GE 4C Convex Array Ultrasound Transducer Probe Diagnosis Machine
|
GE 4C Convex Array Ultrasound Transducer Used Probe Use in Hospital Diagnosis Machine
Parts of GE probes we can offer:
Knowledge Point
Color Doppler flow imaging
Color Doppler flow imaging system can simultaneously display B-type image and Doppler blood flow data (blood flow direction, flow velocity, flow dispersion) of dual ultrasound scanning system. Color power angio(CPA) detected the backscattered energy of blood cells in the blood flow, which did not distinguish the flow direction, and had nothing to do with the angle θ (the angle between the direction of sound wave and the direction of blood flow). CPA can improve the sensitivity of blood flow detection, especially suitable for displaying low-speed blood flow of small vessels, but can not show the direction of blood flow.
Harmonic imaging
Harmonic imaging exploits non-linear propagation of ultrasound through the body tissues. When the frequency of emitted sound wave is f 0, the frequency of echo (due to reflection or scattering) includes f 0 (called fundamental wave), 2f 0, 3F 0 and so on The second harmonic (2f 0) has the largest energy. Ultrasonic harmonic imaging (UHI) is based on the information of human body carried by the second harmonic in echo (reflection or scattering). Harmonic imaging without UCA is called native harmonic imaging or tissue harmonic imaging. Harmonic imaging using UCA (ultrasound contrast agent) is called contrast harmonic imaging.
Which tests require fasting and which require holding in urine?
Organ examinations require fasting: liver, gallbladder, pancreas, spleen, renal blood vessels, abdominal aorta, etc. Because on the one hand, food will cause the gallbladder to contract and empty bile, the structure and shape of the gallbladder will be affected by ultrasound after the gallbladder contracts. On the other hand, the abdominal contents and gastric gas after eating will be affected, and some ultrasound sections will not show clearly. It is easy to misdiagnose or miss the diagnosis and delay the condition.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Tags: Convex Array Ultrasound Transducer Probe GE 4C Ultrasound Transducer Probe |
![]() |
Medical Instrument GE 12L Linear Array Probe Used Transducer Surgical Equipment |
![]() |
GE 7L-RC 12MHz Wide Band Linearx Used Ultrasound Probe Medical Hospital Instrument |
![]() |
GE IC9-RS Endocavity Ultrasound Transducer Probe Ultrasound Machine |
![]() |
GE RAB4-8-D Wideband Curved Transducer Convex Array Ultrasound Probe Medical Scanner |
![]() |
GE RAB4-8-D Wideband 2-8MHz Convex Array Ultrasound Probe For Abdomen Obstetrics Gynaecological Scanning |
![]() |
Vivid S60 S70 Convex Ultrasound Transducer Probe GE C1-6-D |