP539500 | Aloka | Alpha 7 | Rx Beam Former EP539501 | Aloka | Alpha 7 | Probe interface board EP539000 | Aloka | Alpha 7 | TX BOARD EP548300BB | Aloka | Alpha 7 | Connector Assy EP540100 | Aloka | Alpha 7 | contral Board EP545100CC |
Knowledge Point Aloka Alpha 5 1.Technical Features Advanced front-end information acquisition technology: Alpha 5 uses highly integrated digital front-end technology (HDDF)
and the new α series probe, as well as PST pure beam emission
technology. These technologies work together to provide excellent
image quality. PST pure beam emission technology eliminates unnecessary signal
components by controlling the sound beam and only emits the signals
required for imaging, thereby enhancing the sensitivity and
resolution of fundamental and harmonic imaging. Highly Integrated Digital Front-end (HDDF): Thanks to Aloka's advanced microelectronics technology, Alpha 5 has
developed a unique high-speed ultrasound signal processor that can
collect and process weaker signals from tissues. Alpha 5 can achieve better resolution and penetration in both
high-frequency and harmonic states. High-speed front-end data stream processing (HR-FSB): Alpha 5 converts all received information into 12-bit digital
signals, greatly improving dynamic range and sensitivity. New α series probe: Combined with the latest materials science and probe cutting
technology, Alpha 5's probe enhances the sharpness of the sound
beam and improves image quality. Built-in intelligent information management system (iDMS): Patient data and images can be easily managed, and multiple formats
such as DICOM, JPEG, BMP or TIFF can be supported for storage and
transmission. Doctors can listen to Doppler sounds in B mode, or perform
post-processing analysis on images after the patient leaves. Fine tissue harmonic imaging technology: Alpha 5's integrated pure beam emission technology reduces acoustic
wave deformation and noise signals in harmonic imaging, and wide
aperture emission improves the resolution of harmonic imaging. The latest generation of contrast harmonics is suitable for
real-time contrast imaging at low sound pressure. It uses Aloka's
unique contrast technology to extract only the harmonic information
generated by the contrast agent, and observe the contrast agent
perfusion in real time for a long time. Blood flow profile technology: Through this technology, doctors can easily obtain the blood flow
velocity at each point on the entire vascular profile, thereby
accurately calculating the blood flow of the blood vessel. This
technology can also be used to calculate cardiac output. Tei index component: It provides accurate, simple, easy and repeatable measurement
analysis and reporting functions for random analysis of overall
cardiac function changes in cardiac contraction and diastole. 2. Clinical Application Alpha 5 has a wide range of clinical applications and can be used
to diagnose a variety of diseases, such as tumors, cardiovascular
diseases, gynecological diseases, etc. By observing and analyzing
ultrasound images, doctors can determine the location, size,
morphology and other characteristics of the lesion, providing a
basis for formulating treatment plans. At the same time, it can
also be used for real-time ultrasound image guidance during
surgery, as well as monitoring and evaluation of changes in
patients' conditions. Various Ultrasound Systems that we served GE Ultrasound System | LOGIQ P5, LOGIQ P6, LOGIQ S7, LOGIQ S8, VOLUSON 730, VOLUSON 730
PRO, VOLUSON 730 EXPERT, VOLUSON S8, VOLUSON P8, VOLUSON S6,
VOLUSON S20, VOLUSON P8, VOLUSON E10, VIVID E9, LOGIQ BOOK, LOGIQ
5, LOGIQ 7, LOGIQ 9, LOGIQ E9, LOGIQ F6, LOGIQ F8, VIVID I, VIVID
Q, VOLUSON I, VOLUSON E, VIVID S5, VIVID 3, VIVID 7... |
Ultrasound System | HD11, HD11XE, HD15, HD7, ENVISOR C, IU22, IE33, EPIQ 5, EPIQ 7,
AFFINITI 50, AFFINITI 50G, AFFINITI 70, CX30, CX50, CLEARVUE 550,
CLEARVUE 650, CLEARVUE 850... |
Hitachi-Aloka Ultrasound System | F31, F37, SSD-3500, SSD-3500 SV, SSD-4000, SSD-5000, ALPHA 5, ALPHA
6, ALPHA 7, ALPHA 10, PROSOUND F75, HI VISION AVIUS, HI VISION
PREIRUS, EUB-5500, EUB-6500, EUB-7500, EUB-8500, Arietta 60,