China Ultrasound Repair Service manufacturer
Guangzhou Rongtao Medical Tech LTD.
To be the top preferred ultrasound service company worldwide!
5
Home > Products > Ultrasound Machine Repair >

Cow Scanner Ultrasound Machine Repair Siemens S1000 Cardiac Transducer Maintenance

Cow Scanner Ultrasound Machine Repair Siemens S1000 Cardiac Transducer Maintenance

Brand Name Simens
Model Number Simens S1000
Price Negotiable
Payment Terms T/T,Western Union
Delivery Time 2-4 work days
Packaging Details Neutral Package
Category cow scanner
Description digital radiography detectors
System function of ultrasound machine
Warranty 60 days after fixed
Condition Siemens S1000 healthcare equipment supplies
Purpose ultrasound
Detailed Product Description

 Simens S1000 Cardiac Transducer Maintenance

Simens S1000 System Reports Error

 

 

 

Failure phenomenon


Siemens S1000 color super machine, the boot into the ultrasonic working interface is normal, the heart probe is used normally, but the superficial probe and the abdominal probe can only be used normally in the 0B mode, can not be used in other modes, the machine has a card screen phenomenon at the same time.

 

 

 

 

 


 

 

 

 

Failure analysis


The signal processing and control module of S1000 color supercomputer is mainly composed of probe interface module, input and output module and electronic system module. The electronic system module includes TR, CB, RC, BE, VI and RM board, TR, RC board and probe interface module ( The TI Module) performs the ultrasonic signal processing functions together, collectively referred to as the front end portion; the BE, VI, and RM boards are responsible for the subsequent processing of the ultrasonic signal data and the overall control functions of the machine, collectively referred to as the back end portion. The power supply consists of four sections, an AC AC power box, a PSA analgo power module, a PSD digital power module, and a QuickStart Battery.

Firstly, if the system software error occurs, the fault occurs. After the system is reinstalled, the fault still exists, and the system software fault may be eliminated. The problem of RC and BE is initially judged from the hardware function. As the real-time control board of the front end, the RC board is also responsible for the control function of ultrasonic transmission and reception. It is also responsible for analgo-to-digital conversion of the 192 channels of received data of the TR board, thereby converting the echo signals into digital signals, which is convenient for the back-end software. Further processing of the technology. A failure of the RC board will cause all other functions of the machine to be abnormal. The BE board receives the digitized echo signals from the front RC board and processes them according to the operator's requirements. The failure of the BE board often causes one of the functions of the color Doppler to be abnormal.

The PSA and TI can be considered by the hardware replacement exclusion method to eliminate the BE and RC failures. The TI board can support 3 probes at the same time and can be switched at will, but the probe hot swap is not supported. When the TI board fails, it will cause the 2D area to have no image, card screen or boot code "US_IMG_17" and other error codes. The PSA is responsible for the front end power supply and provides the probe working voltage. If the PSA fault will cause the probe to be caused by the abnormal voltage supply. The function is not working properly.

 

 

 


Thoubleshooting


Replace the PSA power supply, all the functions of the machine are used normally, and the fault is eliminated.

 

 

 

 

Ultrasound parts that we can repair:

 

 

Repair List of Featured Ultrasonic Board & Assy
BrandSystemDescriptionPart Number
GELogiq P5CPU mainboard5168431
GELogiq P6CPU mainboard 
GELogiq E9/vivid E9GFI25161631
GEVoluson E6/Voluson E8RSRKTI301394-2/KTI196357
GEVoluson E6/Voluson E8RFI/ RFI21b BoardKTI300614/KTI302197-6
GEVoluson S6/S8/P8BF645396937-2
GEVoluson S6/S8/P8RFS board5364098-2/5364098-3
GEVoluson S6/S10/P8BF192 board5357234
AlokaAlpha 5mainboardEP493700DD
AlokaAlpha 6RX Beam FormerEP555501AA
AlokaAlpha 6CW boardEP555700
AlokaAlpha 6CPU mainboardEP537000/EP563000
AlokaAlpha 6TX/RXEP555300
AlokaAlpha 6/Alpha 7DOMEP550000AA
AlokaAlpha 10RX Beamformer boardEP531800CE
AlokaAlpha 10wave generator BoardEP495000HH/EP495000HJ/EP495000FF
HitachiF37TX/RSEP557400/EP557300
HitachiF37mainboardEP575700BC/EP560800
AlokaF75USP boardEP556600
AlokaF75Cell BoardEP558800
HitachiHI VISION AviusRDBF board7513907A/7513612
HitachiArietta 60CELLEU-9160C
HitachiArietta 70TXEP572300AA
HitachiArietta 70CELL 
HitachiNoblusCELL 
HitachiNoblusCONT-B 
HitachiAscendusCELL7352830A
SiemensX150/G40BE10131804
SiemensX300BE 2.0/BE 3.0/BE 7.510131990
SiemensX700BE10136465
SiemensX700RC10136467
SiemensX700TI11014292
SiemensAntaresBE7472421
SiemensAntaresCB7288504
SiemensS2000RM30010852163
SiemensS2000 high version/S3000RM30110854749
 iU22/iE33EMB excelsior motherboard453561419431/453561382231/453561419431
 iU22/iE33UMB Unified Motherboard453561254492/453561360251
 HD15ACB acquisition control board453561197145/453561197144
 HD15AIM board4.53561E+11
 CX50control panel4.53562E+11
 CX50mainboard453561368033/453561622163/453561495832
 Affiniti 70ACQ acquisition control board 
 EPIQ 5/EPIQ 7ACQ Acquisition Module board453561734844/453561704246
BiosoundMylab SeriesCPU mainboard9501361000
ToshibaAplio 300/400/500mainboardPM30-38696
ToshibaAplio 500RXywm2056*a
ToshibaXario 200TXPM30-32732-1
ToshibaXario 200RXPM30-32733-1
Remarks
1.The repair cycle is within 3-5 days.
2.Warranty after fixed:60 days.
3. Kindly send us the estimated main faults (better to have image) for our engineer to prejudge.
4.Package price is available if repair 3 pcs or more at one time.
5.Extra discount for VIP partners.
6.You could have different part No.under same description.


Product Tags: Cow Scanner Ultrasound Machine Repair   Simens S1000 Ultrasound Machine Repair   Cardiac Transducer Ultrasound Machine Repair  
Related Products
Email to this supplier
 
From:
Enter your Email please.
To: Guangzhou Rongtao Medical Tech LTD.
Subject:
Message:
Characters Remaining: (80/3000)